CLEANING AND MAINTENANCE

CLEANING AND

MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burners, and circulating air passageways of heater clean. In- spect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to exces- sive lint from carpeting, pet hair, bedding material, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figures 46 or 47).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 48). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector

Holder

Burner Tube

Primary Air

Inlet Holes

Figure 46 - Injector Holder On Outlet Burner Tube - Rear Burner

Injector

Holder

Primary Air

Inlet Holes

Figure 47 - Injector Holder On Outlet Burner Tube - Front Burner

Ports/Slots

Pilot

AssemblyPilot Air

Inlet Hole

Pilot

Assembly

Figure 48 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 15 through 17, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

For..com

108114

Image 24
Contents International OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Optional Remote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeMinimum Noncombustible Material Clearances See Between 8Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Remote-Ready Models OnlyConnecting to GAS Supply External Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Installing Log #2 Model CGX3930NT ShownInstalling Log #3 Model VGX30NT Shown Installing Log #3 Model LGX3924NT Shown Models LGX3924NT and LGX3924PTAttaching Grate to Base Assembly Operating HeaterAdding Lava Rock Lighting InstructionsTo Turn OFF GAS to Appliance Shutting Off HeaterShutting Off Burners Only pilot stays lit Manual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingThermostat Control Operation Flame Optional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrcta Series OperationInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillarySpecifications Wiring DiagramService Hints Technical ServiceIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListTHERMOSTAT-CONTROLLED VGX24NT, VGX24PT VGX30NT, VGX30PT29 THERMOSTAT-CONTROLLED Parts Available not ShownCGX3924NR, CGX3924PR REMOTE-READY LGX3924NT, LGX3924PT KEY Part Number LGX3924NT LGX3924PT Description QTY Replacement Parts AccessoriesOwners Registration Form International For . .com Not a UPC

INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER specifications

The Desa International Unvented (Vent-Free) Gas Log Heater stands as a remarkable solution for those seeking an efficient and aesthetically pleasing heating option for their homes. Recognized for its innovative design and advanced technology, this heater offers numerous benefits that cater to both functionality and style.

One of the main features of the Desa gas log heater is its vent-free design. This characteristic eliminates the need for ductwork or exhaust systems, allowing for easy installation in various locations, including living rooms, bedrooms, or recreational areas. With no external venting required, homeowners can enjoy increased flexibility in placement while saving on installation costs and labor. Moreover, the heater can fit seamlessly into existing fireplaces, creating a cozy ambiance without the need for traditional firewood.

Another standout feature of the Desa vent-free gas log heater is its exceptional energy efficiency. Utilizing infrared technology, the heater converts a high percentage of gas to heat, warming spaces quickly and reducing energy consumption. The unit is designed to operate with natural gas or propane, offering versatility depending on the homeowner's fuel preferences.

Safety is a top priority in the design of the Desa gas log heater. Equipped with an automatic shut-off system and an oxygen depletion sensor, the heater ensures secure operation by shutting down in case oxygen levels drop too low. This added safety feature provides peace of mind for families, allowing for safe use even during extended periods of operation.

Aesthetically, the Desa International gas log heater does not compromise on style. With an array of realistic log designs and finishes, homeowners can choose a heater that complements their interior decor perfectly. The unit’s flame effects mimic traditional wood-burning fires, enhancing the warm ambiance of any room.

In conclusion, the Desa International Unvented (Vent-Free) Gas Log Heater offers a unique combination of efficiency, safety, and aesthetics. Its vent-free design allows for flexible installation, while infrared heating technology ensures quick warmth and energy savings. Coupled with enhanced safety features and an attractive appearance, this gas log heater provides a practical and stylish heating solution for any home.