THERMOSTAT SENSING BULB

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Locating Thermostat Sensing Bulb

1.Remove front panel of heater (see Fig- ure 7).

2.Locate thermostat sensing bulb just under burner assembly.

IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is pro- vided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sens- ing bulb is pointing up.

Thermostat

Sensing Bulb

Clamp

Figure 5 - Attaching Thermostat Sensing Bulb

INSTALLING HEATER TO WALL

Mounting Bracket

Locate mounting bracket in heater carton. Remove mounting bracket from carton.

Figure 6 - Mounting Bracket

Removing Front Panel Of Heater

1.Remove two screws near bottom cor- ners of front panel.

2.Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".

3.Pull bottom of front panel forward, then down.

Figure 7 - Removing Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching To Wall Stud: This method pro- vides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching To Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain minimum clearances shown in Figure 8. If you can, provide greater clear- ances from floor and joining wall.

2.Mark screw locations on wall (see Fig- ure 8).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

13"

16"

Min.

 

AdjoiningWall

 

Only Insert Mounting

18 3/4"

 

 

Screws Through Last

 

 

Min.

 

 

Hole On Each End

 

 

 

 

 

Floor

 

 

 

 

Model VP2200ITB

 

 

 

9 1/4"

16"

 

 

 

Min.

 

 

 

AdjoiningWall

Only Insert Mounting

18 3/4"

Screws Through Last

Min.

 

 

Hole On Each End

 

 

 

 

Floor

Model VP1600ITB

Figure 8 - Mounting Bracket Clearances

8

104247

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information VENT-FREE PROPANE/LP GAS HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation ItemsLocating Heater Check GAS TypeInstalling Heater to Wall Thermostat Sensing BulbPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Connecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure To Select Heating LevelTo Turn OFF GAS To Appliance Thermostat OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyVice person Gas leak. See Warning statement at Illustrated Parts Breakdown Parts List VP1600ITBVP2200ITB Control Position Label Specifications Replacement PartsTechnical Service Service HintsAccessories Equipment Shutoff Valve GA5010Floor Mounting Stand Model VP1600ITB GA4000B Model VP2200ITB GA4010BWarranty Information

VP1600ITB, VP2200ITB specifications

The Desa VP2200ITB and VP1600ITB are advanced portable heaters designed for efficient heating solutions in a variety of settings. Both models showcase innovative features and technologies that make them standout choices for residential and commercial use.

The VP2200ITB is a powerful unit designed to provide substantial heating output, making it suitable for larger spaces. With a robust heating capacity, it ensures rapid warmth in cold conditions. On the other hand, the VP1600ITB is a slightly smaller model, ideal for medium-sized rooms or personal areas. This makes both units versatile, catering to different space heating needs.

One of the most notable features of both models is their digital thermostat, which provides precise temperature control. Users can easily set their desired heating levels, ensuring optimal comfort and reducing energy wastage. The adjustable heat settings, ranging from low to high, allow consumers to tailor the heat intensity according to specific requirements.

Both the VP2200ITB and VP1600ITB incorporate advanced safety technologies. These include a tip-over switch that automatically shuts off the heater if it is knocked over, and an overheat protection feature that prevents the unit from reaching unsafe temperatures. These safety mechanisms make them suitable for use in homes with children or pets.

Energy efficiency is another significant characteristic of these heaters. They are designed to provide maximum heat output with minimal energy consumption, resulting in reduced electricity bills. The environmentally friendly design is complemented by quiet operation, making them perfect for use in bedrooms, offices, or any space where noise levels should be kept to a minimum.

The heaters also feature compact and portable designs, equipped with handle grips for easy transportation. This means they can be effortlessly relocated from one room to another, providing flexibility according to changing heating needs.

Additionally, their sleek aesthetics allow them to blend seamlessly into various decors, ensuring that functionality does not come at the expense of style. With a range of features and practical technologies, the Desa VP2200ITB and VP1600ITB models are ideal solutions for effective heating, delivering warmth, safety, and efficiency in one package.