7Electrical Information

A. Recommendation for Wire

See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch.

NOTE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA

C221.1.

B. Connecting to the Appliance

WARNING

Wire 110v to electrical junction box.

Do NOT wire 110v to the valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt systems.

1.This appliance may be used with a wall switch, wall mounted thermostat and / or a remote control.

2.If using thermostat, use one compatible with a millivolt gas valve system.

3.Follow parameters for locating thermostat (see individ- ual thermostat instructions) to ensure proper operation of appliance.

4.Use low resistance thermostat wire for wiring from igni- tion system to the wall switch and thermostat.

5.Use the following chart for wire sizing.

Wire Size

Max. Length

16 gauge

65 feet

18 gauge

40 feet

20 gauge

25 feet

22 gauge

18 feet

8.Ensure the thermostat is mounted level for accurate readings.

9.The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air.

10.If the thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired temperature in your home.

Do not connect this appliance to a thermostat serving any other appliance.

Bedroom installation in Canada requires this appliance to be connected to a thermostat.

WARNING

Shock hazard.

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or remove the grounding prong from this plug.

C.Standing Pilot Ignition System Wiring

This appliance DOES NOT require 110 VAC supply for operation. A wiring diagram is shown in Figure 7.1 on the next page.

This appliance is equipped with a millivolt control valve.

6.Keep wire lengths as short as possible by removing any excess wire length.

7.Low voltage and 110 VAC voltage cannot be shared within the same wall box.

August 1, 2008

Quadra-Fire · Garnet-T · 7016-127F

Page 29

Image 29
Contents Do not Discard this Manual What to do if you smell gasDo Discardnot Hot glass will cause burnsManufactured Date Serial Number Model Name Test Lab & Report NoTable of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Tools and Supplies Needed Tools will apply to every installationGetting Started Clearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Venting Components Use of Elbows Vent InformationMeasuring Standards Do not USE FIELD-FABRICATED VentingExceptions For Horizontal Installations How to Use the Vent Graph Venting GuidelinesStep Type B Rear Installations for Use with Rear Vent KitFire Risk. Explosion Risk. Combustion Fume Risk 203mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type B Existing Masonry ChimneyCap Retro Connector Slim Line Wall Thimble Installing Slim Line Trim Ring and Heat ShieldBefore YOU Begin Assembling Slim Line Trim Ring and Heat ShieldTrim Ring Fuel Conversions Gas InformationConverting to LP Gas Propane Natural GASMounting Screws Pressure Regulator Tower Diaphragm Valve Regulator ReplacementPressure Gas Pressures Gas ConnectionCheck for GAS Leaks Connecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Wire Size Max. LengthIgnition Module Flue Restrictor Installation Appliance SetupRemove Shipping Materials Leg Leveling SystemMineral Wool AccessoriesPositioning the Logs KIT Contents Glass ReplacementBlower Installation Snap Disc White Intake Damper Operation Ignition Module Access and Battery ReplacementShutter Adjustment Controls Operating InstructionsBefore Lighting Appliance Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramSL-D Series Vent Components Vent Components DiagramHHT SL-P Vent Components ListTermination Caps & Kits Description GARNET-TService Parts List cont’d. GARNET-T Service Parts List cont’d. GARNET-T Accessories Date of Service Performed By Description of Service Service And Maintenance LogHomeowner’s Notes Homeowner’s Notes Warranty Policy Lifetime WarrantyDealer Telephone Garnet-TContact Information

GARNET-D-CSB, GARNET-D-CWL, GARNET-MBK, GARNET-D-MBK, GARNET-D-PMH specifications

Quadra-Fire has long been a notable name in the realm of hearth products, and their GARNET series exemplifies the brand's commitment to quality, innovation, and performance. The GARNET series includes models such as the GARNET-D-CWL, GARNET-MBK, GARNET-D-CSB, GARNET-D-PMH, and GARNET-D-MBK, each designed to meet diverse consumer needs while maintaining the distinctive Quadra-Fire qualities.

The GARNET-D-CWL model is renowned for its clean, contemporary aesthetic, making it suitable for modern living spaces. Its powerful heating capabilities stem from advanced combustion technology, which ensures efficient fuel usage while maximizing warmth. The integration of an adjustable air control system provides users with the ability to manage the burning rate, allowing for customized heating experiences.

The GARNET-MBK variant is designed specifically with versatility in mind, offering a multi-fuel option that accommodates wood, pellets, and biofuels. This flexibility ensures that users can adapt their heating method based on availability and preference. The model also includes a large viewing window, providing an unobstructed view of the mesmerizing flames, making it a captivating focal point in any room.

For those seeking traditional aesthetics with modern efficiency, the GARNET-D-CSB model combines classic design elements with cutting-edge technology. This model emphasizes enhanced heat distribution through its efficient heat exchanger system, ensuring that warmth is spread evenly throughout the space. It also features a low-emission combustion system that meets the strictest environmental guidelines.

The GARNET-D-PMH model stands out with its programmable thermostat feature, allowing homeowners to set desired temperatures for different times of the day. This smart technology not only ensures comfort but also contributes to energy savings by reducing unnecessary fuel consumption. The GARNET-D-PMH further enhances user convenience with its easy-to-use control panel.

Lastly, the GARNET-D-MBK model is geared towards those who value efficiency without compromising style. It boasts a robust build designed for durability, coupled with high-efficiency ratings that significantly lower heating costs. Its sleek finish complements any decor, making it an ideal choice for both contemporary and traditional settings.

Together, the GARNET series from Quadra-Fire represents a fusion of style, efficiency, and advanced technology. With various models designed to cater to different preferences and needs, Quadra-Fire continues to lead the market in creating exceptional hearth solutions that enhance both comfort and ambiance in homes.