Desa GP30T Installation, Ventilation AIR, Check GAS Type, Ventilation Air From Inside Building

Page 7

AIR FOR COMBUSTION

AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent open- ings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-con- trolled power vent. Heated air entering the attic will activate the power vent.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater.

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

Follow all local codes.

CHECK GAS TYPE

Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

12"

Figure 2 - Ventilation Air from Inside

Building

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

107884-01H

www.desatech.com

7

Image 7
Contents What to do if YOU Smell GAS Table of Contents Safety Information Unpacking Product FeaturesLocal Codes Product IdentificationConfined and Unconfined Space AIR for Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building InstallationVentilation AIR Check GAS TypeLocating Heater Installation ItemsInstalling Heater to Wall Attaching To Wall Anchor Method 20,000 Btu/Hr ModelsPlacing Heater On Mounting Bracket Mounting Base Feet to Heater Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Mounting Heater to Floor with Optional Floor KITTypical Inlet Pipe Diameters Connecting to GAS SupplyNatural Gas Checking GAS ConnectionsPropane/LP Open equipment shutoff valve see , Pressure Testing Heater Gas ConnectionsOperating Heater Manual Control Models For Your Safety Read Before LightingLighting Instructions Shutting Off Burner Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterThermostat Control Operation Pilot Flame Pattern Inpecting HeaterBurner Flame Pattern Cabinet Cleaning MaintenanceODS/PILOT and Burner Burner Pilot AIR InletObserved Problem Possible Cause Remedy TroubleshootingReplace burner orifice See Cleaning and Mainte Statement above Gas leak. See WarningGN30, GN30T WMN20, GWN20 SpecificationsGP30, GP30T Parts Under Warranty Service HintsTechnical Service Service Publications Replacement PartsIllustrated Parts Breakdown NJF 8C Parts ListGWN20T, GWP20T GWN30T, GWP30T Parts List Base KIT GA4550 AccessoriesEquipment Shutoff Valve GA5010 FAN Kits GA3250TParts Centrals Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Residential GAS Heaters

GP30, GWN20T, GWN30T, GWN20, GWP20 specifications

Desa GWP20, GWP30T, GP30T, GN30T, and GP30 are advanced water heater models that stand out in the market for their efficiency, innovative technology, and user-friendly features. Each model is designed to cater to different consumer needs, offering reliable hot water solutions for residential and commercial applications.

The Desa GWP20 is a compact and efficient water heater that operates on a 20-gallon tank. Ideal for smaller households, it boasts fast heating capabilities and a durable construction that ensures longevity. Its user-friendly control panel allows for easy temperature adjustments, and its energy-saving mode helps reduce utility costs.

Moving up in capacity, the GWP30T features a 30-gallon tank, making it suitable for medium-sized households. This model incorporates a high-efficiency burner that maximizes heat output while minimizing gas consumption. With an upgraded insulation system, the GWP30T retains heat for longer periods, enhancing energy efficiency. The built-in diagnostics monitor performance, ensuring consistent operation and alerting users to any potential issues.

The GP30T is another 30-gallon model that emphasizes flexible installation options. It can be configured for various venting systems, making it adaptable for different home layouts. Its robust safety features, such as an automatic shut-off system, provide peace of mind for users. Additionally, the GP30T is equipped with a flame sensor for improved safety during operation.

For those seeking an efficient gas-powered unit, the GN30T delivers exceptional performance with a 30-gallon capacity. This model is designed to withstand the demands of larger households, featuring rapid recovery rates to provide a continuous supply of hot water. It utilizes advanced combustion technology that ensures efficient gas usage, striking the perfect balance between performance and energy costs.

Finally, the GP30 is a versatile water heater designed to meet diverse consumer needs. With a focus on sustainability, this model incorporates eco-friendly materials and technologies. The GP30 is packed with features that enhance its usability, such as customizable temperature settings, easy-to-read indicators, and a straightforward installation process.

In summary, Desa's GWP20, GWP30T, GP30T, GN30T, and GP30 water heaters are engineered for efficiency and reliability. Each model offers unique features tailored to specific user needs, from compact designs for smaller spaces to powerful systems for larger families. With an emphasis on modern technology and safety, Desa continues to be a leader in the water heating market.