Figure 15 - Checking Gas Joints for

INSTALLATION

Continued

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 13).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP sup- ply to equipment shutoff valve for propane/LP (see Figure 14 or 15). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

 

Open

 

Shutoff Valve

 

 

Propane/LP

Equipment Shutoff Valve

Supply Tank

 

Control Valve Location

Figure 15 - Checking Gas Joints for

Propane/LP Gas

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open equipment shutoff valve (see Figure 13).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 14 or 15). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appli- ance, page 17 or 18).

OPERATING HEATER

FOR YOUR SAFETY

READ BEFORE LIGHTING

Closed

 

Figure 13 - Equipment Shutoff Valve

WARNING: If you do not fol-

Equipment Shutoff Valve

low these instructions exactly,

a fire or explosion may result

 

causing property damage, per-

 

sonal injury or loss of life.

Gas Meter

A. This appliance has a pilot which must be

 

lighted by hand. When lighting the pilot,

 

follow these instructions exactly.

 

B. BEFORE LIGHTING smell all around the

 

appliance area for gas. Be sure to smell next

Control Valve

to the floor because some gas is heavier than

air and will settle on the floor.

Location

 

Figure 14 - Checking Gas Joints for

Natural Gas

14

www.desatech.com

111826-04A

Image 14
Contents WHAT TO DO IF YOU SMELL GAS TABLE OF CONTENTS SAFETY INFORMATION Continued SAFETY INFORMATIONPRODUCT IDENTIFICATION Figure 1 - Product IdentificationLOCAL CODES PRODUCT FEATURESSAFETY PILOT UNPACKINGDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION AIR FOR COMBUSTION AND VENTILATIONContinued Confined and Unconfined SpaceVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From Outdoorsin a bedroom or bathroom INSTALLATIONWARNING Never install the heater in a recreational vehicleIf Using Mantel INSTALLATIONIf Not Using Mantel ContinuedContinued INSTALLATIONSafe Installation Materialraise the mantel to an accept- able height INSTALLATIONoperate the logs only with the flue damper open remove the mantelINSTALLATION CONNECTING TO GAS SUPPLYCHECKING GAS CONNECTIONS INSTALLATIONPRESSURE TESTING GAS SUPPLY PIPING SYSTEM Natural GasOPERATING HEATER INSTALLATIONPRESSURE TESTING HEATER GAS CONNECTIONS ContinuedREMOTE LIGHTING INSTRUCTIONS OPERATING HEATERContinued Setting The Time Shut-offProcedureSetting The Display C/24h and F /12h Battery Replacement5.Make sure ON/OFF switch is in -ON position Set Timer1.STOP! Read the safety information on page 2.STOP! Read safety information on pageOPERATING HEATER see Troubleshooting, pagesee Troubleshooting, page INSPECTING BURNERSCLEANING AND MAINTENANCE POSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYContinued TROUBLESHOOTINGsee Cleaning and Mainte Burner backfiring during comTROUBLESHOOTING WARNING If you smell gas Shut off gas supplyIDENTIFYING ERROR SIGNALS FROM RECIEVER TROUBLESHOOTINGWIRING DIAGRAM OBSERVED PROBLEMREPLACEMENT PARTS SERVICE HINTSTECHNICAL SERVICE PARTS UNDER WARRANTYVF-18N-PJD SPECIFICATIONSACCESSORIES VF-24N-PJDILLUSTRATED PARTS BREAKDOWN MODELS VF-18N-PJDAND VF-18P-PJDPARTS LIST ILLUSTRATED PARTS BREAKDOWN MODELS VF-24N-PJDAND VF-24P-PJDPARTS LIST Chassis111826-04A 111826-04A LIMITED WARRANTY VENT-FREEGAS LOG HEATERS WARRANTY INFORMATIONKEEP THIS WARRANTY