Desa FVFM27NR installation manual Installing Logs, Installing Bottom Log #1

Page 13

OWNER’S MANUAL

INSTALLATION

Bottom Log (#1)

Continued

INSTALLING LOGS

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re-

Burner

Port

Grate

Chassis Burner

Figure 16 - Installing Bottom Log (#1)

Top Log (#2)

Peg

Figure 18 - Installing Top Log (#2)

position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place bottom log (#1) on grate to fit as illustrated in Figure 16. Make sure open areas of log set line up with burner ports (see Figure 17). Log will fit securely on chassis. IMPORTANT: Make sure log does not cover any burner ports.

2.Facing front of unit, place top log (#2) onto the pegs in the center of the bot- tom log (see Figure 18).

3.Position log piece (#3) by aligning holes on underside with remaining pegs on bottom log (see Figure 19).

4.Place lava rock on fireplace floor around base of heater.

Burner

Log Piece (#3)

Logs

Ports

 

 

Peg

Figure 17 - Installing Log set (Top View)

Figure 19 - Installing Log Piece (#3)

105223

13

Image 13
Contents FVFM27NR Millivolt Remote Control Ready ModelWhat to do if YOU Smell GAS Patent PendingSafety Information Remote Control Accessories Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsCheck GAS Type InstallationMinimum Wall and Ceiling Clearances see Figure Log Size Side Wall CeilingIf Not Using Mantel If Using MantelMinimum Noncombustible Material Clearances Eration,Mantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesAttaching Flexible Gas Hose to Heater Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Bottom Log #1 Installing LogsOperating Heater For Your Safety Read Before LightingInstructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerObserved Problem Possible Cause TroubleshootingMaintenance, Observed Problem Possible Cause RemedyGas leak. See Warning statement at top TopSpecifications Cleaning and MaintenanceService Hints Technical ServiceReplacement Parts AccessoriesWiring Diagram FVFM27NR Illustrated Parts BreakdownDescription QTY Parts ListLimited Warranty VENT-FREE Natural GAS LOG Heaters Warranty Information

FVFM27NR specifications

Desa FVFM27NR is a modern and innovative product that embodies cutting-edge technology and design aesthetics, making it a standout choice in its category. This versatile device is tailored to meet the demands of consumers who seek both efficiency and performance in their daily activities.

One of the key features of the FVFM27NR is its robust build quality, which ensures durability and longevity. Constructed using high-grade materials, the device is designed to withstand regular use while maintaining a sleek appearance. This attention to detail not only enhances its functionality but also contributes to an appealing visual presence.

The FVFM27NR is equipped with advanced technologies that elevate its performance. With a powerful engine, the device delivers superior results across various applications. The incorporation of smart technology allows users to control and customize settings according to their specific needs, providing an intuitive user experience. Ergonomic design elements further enhance usability, ensuring that the device is comfortable to handle even during extended use.

Energy efficiency is another hallmark of the FVFM27NR. It integrates eco-friendly technologies that minimize power consumption without sacrificing performance. The energy-efficient operation not only reduces utility costs for users but also contributes positively to environmental sustainability.

Along with its efficiency and power, the FVFM27NR features a range of specialized modes that cater to different tasks. This versatility makes it suitable for various environments, whether in a home, office, or outdoor setting. The ability to switch between modes with ease allows for quick adaptation, making it a practical tool for users with diverse requirements.

Additionally, the FVFM27NR is designed with user safety in mind. It incorporates multiple safety features, including automatic shut-off and thermal protection, ensuring peace of mind during operation.

In conclusion, Desa FVFM27NR stands out as a leading option in its market segment, thanks to its combination of robust design, advanced technology, energy efficiency, versatility, and user safety. Whether for professional or personal use, it delivers exceptional value, making it an ideal investment for anyone seeking a reliable and effective device. With its modern features and characteristics, the FVFM27NR is well-positioned to meet contemporary lifestyle needs while ensuring optimal performance and satisfaction.