Desa VP30BTA Checking GAS Connections, Typical Inlet Pipe Diameters, Natural Gas, Propane/LP

Page 12

INSTALLATION

Continued

CAUTION:Useonlynew,black

IMPORTANT: Hold the pressure regulator with wrench when connecting it to gas piping and/or fittings. Do not over tighten pipe connection to regulator. The regulator body could be damaged.

ironorsteelpipe.Internally-tinned copper tubing may be used in cer- tainareas.Checkyourlocalcodes. Usepipeoflargeenoughdiameter to allow proper gas volume to

Pressure Regulator

3/8" NPT Pipe Nipple

Note: Burner bracket not shown for clarity

Heater

Cabinet

heater. If pipe is too small, undue loss of volume will occur.

Typical Inlet Pipe Diameters

20,000 Btu/hr models - 3/8" or greater

30,000 Btu/hr models - 1/2" or greater

Installation must include equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 15).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Install sediment trap in supply line as shown in Figure 15. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

 

External

Propane/LP

Regulator

Supply Tank

 

 

Vent

 

Pointing

 

Down

Figure 14 - External Regulator With Vent

Pointing Down

Connection*

Tee Joint

Ground Joint

 

 

Union

 

 

 

Reducer

Equipment

 

Bushing

 

Shutoff

 

to 1/8"

Gauge

Valve *

1/8" NPT

 

 

NPT

 

Test

Plug Tap

3" Min.

 

Trap

Tee

Natural Gas

Joint

From Gas Meter

Sediment

Cap

(4" W.C. to 10.5"

From External

 

Pipe

W.C. Pressure)

 

Nipple

Propane/LP

 

 

 

 

Regulator

 

 

(11" W.C. to 14"

 

 

W.C. Pressure)

Figure 15 - Gas Connection

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 21.

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

12

www.desatech.com

113061-01F

Image 12
Contents What to do if YOU Smell GAS Models VN20BTA, VP20BTA VN30BTA and VP30BTATable of Contents Safety InformationSafety Information Safety Information Product FeaturesLocal Codes UnpackingAir For Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Installation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Installation ItemsLocating Heater Installing Heater to Wall Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching To Wall Anchor MethodPlacing Heater On Mounting Bracket Connecting to GAS Supply Mounting Base Feet to Floor Where Required by local codeMounting heater to floor Mounting Base Feet to HeaterChecking GAS Connections Typical Inlet Pipe DiametersNatural Gas Propane/LPPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Ignitor Button Control KnobOperating Heater Inspecting HeaterCleaning Maintenance ODS/PILOT and BurnerBurner Pilot Air Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Maintenance, Gas leak. See Warning Statement aboveSpecifications Service HintsTechnical Service Service Publications Replacement PartsIllustrated Parts Breakdown ModelsVN20BTA, VP20BTA, VN30BTA, VP30BTA Parts list NJF 8CWarranty Information Keep this Warranty

VN20BTA, VN30BTA, VP20BTA, VP30BTA specifications

Desa VN30BTA, VP20BTA, VP30BTA, and VN20BTA are four advanced models from Desa that cater to diverse heating needs, incorporating innovative technologies and features aimed at enhancing performance and user experience.

The VN30BTA is renowned for its robust output and efficient heating capabilities. It features high thermal efficiency, enabling homeowners to enjoy optimal heat without excessive energy consumption. This model is equipped with advanced safety mechanisms, including automatic shut-off systems, ensuring user safety and peace of mind. Additionally, it has a stylish design that fits well in various home aesthetics.

Moving to the VP20BTA, this model is specifically designed for versatility and is capable of heating medium to large spaces efficiently. The VP20BTA has a user-friendly control interface, allowing for easy adjustments to temperature settings. Its compact form factor makes it ideal for those who have limited space but still desire a powerful heating solution. Furthermore, it leverages smart thermostat technology to maintain consistent temperatures while optimizing energy consumption.

The VP30BTA offers the highest heating output among this line, making it suitable for larger homes and commercial applications. This model incorporates cutting-edge infrared technology, which promotes even heat distribution. It also features a durable construction that ensures longevity and stability during operation. The VP30BTA is praised for its low emissions and eco-friendly design, appealing to environmentally conscious consumers.

Lastly, the VN20BTA serves as an entry-level option that combines affordability with reliability. Despite being the most budget-friendly model, it still maintains high standards of safety and efficiency. The VN20BTA is easy to install and operate, making it an excellent choice for those new to heating solutions. Its lightweight design and portability provide flexibility in usage, allowing users to move the unit as needed.

All these models showcase Desa's commitment to innovation, safety, and efficiency, making them solid choices for any heating requirement. Their features, from advanced safety systems to eco-friendly designs, reflect a comprehensive approach to modern heating solutions that meet the demands of various consumers. Whether for residential or commercial use, Desa's VN30BTA, VP20BTA, VP30BTA, and VN20BTA models stand out as reliable and effective heating options.