Desa VF-24N-PJD, VF-18P-PJD Operating Heater, Inspecting Burners, Continued, Shutting Off Heater

Page 18
11.Turn MAN-Knob to ON position - main gas flows.

OPERATING HEATER

Continued

10.Continue holding down metal core for about 10 seconds and then release the metal core. Pilot should stay lit. If not, repeat steps one through 4, page 17.

11.Turn MAN-Knob to ON position - main gas flows.

12.Turn Motor-knob to adjust flame. Knob has a slipping clutch that allows manual flame height adjustment.

TO TURN GAS OFF

TO APPLIANCE

Shutting Off Heater

Press OFF button on remote control to switch off main gas and pilot gas or manually turn

Motor-Knob clockwise Motor-Knob clockwise  to the "O" OFF position. to the "O" OFF position.

Shutting Off Burner Only (pilot stays lit)

Press to decrease the flame height and shut off main burner.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appli- ance, above or page 17)

see Troubleshooting, page 20

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Thermocouple

Thermocouple Shutting Off Burner Only (pilot stays lit)

Figure 20 - Incorrect Pilot Flame Pattern(Natural Gas Pilot Shown)

BURNER FLAME PATTERN Figure 21 shows correct burner flame pattern.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by heater, causing brief patches of orange flame.

If burner flame pattern is incorrect, as shown in Figure 22

turn appliance off (see To Turn Off Gas to Ap- pliance in column 1 or page 17

see Troubleshooting, page 20

Figure 21 - Correct Burner Flame Pattern

Yellow Tipping

at Top of Blue INSPECTING BURNERS

Flame

Figure 22 - Correct Burner Flame Pattern
Figure 19 - Correct Pilot Flame Pattern

(Natural Gas Pilot Shown)

18

www.desatech.com

111826-04A

Image 18
Contents WHAT TO DO IF YOU SMELL GAS TABLE OF CONTENTS SAFETY INFORMATION Continued SAFETY INFORMATIONPRODUCT IDENTIFICATION Figure 1 - Product IdentificationLOCAL CODES PRODUCT FEATURESSAFETY PILOT UNPACKINGDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION AIR FOR COMBUSTION AND VENTILATIONContinued Confined and Unconfined SpaceVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From Outdoorsin a bedroom or bathroom INSTALLATIONWARNING Never install the heater in a recreational vehicleIf Using Mantel INSTALLATIONIf Not Using Mantel ContinuedContinued INSTALLATIONSafe Installation Materialraise the mantel to an accept- able height INSTALLATIONoperate the logs only with the flue damper open remove the mantelINSTALLATION CONNECTING TO GAS SUPPLYCHECKING GAS CONNECTIONS INSTALLATIONPRESSURE TESTING GAS SUPPLY PIPING SYSTEM Natural GasOPERATING HEATER INSTALLATIONPRESSURE TESTING HEATER GAS CONNECTIONS ContinuedOPERATING HEATER ContinuedREMOTE LIGHTING INSTRUCTIONS Setting The Time Shut-offProcedureSetting The Display C/24h and F /12h Battery Replacement5.Make sure ON/OFF switch is in -ON position Set Timer1.STOP! Read the safety information on page 2.STOP! Read safety information on pageOPERATING HEATER see Troubleshooting, pagesee Troubleshooting, page INSPECTING BURNERSCLEANING AND MAINTENANCE POSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYContinued TROUBLESHOOTINGsee Cleaning and Mainte Burner backfiring during comTROUBLESHOOTING WARNING If you smell gas Shut off gas supplyIDENTIFYING ERROR SIGNALS FROM RECIEVER TROUBLESHOOTINGWIRING DIAGRAM OBSERVED PROBLEMREPLACEMENT PARTS SERVICE HINTSTECHNICAL SERVICE PARTS UNDER WARRANTYVF-18N-PJD SPECIFICATIONSACCESSORIES VF-24N-PJDILLUSTRATED PARTS BREAKDOWN MODELS VF-18N-PJDAND VF-18P-PJDPARTS LIST ILLUSTRATED PARTS BREAKDOWN MODELS VF-24N-PJDAND VF-24P-PJDPARTS LIST Chassis111826-04A 111826-04A WARRANTY INFORMATION KEEP THIS WARRANTYLIMITED WARRANTY VENT-FREEGAS LOG HEATERS