CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

CLEANING BURNER

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 28). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see page 20) or call DESA International’s Technical Service Depart- ment at 1-800-323-5190.

WhencallingDESAInternational,haveready:

your name

your address

• model and serial numbers of your heater

INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper

Ports/Slots

Primary Air

Injector Holder

• how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 27).

3.Blow air through the ports/slots and holes in the burner.

Inlet Hole

Burner

Tube

Figure 27 - Injector Holder On Outlet Burner Tube

Pilot Air

Inlet Hole

Pilot Assembly

Figure 28 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see page 20) or call DESA International’s Parts Department at 1-800- 972-7879 for referral information.

WhencallingDESAInternational,haveready:

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

When Gas Quality Is Bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

For more information, visit www.desatech.com

16

107099

Image 16
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual15,000 to 30,000 Btu/Hr With Thermostat Safety Information Local CodesAssembly Product FeaturesProduct Identification UnpackingAttaching Brass Front Trim to Front Panel Assembling and Attaching Brass TrimAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installation ItemsLocating Heater Check GAS TypeThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Installing Bottom Mounting Screws Mounting Heater on Optional Hearth BaseAttaching Mounting Bracket To Wall Placing Heater On Mounting BracketMounting Heater to Optional Hearth Base Securing Hearth Base to FloorSee Instructions Included With Mantel Kit Assembling Mantel Connecting to GAS Supply Gas ConnectionPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Close equipment shutoff valve see Fig- ureFor Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Inspecting BurnerThermostat Control Operation Pilot Flame PatternReplacement Parts Cleaning and MaintenanceService Hints Troubleshooting Line. Have gas line checked by local Natural gas companyGas odor even when control knob is in OFF Lation requirementsTechnical Service SpecificationsParts Centrals Accessories Illustrated Parts Breakdown RFN30TAParts List KEY RFN30TA Description QTYWarranty Information