Desa VP2200ITB, VP1600ITB installation manual VENT-FREE PROPANE/LP GAS Heater, Safety Information

Page 2

®

VENT-FREE PROPANE/LP GAS HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to pro- pane/LP gas. The odor helps you detect a propane/LP gas leak. However, the odor added to propane/LP gas can fade. Propane/LP gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use any accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will re- main hot for a time after shut- down. Allow surface to cool be- fore touching.

Carefully supervise young chil- dren when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.This heater shall not be installed in a bedroom or bathroom.

4.If you smell gas

Shut off gas supply

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

If you cannot reach your gas supplier, call the fire department

5.Always run heater with plaque control knob at the 1, 2, 3, or 4 locked posi- tions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.

6.This heater needs fresh, outside air ven- tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6.

7.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

8.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

9.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

10.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

11.Turn off and unplug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

12.Operating heater above elevations of 4,500 feet could cause pilot outage.

13.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

2

104247

Image 2
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information VENT-FREE PROPANE/LP GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Heater InstallationInstallation Items Check GAS TypeInstalling Heater to Wall Thermostat Sensing BulbPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Connecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Manual Lighting ProcedureTo Select Heating Level Thermostat OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyVice person Gas leak. See Warning statement at Illustrated Parts Breakdown Parts List VP1600ITBVP2200ITB Control Position Label Technical Service SpecificationsReplacement Parts Service HintsFloor Mounting Stand AccessoriesEquipment Shutoff Valve GA5010 Model VP1600ITB GA4000B Model VP2200ITB GA4010BWarranty Information

VP1600ITB, VP2200ITB specifications

The Desa VP2200ITB and VP1600ITB are advanced portable heaters designed for efficient heating solutions in a variety of settings. Both models showcase innovative features and technologies that make them standout choices for residential and commercial use.

The VP2200ITB is a powerful unit designed to provide substantial heating output, making it suitable for larger spaces. With a robust heating capacity, it ensures rapid warmth in cold conditions. On the other hand, the VP1600ITB is a slightly smaller model, ideal for medium-sized rooms or personal areas. This makes both units versatile, catering to different space heating needs.

One of the most notable features of both models is their digital thermostat, which provides precise temperature control. Users can easily set their desired heating levels, ensuring optimal comfort and reducing energy wastage. The adjustable heat settings, ranging from low to high, allow consumers to tailor the heat intensity according to specific requirements.

Both the VP2200ITB and VP1600ITB incorporate advanced safety technologies. These include a tip-over switch that automatically shuts off the heater if it is knocked over, and an overheat protection feature that prevents the unit from reaching unsafe temperatures. These safety mechanisms make them suitable for use in homes with children or pets.

Energy efficiency is another significant characteristic of these heaters. They are designed to provide maximum heat output with minimal energy consumption, resulting in reduced electricity bills. The environmentally friendly design is complemented by quiet operation, making them perfect for use in bedrooms, offices, or any space where noise levels should be kept to a minimum.

The heaters also feature compact and portable designs, equipped with handle grips for easy transportation. This means they can be effortlessly relocated from one room to another, providing flexibility according to changing heating needs.

Additionally, their sleek aesthetics allow them to blend seamlessly into various decors, ensuring that functionality does not come at the expense of style. With a range of features and practical technologies, the Desa VP2200ITB and VP1600ITB models are ideal solutions for effective heating, delivering warmth, safety, and efficiency in one package.