Desa VN20BTA Installation, Ventilation AIR, Check GAS Type, Ventilation Air From Inside Building

Page 7

AIR FOR COMBUSTION

AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

Installation

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

12"

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

Figure 2 - Ventilation Air from Inside

Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

CHECK GAS TYPE

Use only the correct type of gas (natural or pro- pane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

113061-01Fwww.desatech.com

Image 7
Contents Models VN20BTA, VP20BTA VN30BTA and VP30BTA What to do if YOU Smell GASSafety Information Table of ContentsSafety Information Unpacking Safety InformationProduct Features Local CodesConfined and Unconfined Space Air For Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Check GAS TypeInstallation Items InstallationLocating Heater Thermostat Sensing Bulb Installing Heater to WallAttaching To Wall Anchor Method Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Mounting Base Feet to Heater Connecting to GAS SupplyMounting Base Feet to Floor Where Required by local code Mounting heater to floorPropane/LP Checking GAS ConnectionsTypical Inlet Pipe Diameters Natural GasTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Heater Gas ConnectionsIgnitor Button Control Knob For Your Safety Read Before LightingOperating Heater Lighting InstructionsInspecting Heater Operating HeaterCabinet Cleaning MaintenanceODS/PILOT and Burner Burner Pilot Air InletObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Maintenance, Statement above Gas leak. See WarningService Publications Replacement Parts SpecificationsService Hints Technical ServiceModels Illustrated Parts BreakdownVN20BTA, VP20BTA, VN30BTA, VP30BTA NJF 8C Parts listKeep this Warranty Warranty Information

VN20BTA, VN30BTA, VP20BTA, VP30BTA specifications

Desa VN30BTA, VP20BTA, VP30BTA, and VN20BTA are four advanced models from Desa that cater to diverse heating needs, incorporating innovative technologies and features aimed at enhancing performance and user experience.

The VN30BTA is renowned for its robust output and efficient heating capabilities. It features high thermal efficiency, enabling homeowners to enjoy optimal heat without excessive energy consumption. This model is equipped with advanced safety mechanisms, including automatic shut-off systems, ensuring user safety and peace of mind. Additionally, it has a stylish design that fits well in various home aesthetics.

Moving to the VP20BTA, this model is specifically designed for versatility and is capable of heating medium to large spaces efficiently. The VP20BTA has a user-friendly control interface, allowing for easy adjustments to temperature settings. Its compact form factor makes it ideal for those who have limited space but still desire a powerful heating solution. Furthermore, it leverages smart thermostat technology to maintain consistent temperatures while optimizing energy consumption.

The VP30BTA offers the highest heating output among this line, making it suitable for larger homes and commercial applications. This model incorporates cutting-edge infrared technology, which promotes even heat distribution. It also features a durable construction that ensures longevity and stability during operation. The VP30BTA is praised for its low emissions and eco-friendly design, appealing to environmentally conscious consumers.

Lastly, the VN20BTA serves as an entry-level option that combines affordability with reliability. Despite being the most budget-friendly model, it still maintains high standards of safety and efficiency. The VN20BTA is easy to install and operate, making it an excellent choice for those new to heating solutions. Its lightweight design and portability provide flexibility in usage, allowing users to move the unit as needed.

All these models showcase Desa's commitment to innovation, safety, and efficiency, making them solid choices for any heating requirement. Their features, from advanced safety systems to eco-friendly designs, reflect a comprehensive approach to modern heating solutions that meet the demands of various consumers. Whether for residential or commercial use, Desa's VN30BTA, VP20BTA, VP30BTA, and VN20BTA models stand out as reliable and effective heating options.