INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING: Maintain the mini- mum clearances shown in Figure

4.If you can, provide greater clear- ances from floor, ceiling, and join- ing wall.

You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 23.

WARNING: Never install the heater

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 23. If plan- ning to use fan, locate heater near an electri- cal outlet.

CEILING

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

CHECK GAS TYPE

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture,

clothing, or other flammable

objects are less than 36 inches

from the front, top, or sides of

8" Minimum From Sides Of Heater

36" Minimum

Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

test gauge connection *

sediment trap

tee joint

pipe wrench

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an ac- ceptable alternative to test gauge connec- tion. Purchase the optional CSA/AGA de- sign-certified equipment shutoff valve from your dealer. See Accessories, page 23.

 

the heater

• as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving ve- hicle will not hit it

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

Left

Right

Side

Side

Minimum

3" To Top

FLOOR

Surface

Of carpeting, Tile or

 

 

Other Combustible

 

Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

Continued

104247

7

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualVENT-FREE PROPANE/LP GAS Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating HeaterThermostat Sensing Bulb Installing Heater to WallAttaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Typical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Heater For Your Safety Read Before LightingLighting Instructions Thermostat Operation Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS To ApplianceInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingVice person Gas leak. See Warning statement at Illustrated Parts Breakdown VP1600ITB Parts ListVP2200ITB Control Position Label Service Hints SpecificationsReplacement Parts Technical ServiceModel VP1600ITB GA4000B Model VP2200ITB GA4010B AccessoriesEquipment Shutoff Valve GA5010 Floor Mounting StandWarranty Information

VP1600ITB, VP2200ITB specifications

The Desa VP2200ITB and VP1600ITB are advanced portable heaters designed for efficient heating solutions in a variety of settings. Both models showcase innovative features and technologies that make them standout choices for residential and commercial use.

The VP2200ITB is a powerful unit designed to provide substantial heating output, making it suitable for larger spaces. With a robust heating capacity, it ensures rapid warmth in cold conditions. On the other hand, the VP1600ITB is a slightly smaller model, ideal for medium-sized rooms or personal areas. This makes both units versatile, catering to different space heating needs.

One of the most notable features of both models is their digital thermostat, which provides precise temperature control. Users can easily set their desired heating levels, ensuring optimal comfort and reducing energy wastage. The adjustable heat settings, ranging from low to high, allow consumers to tailor the heat intensity according to specific requirements.

Both the VP2200ITB and VP1600ITB incorporate advanced safety technologies. These include a tip-over switch that automatically shuts off the heater if it is knocked over, and an overheat protection feature that prevents the unit from reaching unsafe temperatures. These safety mechanisms make them suitable for use in homes with children or pets.

Energy efficiency is another significant characteristic of these heaters. They are designed to provide maximum heat output with minimal energy consumption, resulting in reduced electricity bills. The environmentally friendly design is complemented by quiet operation, making them perfect for use in bedrooms, offices, or any space where noise levels should be kept to a minimum.

The heaters also feature compact and portable designs, equipped with handle grips for easy transportation. This means they can be effortlessly relocated from one room to another, providing flexibility according to changing heating needs.

Additionally, their sleek aesthetics allow them to blend seamlessly into various decors, ensuring that functionality does not come at the expense of style. With a range of features and practical technologies, the Desa VP2200ITB and VP1600ITB models are ideal solutions for effective heating, delivering warmth, safety, and efficiency in one package.