TROUBLESHOOTING
Continued
IDENTIFYING ERROR SIGNALS FROM RECIEVER |
| |
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY |
|
|
|
Longsignals(0.8secondtone,0.2 | Battery nearly down. (When | Replace battery |
second break) during ignition | signal appears the first time ap- |
|
| proximately 10 ignitions left) |
|
5 second continuous tone | Cable is not connected, ON/OFF | Connect cables |
| switch is in OFF position |
|
5 short signals (8.2 second tone, | Ignition not successful, possible | Swit to ON. Repeat procedure |
0.2 second break) | air in supplyline |
|
WIRING DIAGRAM
MAN Knob
Motor Knob
Combination Control
| Thermocurrent | ON/OFF Switch (Optional) | |
| Interrupter Block | ||
|
|
| |
|
|
| OFF |
|
|
| ON |
|
| 8 Wire Connecting Cable | |
|
| Thermocurrent Cable #2 | |
|
| or ON/OFF Switch | |
|
| Soldered Cable | |
|
|
| Thermocurrent Cable #1 |
Thermocouple | Ignition Cable | Antenna |
|
| SPARK | Receiver | SW TC |
Battery Compartment
SPARK | SW TC |
ON/OFF
Switch
Thermocurrent
Interrupter Block
Pilot
4 AA Batteries
MA GR MO SW
PANEL
www.desatech.com | 23 |