Quadra-Fire GARNET-D-CSB, GARNET-MBK, GARNET-D-PMH, GARNET-D-MBK, GARNET-D-CWL Class a Metal Chimney

Page 19

3. Class A Metal Chimney

TERMINATION

CAP

TOP

ADAPTOR

FLASHING

EXISTING

METAL

CHIMNEY4 in. (102mm) FLEX PIPE

SYSTEM

RETRO

CONNECTOR

DIRECT

VENT

PIPE

Figure 5.20

Step 4.

Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3mm) diameter holes through the top adapter, and into the chimney top. Ensure that you are drilling into the metal on the chimney. Twist lock the high wind termination cap onto the top adapter (Figures 5.22 and 5.23).

Figure 5.22

CAUTION

Ensure that existing chimney is functionally sound and clean.

Have inspection done by qualified chimney sweep or professional installer BEFORE converting to direct vent appliance.

Step 1.

Remove existing chimney cap.

Step 2.

Measure the distance from the top of the chimney to the bottom of the ceiling support box, add 3 in. (76mm) to this measurement, and cut a section of 4 in. (101mm) flex pipe to that length (the flex should be fully extended).

Step 3.

Connect the end of the flex pipe section to the underside of the top adapter, using four sheet metal screws (Figure 5.21).

Top Adapter

Flex Pipe

Sheet Metal Screws

Figure 5.21

High Wind Termination

Cap

Sheet Metal Screws

Drill Four 1/8 in. (3mm) Diamater Holes

Figure 5.23

Step 5.

Pull the flex pipe down through the ceiling support box, until it protrudes approximately 3 in. (76mm). Connect the flex pipe to the retro connector, and attach with sheet metal screws.

Step 6.

Push the flex pipe back up into the ceiling support box, center the retro connector, and attach it to the support box with sheet metal screws.

Step 7.

The connection between the appliance and the retro connector may be completed with sections of direct vent pipe.

August 1, 2008

Quadra-Fire · Garnet-T · 7016-127F

Page 19

Image 19
Contents Hot glass will cause burns What to do if you smell gasDo not Discard this Manual Do DiscardnotManufactured Date Serial Number Model Name Test Lab & Report NoTable of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Getting Started Tools will apply to every installationTools and Supplies Needed Clearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Do not USE FIELD-FABRICATED Venting Vent InformationVenting Components Use of Elbows Measuring StandardsExceptions For Horizontal Installations How to Use the Vent Graph Venting GuidelinesStep Type B Rear Installations for Use with Rear Vent KitFire Risk. Explosion Risk. Combustion Fume Risk 203mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type B Existing Masonry ChimneyCap Retro Connector Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble Before YOU BeginTrim Ring Propane Natural GAS Gas InformationFuel Conversions Converting to LP GasMounting Screws Pressure Regulator Tower Diaphragm Valve Regulator ReplacementPressure Gas Pressures Gas ConnectionCheck for GAS Leaks Wire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringIgnition Module Leg Leveling System Appliance SetupFlue Restrictor Installation Remove Shipping MaterialsPositioning the Logs AccessoriesMineral Wool Blower Installation Glass ReplacementKIT Contents Snap Disc White Shutter Adjustment Ignition Module Access and Battery ReplacementIntake Damper Operation Before Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramSL-D Series Vent Components Vent Components DiagramHHT SL-P Vent Components ListTermination Caps & Kits Description GARNET-TService Parts List cont’d. GARNET-T Service Parts List cont’d. GARNET-T Accessories Date of Service Performed By Description of Service Service And Maintenance LogHomeowner’s Notes Homeowner’s Notes Warranty Policy Lifetime WarrantyContact Information Garnet-TDealer Telephone

GARNET-D-CSB, GARNET-D-CWL, GARNET-MBK, GARNET-D-MBK, GARNET-D-PMH specifications

Quadra-Fire has long been a notable name in the realm of hearth products, and their GARNET series exemplifies the brand's commitment to quality, innovation, and performance. The GARNET series includes models such as the GARNET-D-CWL, GARNET-MBK, GARNET-D-CSB, GARNET-D-PMH, and GARNET-D-MBK, each designed to meet diverse consumer needs while maintaining the distinctive Quadra-Fire qualities.

The GARNET-D-CWL model is renowned for its clean, contemporary aesthetic, making it suitable for modern living spaces. Its powerful heating capabilities stem from advanced combustion technology, which ensures efficient fuel usage while maximizing warmth. The integration of an adjustable air control system provides users with the ability to manage the burning rate, allowing for customized heating experiences.

The GARNET-MBK variant is designed specifically with versatility in mind, offering a multi-fuel option that accommodates wood, pellets, and biofuels. This flexibility ensures that users can adapt their heating method based on availability and preference. The model also includes a large viewing window, providing an unobstructed view of the mesmerizing flames, making it a captivating focal point in any room.

For those seeking traditional aesthetics with modern efficiency, the GARNET-D-CSB model combines classic design elements with cutting-edge technology. This model emphasizes enhanced heat distribution through its efficient heat exchanger system, ensuring that warmth is spread evenly throughout the space. It also features a low-emission combustion system that meets the strictest environmental guidelines.

The GARNET-D-PMH model stands out with its programmable thermostat feature, allowing homeowners to set desired temperatures for different times of the day. This smart technology not only ensures comfort but also contributes to energy savings by reducing unnecessary fuel consumption. The GARNET-D-PMH further enhances user convenience with its easy-to-use control panel.

Lastly, the GARNET-D-MBK model is geared towards those who value efficiency without compromising style. It boasts a robust build designed for durability, coupled with high-efficiency ratings that significantly lower heating costs. Its sleek finish complements any decor, making it an ideal choice for both contemporary and traditional settings.

Together, the GARNET series from Quadra-Fire represents a fusion of style, efficiency, and advanced technology. With various models designed to cater to different preferences and needs, Quadra-Fire continues to lead the market in creating exceptional hearth solutions that enhance both comfort and ambiance in homes.