Desa VP30BT, VP20BT Cleaning Maintenance, ODS/PILOT and Burner, Burner Pilot AIR Inlet, Cabinet

Page 16

INSPECTING HEATER

Continued

Figure 23 shows a correct burner flame pattern. Fig- ure 24 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

If burner flame pattern is incorrect, as shown in Figure 24

turn heater off (see To Turn Off Gas To Appli- ance, page 15

see Troubleshooting, page 18

Blue

Flame

1/2 Glass

Height

Figure 23 - Correct Burner Flame Pattern

Yellow Tipping

1/2 Glass

Height

Figure 24 - Incorrect Burner Flame

Pattern

CLEANING AND

MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent clean- ing due to excessive lint from carpeting, bedding material, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

ODS/PILOT AND BURNER

Use a vacuum cleaner, pressurized air or small, soft bristled brush to clean.

BURNER PILOT AIR INLET

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you donʼt follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot for dust and dirt.

3.Blow air through the ports/slots and holes in the burner.

4.Never insert objects into the pilot tube.

Clean the pilot assembly also. A yellow tip on the pi- lot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet about two inches from where the pilot flame comes out of the pilot assembly (see Figure 25). With the unit off, lightly blow air through the air inlet. You may blow through a drink- ing straw if compressed air is not available.

Pilot Assembly

Pilot Air Inlet

Figure 25 - Pilot Inlet Air (Propane/LP Pilot Shown)

CABINET

Air Passageways Use a vacuum cleaner or pressurized air to clean.

Exterior Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

16

www.desatech.com

107886-01J

Image 16
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Product FeaturesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Items Locating HeaterInstalling Heater to Wall Thermostat Sensing BulbAttaching To Wall Anchor Method Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Connecting to GAS Supply Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor Mounting Base Feet to HeaterChecking GAS Connections VN30BT, VP30BT 1/2 or greaterPressure Testing Heater GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaOperating Heater For Your Safety Read Before LightingLighting Instructions Inspecting Heater Cleaning Maintenance ODS/PILOT and BurnerBurner Pilot AIR Inlet CabinetSpecifications Service HintsTechnical Service Service PublicationsTroubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Gas leak. See Warning Statement aboveReplacement Parts AccessoriesIllustrated Parts Breakdown Models VN20BT, VP20BT VN30BT, VP30BTParts List NJF 8CKeep this Warranty Warranty InformationLimited Warranty VENT-FREE Residential GAS Heaters