1. Place log #1 (ember bed) onto the base. Position the log over the shoulder bolts on either side of the front burner. The log will sit on top of the front burner (see Figure 28).

2. Place log #2 behind the back burner and onto the two back tabs as shown in Figure 29.

3. Place log #3 on the left side of the base. It will wrap around the front end of the back burner and fit over the tab at the front of the base (see Figure 30).

4. Place log #4 onto the pins on the right side of log #1 and onto the tab on the base in front of log #2 (see Figure 31).

5.Place log #5 crossing over log #2 and log #1 as shown in Figure 32.

Figure 30 - Installing Log #3 (Model LGX3924NT Shown)

Figure 28 - Installing Log #1 [Ember Bed] (Model LGX3924NT Shown)

Figure 31 - Installing Log #4 (Model LGX3924NT Shown)

Figure 29 - Installing Log #2 (Model LGX3924NT Shown)

Figure 32 - Installing Log #5 (Model LGX3924NT Shown)

For..com

108114

Image 17
Contents What to do if YOU Smell GAS International OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Product Identification Optional Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationSee Between 8 Minimum Noncombustible Material ClearancesMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Remote-Ready Models OnlyConnecting to GAS Supply External Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing Log #2 Model CGX3930NT Shown Installing LogsInstalling Log #3 Model VGX30NT Shown Models LGX3924NT and LGX3924PT Installing Log #3 Model LGX3924NT ShownOperating Heater Attaching Grate to Base AssemblyAdding Lava Rock Lighting InstructionsShutting Off Burners Only pilot stays lit To Turn OFF GAS to ApplianceShutting Off Heater Thermostat Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Flame Thermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrcta Series OperationFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbWiring Diagram SpecificationsService Hints Technical ServiceIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListTHERMOSTAT-CONTROLLED VGX24NT, VGX24PT VGX30NT, VGX30PT29 Parts Available not Shown THERMOSTAT-CONTROLLEDCGX3924NR, CGX3924PR REMOTE-READY LGX3924NT, LGX3924PT KEY Part Number LGX3924NT LGX3924PT Description QTY Accessories Replacement PartsOwners Registration Form International For . .com Not a UPC

INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER specifications

The Desa International Unvented (Vent-Free) Gas Log Heater stands as a remarkable solution for those seeking an efficient and aesthetically pleasing heating option for their homes. Recognized for its innovative design and advanced technology, this heater offers numerous benefits that cater to both functionality and style.

One of the main features of the Desa gas log heater is its vent-free design. This characteristic eliminates the need for ductwork or exhaust systems, allowing for easy installation in various locations, including living rooms, bedrooms, or recreational areas. With no external venting required, homeowners can enjoy increased flexibility in placement while saving on installation costs and labor. Moreover, the heater can fit seamlessly into existing fireplaces, creating a cozy ambiance without the need for traditional firewood.

Another standout feature of the Desa vent-free gas log heater is its exceptional energy efficiency. Utilizing infrared technology, the heater converts a high percentage of gas to heat, warming spaces quickly and reducing energy consumption. The unit is designed to operate with natural gas or propane, offering versatility depending on the homeowner's fuel preferences.

Safety is a top priority in the design of the Desa gas log heater. Equipped with an automatic shut-off system and an oxygen depletion sensor, the heater ensures secure operation by shutting down in case oxygen levels drop too low. This added safety feature provides peace of mind for families, allowing for safe use even during extended periods of operation.

Aesthetically, the Desa International gas log heater does not compromise on style. With an array of realistic log designs and finishes, homeowners can choose a heater that complements their interior decor perfectly. The unit’s flame effects mimic traditional wood-burning fires, enhancing the warm ambiance of any room.

In conclusion, the Desa International Unvented (Vent-Free) Gas Log Heater offers a unique combination of efficiency, safety, and aesthetics. Its vent-free design allows for flexible installation, while infrared heating technology ensures quick warmth and energy savings. Coupled with enhanced safety features and an attractive appearance, this gas log heater provides a practical and stylish heating solution for any home.