Desa VP20BT, VP30BT, VN30BT, VN20BT installation manual Replacement Parts, Accessories

Page 21

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Gas odor even when control knob

1.

Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement on page 21

 

(see Checking Gas Connec-

 

2.

Control valve defective

 

tions, page 12)

 

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

 

trol valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement on page 21

 

(see Checking Gas Connec-

 

 

 

 

tions, page 12)

 

 

 

 

 

Moisture/condensation noticed

1.

Not enough combustion/ven-

1.

Refer to Air for Combustion

on windows

 

tilation air

 

and Ventilation requirements

 

 

 

 

(page 5)

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Productsʼ Technical Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your heater

the replacement part number

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA Heating Products at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

EQUIPMENT SHUTOFF VALVE GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap.

FAN KITS - GA3250T

For all models. Provides better heat distribution. Makes heater more efficient. Complete installation and operating instructions included.

Thermostatically-controlled, blower turns itself on and off as required.

ELECTRONIC IGNITOR KIT - GA435 Not Shown

For all piezo ignitor models. Provides easier

lighting of the pilot.

107886-01J

www.desatech.com

21

Image 21
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Features Local CodesUnpacking Providing Adequate Ventilation AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR InstallationCheck GAS Type Ventilation Air From Inside BuildingLocating Heater Installation ItemsThermostat Sensing Bulb Installing Heater to WallInstalling Bottom Mounting Screws Attaching To Wall Anchor MethodPlacing Heater On Mounting Bracket Mounting Base Feet to Floor Where required by local code Connecting to GAS SupplyMounting Heater to Floor Mounting Base Feet to HeaterVN30BT, VP30BT 1/2 or greater Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Heater GAS ConnectionsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Inspecting Heater ODS/PILOT and Burner Cleaning MaintenanceBurner Pilot AIR Inlet CabinetService Hints SpecificationsTechnical Service Service PublicationsObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Statement above Gas leak. See WarningAccessories Replacement PartsModels VN20BT, VP20BT VN30BT, VP30BT Illustrated Parts BreakdownNJF 8C Parts ListWarranty Information Keep this WarrantyLimited Warranty VENT-FREE Residential GAS Heaters