Desa VP1600ITB, VP2200ITB Checking GAS Connections, Pressure Testing Gas Supply Piping System

Page 11

OWNER’S MANUAL

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure external regulator has been installed be- tween propane/LP supply and heater. See Connecting to Gas Supply on page 10.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 15).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 15).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 16). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 12 and 13). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 13).

8.Replace front panel.

Open

Equipment

Shutoff

Valve

Closed

Figure 15 - Equipment Shutoff Valve

Control Valve Location

Propane/LP

Supply Tank

Equipment

Shutoff

Valve

Figure 16 - Checking Gas Joints

104247

11

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualVENT-FREE PROPANE/LP GAS Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating HeaterThermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Typical Inlet Pipe Diameters Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat Operation Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS To ApplianceInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingVice person Gas leak. See Warning statement at Illustrated Parts Breakdown VP1600ITB Parts ListVP2200ITB Control Position Label Service Hints SpecificationsReplacement Parts Technical ServiceModel VP1600ITB GA4000B Model VP2200ITB GA4010B AccessoriesEquipment Shutoff Valve GA5010 Floor Mounting StandWarranty Information

VP1600ITB, VP2200ITB specifications

The Desa VP2200ITB and VP1600ITB are advanced portable heaters designed for efficient heating solutions in a variety of settings. Both models showcase innovative features and technologies that make them standout choices for residential and commercial use.

The VP2200ITB is a powerful unit designed to provide substantial heating output, making it suitable for larger spaces. With a robust heating capacity, it ensures rapid warmth in cold conditions. On the other hand, the VP1600ITB is a slightly smaller model, ideal for medium-sized rooms or personal areas. This makes both units versatile, catering to different space heating needs.

One of the most notable features of both models is their digital thermostat, which provides precise temperature control. Users can easily set their desired heating levels, ensuring optimal comfort and reducing energy wastage. The adjustable heat settings, ranging from low to high, allow consumers to tailor the heat intensity according to specific requirements.

Both the VP2200ITB and VP1600ITB incorporate advanced safety technologies. These include a tip-over switch that automatically shuts off the heater if it is knocked over, and an overheat protection feature that prevents the unit from reaching unsafe temperatures. These safety mechanisms make them suitable for use in homes with children or pets.

Energy efficiency is another significant characteristic of these heaters. They are designed to provide maximum heat output with minimal energy consumption, resulting in reduced electricity bills. The environmentally friendly design is complemented by quiet operation, making them perfect for use in bedrooms, offices, or any space where noise levels should be kept to a minimum.

The heaters also feature compact and portable designs, equipped with handle grips for easy transportation. This means they can be effortlessly relocated from one room to another, providing flexibility according to changing heating needs.

Additionally, their sleek aesthetics allow them to blend seamlessly into various decors, ensuring that functionality does not come at the expense of style. With a range of features and practical technologies, the Desa VP2200ITB and VP1600ITB models are ideal solutions for effective heating, delivering warmth, safety, and efficiency in one package.