Quadra-Fire GARNET-D-PMH, GARNET-MBK, GARNET-D-MBK, GARNET-D-CWL Valve Regulator Replacement

Page 26

2. Valve Regulator Replacement

WARNING

Fire Risk.

Explosion Risk.

Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed.

Remove upper and lower back shield. Loosen the set col- lars on the extension rods with the 3/32 in. Allen wrench. Remove the rods and adapter cap.

A Mounting Screws

B Pressure Regulator Tower

C Diaphragm

Figure 6.5 Turn control knob to the OFF position, ensure that gas supply to the valve has been turned off. Using a Torx TH20, or slotted screwdriver, remove the three pressure reg- ulator mounting screws (A), pressure regulator tower (B), and diaphragm (C).

with the kit. Tighten screws securely. (Reference torque = 25 in./lb.) Install the enclosed identifi cation label (F) to the valve body where it can be seen.

Fill out the conversion label and attach it to the valve cover.

WARNING

Fire Risk.

Explosion Risk.

Gas Leak Risk.

Rubber gasket must be seated properly on valve face.

Do no install a valve or regulator that has been dropped.

WARNING

Fire Risk.

Explosion Risk.

If the information in these instructions is not followed exactly, a fi re, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.

The qualified service agency is responsible for the proper installation of this conversion kit. The installation is not proper and complete until the operation of the converted appliance is checked as specifi ed in the manufacturer’s instructions supplied with the kit.

E Screws

D

Rubber Gasket

Identification Label F

Figure 6.6 Ensure that the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assembly to the valve using the new screws (E) supplied

Page 26

Quadra-Fire · Garnet-T · 7016-127F

August 1, 2008

Image 26
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Hot glass will cause burnsSerial Number Model Name Test Lab & Report No Manufactured DateTable of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Tools and Supplies Needed Tools will apply to every installationGetting Started Selecting Appliance Location Clearances4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Measuring Standards Vent InformationVenting Components Use of Elbows Do not USE FIELD-FABRICATED VentingHow to Use the Vent Graph Venting Guidelines Exceptions For Horizontal InstallationsType B Rear Installations for Use with Rear Vent Kit StepFire Risk. Explosion Risk. Combustion Fume Risk 203mm Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type BCap Retro Connector Before YOU Begin Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble Assembling Slim Line Trim Ring and Heat ShieldTrim Ring Converting to LP Gas Gas InformationFuel Conversions Propane Natural GASValve Regulator Replacement Mounting Screws Pressure Regulator Tower DiaphragmGas Pressures Gas Connection PressureCheck for GAS Leaks Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthIgnition Module Remove Shipping Materials Appliance SetupFlue Restrictor Installation Leg Leveling SystemMineral Wool AccessoriesPositioning the Logs KIT Contents Glass ReplacementBlower Installation Snap Disc White Intake Damper Operation Ignition Module Access and Battery ReplacementShutter Adjustment Controls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram SL-D Series Vent ComponentsVent Components List HHT SL-PTermination Caps & Kits GARNET-T DescriptionService Parts List cont’d. GARNET-T Service Parts List cont’d. GARNET-T Accessories Service And Maintenance Log Date of Service Performed By Description of ServiceHomeowner’s Notes Homeowner’s Notes Lifetime Warranty Warranty PolicyDealer Telephone Garnet-TContact Information

GARNET-D-CSB, GARNET-D-CWL, GARNET-MBK, GARNET-D-MBK, GARNET-D-PMH specifications

Quadra-Fire has long been a notable name in the realm of hearth products, and their GARNET series exemplifies the brand's commitment to quality, innovation, and performance. The GARNET series includes models such as the GARNET-D-CWL, GARNET-MBK, GARNET-D-CSB, GARNET-D-PMH, and GARNET-D-MBK, each designed to meet diverse consumer needs while maintaining the distinctive Quadra-Fire qualities.

The GARNET-D-CWL model is renowned for its clean, contemporary aesthetic, making it suitable for modern living spaces. Its powerful heating capabilities stem from advanced combustion technology, which ensures efficient fuel usage while maximizing warmth. The integration of an adjustable air control system provides users with the ability to manage the burning rate, allowing for customized heating experiences.

The GARNET-MBK variant is designed specifically with versatility in mind, offering a multi-fuel option that accommodates wood, pellets, and biofuels. This flexibility ensures that users can adapt their heating method based on availability and preference. The model also includes a large viewing window, providing an unobstructed view of the mesmerizing flames, making it a captivating focal point in any room.

For those seeking traditional aesthetics with modern efficiency, the GARNET-D-CSB model combines classic design elements with cutting-edge technology. This model emphasizes enhanced heat distribution through its efficient heat exchanger system, ensuring that warmth is spread evenly throughout the space. It also features a low-emission combustion system that meets the strictest environmental guidelines.

The GARNET-D-PMH model stands out with its programmable thermostat feature, allowing homeowners to set desired temperatures for different times of the day. This smart technology not only ensures comfort but also contributes to energy savings by reducing unnecessary fuel consumption. The GARNET-D-PMH further enhances user convenience with its easy-to-use control panel.

Lastly, the GARNET-D-MBK model is geared towards those who value efficiency without compromising style. It boasts a robust build designed for durability, coupled with high-efficiency ratings that significantly lower heating costs. Its sleek finish complements any decor, making it an ideal choice for both contemporary and traditional settings.

Together, the GARNET series from Quadra-Fire represents a fusion of style, efficiency, and advanced technology. With various models designed to cater to different preferences and needs, Quadra-Fire continues to lead the market in creating exceptional hearth solutions that enhance both comfort and ambiance in homes.