Desa GWP30T, GWP20T, GWN20T, WMN20, GN30T, GP30T, GWN30T Installation Items, Locating Heater

Page 8

INSTALLATION

Continued

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

for propane/LP gas, external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

sediment trap

tee joint

pipe wrench

for natural gas, test gauge connection*

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional CSA design- certified equipment shutoff valve can be purchased from your dealer. See Accessories, page 30.

LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall.

You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Pur- chase the floor mounting stand from your dealer. See Accessories, page 30.

WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content in the air.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving vehicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspec- tion, and service

in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 30. If planning to use fan, locate heater near an electrical outlet.

CEILING

 

6"

36"

Minimum

Minimum

From

 

Sides Of

 

Heater

 

 

Right

 

Side

Left

 

Side

 

 

Minimum To

 

Top Surface

 

Of Carpeting,

 

2" Tile Or Other

FLOOR

Combustible

Material

Figure 4 - Mounting Clearances As

Viewed From Front of Heater

8

www.desatech.com

107884-01H

Image 8
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Features Local CodesProduct Identification UnpackingAIR for Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Items Locating HeaterInstalling Heater to Wall Placing Heater On Mounting Bracket 20,000 Btu/Hr ModelsAttaching To Wall Anchor Method Installing Bottom Mounting Screws Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor with Optional Floor KIT Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersPropane/LP Checking GAS ConnectionsNatural Gas Pressure Testing Heater Gas Connections Open equipment shutoff valve see ,Lighting Instructions Manual Control Models For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure To Turn OFF GAS To ApplianceShutting Off Heater Shutting Off Burner Only pilot stays litThermostat Control Operation Burner Flame Pattern Inpecting HeaterPilot Flame Pattern Cleaning Maintenance ODS/PILOT and BurnerBurner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyReplace burner orifice See Cleaning and Mainte Gas leak. See Warning Statement aboveGP30, GP30T SpecificationsGN30, GN30T WMN20, GWN20 Service Hints Technical ServiceService Publications Replacement Parts Parts Under WarrantyIllustrated Parts Breakdown Parts List NJF 8CGWN20T, GWP20T GWN30T, GWP30T Parts List Accessories Equipment Shutoff Valve GA5010FAN Kits GA3250T Base KIT GA4550Parts Centrals Limited Warranty VENT-FREE Residential GAS Heaters Warranty InformationKeep this Warranty

GP30, GWN20T, GWN30T, GWN20, GWP20 specifications

Desa GWP20, GWP30T, GP30T, GN30T, and GP30 are advanced water heater models that stand out in the market for their efficiency, innovative technology, and user-friendly features. Each model is designed to cater to different consumer needs, offering reliable hot water solutions for residential and commercial applications.

The Desa GWP20 is a compact and efficient water heater that operates on a 20-gallon tank. Ideal for smaller households, it boasts fast heating capabilities and a durable construction that ensures longevity. Its user-friendly control panel allows for easy temperature adjustments, and its energy-saving mode helps reduce utility costs.

Moving up in capacity, the GWP30T features a 30-gallon tank, making it suitable for medium-sized households. This model incorporates a high-efficiency burner that maximizes heat output while minimizing gas consumption. With an upgraded insulation system, the GWP30T retains heat for longer periods, enhancing energy efficiency. The built-in diagnostics monitor performance, ensuring consistent operation and alerting users to any potential issues.

The GP30T is another 30-gallon model that emphasizes flexible installation options. It can be configured for various venting systems, making it adaptable for different home layouts. Its robust safety features, such as an automatic shut-off system, provide peace of mind for users. Additionally, the GP30T is equipped with a flame sensor for improved safety during operation.

For those seeking an efficient gas-powered unit, the GN30T delivers exceptional performance with a 30-gallon capacity. This model is designed to withstand the demands of larger households, featuring rapid recovery rates to provide a continuous supply of hot water. It utilizes advanced combustion technology that ensures efficient gas usage, striking the perfect balance between performance and energy costs.

Finally, the GP30 is a versatile water heater designed to meet diverse consumer needs. With a focus on sustainability, this model incorporates eco-friendly materials and technologies. The GP30 is packed with features that enhance its usability, such as customizable temperature settings, easy-to-read indicators, and a straightforward installation process.

In summary, Desa's GWP20, GWP30T, GP30T, GN30T, and GP30 water heaters are engineered for efficiency and reliability. Each model offers unique features tailored to specific user needs, from compact designs for smaller spaces to powerful systems for larger families. With an emphasis on modern technology and safety, Desa continues to be a leader in the water heating market.