Desa VP20BTA, VP30BTA, VN30BTA, VN20BTA installation manual Troubleshooting

Page 18

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

ODS/pilot lights but flame

1. Control knob not fully

1.

Press in control knob fully

goes out when control knob is

 

pressed in

2.

After ODS/pilot lights, keep con-

released

2. Control knob not pressed in

 

3.

long enough

3.

trol knob pressed in 30 seconds

 

Safety interlock system has

Wait one minute for safety in-

 

 

been triggered

 

terlock system to reset. Repeat

 

4.

Equipment shutoff valve not

4.

ignition operation

 

Fully open equipment shutoff

 

5.

fully open

5.

valve

 

Thermocouple connection

Hand tighten until snug, then

 

6.

loose at control valve

6.

tighten 1/4 turn more

 

Pilot flame not touching

A) Contact local natural or

 

 

thermocouple, which allows

 

propane/LP gas company

 

 

thermocouple to cool, caus-

 

B) Clean ODS/pilot (see

 

 

ing pilot flame to go out. This

 

 

 

problem could be caused by

 

Cleaning and Maintenance,

 

 

one or both of the following:

 

page 16) or replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially clogged

 

 

 

 

7.

ODS/pilot

7.

Replace pilot assembly

 

Thermocouple damaged

 

8.

Control valve damaged

8.

Replace control valve

 

 

 

 

 

Burner does not light after ODS/

1. Burner orifice is clogged

1.

Clean burner (see Cleaning

pilot is lit

 

 

 

and Maintenance, page 16) or

 

2.

Inlet gas pressure is too low

2.

replace burner orifice

 

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

 

 

 

 

Delayed ignition of burner

1. Manifold pressure is too

1.

Contact local natural or pro-

 

2.

low

2.

pane/LP gas company

 

Burner orifice is clogged

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 16) or

 

 

 

 

replace burner orifice

 

 

 

 

 

Burner backfiring during

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

combustion

 

damaged

 

and Maintenance, page 16) or

 

2.

Burner damaged

2.

replace burner orifice

 

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

18

www.desatech.com

113061-01F

Image 18
Contents What to do if YOU Smell GAS Models VN20BTA, VP20BTA VN30BTA and VP30BTATable of Contents Safety InformationSafety Information Local Codes Safety InformationProduct Features UnpackingUnusually Tight Construction Air For Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Check GAS Type InstallationVentilation AIR Ventilation Air From Inside BuildingInstallation Installation ItemsLocating Heater Installing Heater to Wall Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching To Wall Anchor MethodPlacing Heater On Mounting Bracket Mounting heater to floor Connecting to GAS SupplyMounting Base Feet to Floor Where Required by local code Mounting Base Feet to HeaterNatural Gas Checking GAS ConnectionsTypical Inlet Pipe Diameters Propane/LPPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaLighting Instructions For Your Safety Read Before LightingOperating Heater Ignitor Button Control KnobOperating Heater Inspecting HeaterBurner Pilot Air Inlet Cleaning MaintenanceODS/PILOT and Burner CabinetTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Maintenance, Gas leak. See Warning Statement aboveTechnical Service SpecificationsService Hints Service Publications Replacement PartsIllustrated Parts Breakdown ModelsVN20BTA, VP20BTA, VN30BTA, VP30BTA Parts list NJF 8CWarranty Information Keep this Warranty

VN20BTA, VN30BTA, VP20BTA, VP30BTA specifications

Desa VN30BTA, VP20BTA, VP30BTA, and VN20BTA are four advanced models from Desa that cater to diverse heating needs, incorporating innovative technologies and features aimed at enhancing performance and user experience.

The VN30BTA is renowned for its robust output and efficient heating capabilities. It features high thermal efficiency, enabling homeowners to enjoy optimal heat without excessive energy consumption. This model is equipped with advanced safety mechanisms, including automatic shut-off systems, ensuring user safety and peace of mind. Additionally, it has a stylish design that fits well in various home aesthetics.

Moving to the VP20BTA, this model is specifically designed for versatility and is capable of heating medium to large spaces efficiently. The VP20BTA has a user-friendly control interface, allowing for easy adjustments to temperature settings. Its compact form factor makes it ideal for those who have limited space but still desire a powerful heating solution. Furthermore, it leverages smart thermostat technology to maintain consistent temperatures while optimizing energy consumption.

The VP30BTA offers the highest heating output among this line, making it suitable for larger homes and commercial applications. This model incorporates cutting-edge infrared technology, which promotes even heat distribution. It also features a durable construction that ensures longevity and stability during operation. The VP30BTA is praised for its low emissions and eco-friendly design, appealing to environmentally conscious consumers.

Lastly, the VN20BTA serves as an entry-level option that combines affordability with reliability. Despite being the most budget-friendly model, it still maintains high standards of safety and efficiency. The VN20BTA is easy to install and operate, making it an excellent choice for those new to heating solutions. Its lightweight design and portability provide flexibility in usage, allowing users to move the unit as needed.

All these models showcase Desa's commitment to innovation, safety, and efficiency, making them solid choices for any heating requirement. Their features, from advanced safety systems to eco-friendly designs, reflect a comprehensive approach to modern heating solutions that meet the demands of various consumers. Whether for residential or commercial use, Desa's VN30BTA, VP20BTA, VP30BTA, and VN20BTA models stand out as reliable and effective heating options.