Desa RFN30TA Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 14

VENT-FREE NATURAL GAS HEATER

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column 1. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position. Press in control knob for five (5) seconds (see Figure 21).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 17 through 19. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 15.

Ignitor Button

Control Knob

 

LO

 

PILOT

 

OFF

 

HI

IGNITOR

 

Figure 21 - Control Knob In The OFF Position

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 22 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise Clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

For more information, visit www.desatech.com

14

107099

Image 14
Contents 15,000 to 30,000 Btu/Hr With Thermostat OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Local CodesProduct Identification AssemblyProduct Features UnpackingAttaching Brass Front Trim to Front Panel Assembling and Attaching Brass TrimUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Heater InstallationInstallation Items Check GAS TypeMounting Heater to Wall Installation OptionsThermostat Sensing Bulb Attaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Placing Heater On Mounting BracketSee Instructions Included With Mantel Kit Assembling Mantel Securing Hearth Base to FloorMounting Heater to Optional Hearth Base Connecting to GAS Supply Gas ConnectionChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Close equipment shutoff valve see Fig- ureLighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureInspecting Burner Pilot Flame PatternService Hints Cleaning and MaintenanceReplacement Parts Troubleshooting Line. Have gas line checked by local Natural gas companyGas odor even when control knob is in OFF Lation requirementsParts Centrals SpecificationsTechnical Service Accessories Illustrated Parts Breakdown RFN30TAParts List KEY RFN30TA Description QTYWarranty Information