Quadra-Fire GARNET-D-MBK, GARNET-MBK Maintaining and Servicing Your Appliance, After servicing

Page 42

11 Maintaining and Servicing Your Appliance

Although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an appliance check-up at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Ensure appliance is completely cooled.

After servicing:

Replace front and glass, if removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualifi ed technician recommended.

Check:

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Obstructions of termination cap.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fi ttings.

Clean:

Glass

Air passageways, grilles, control compartment

Burner, burner ports. USE CAUTION WHEN CLEANING/

HANDLING CERAMIC BURNER.

Risk of:

• Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may

ignite.

• Restricted air fl ow affects burner operation.

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation. Longer operation without cleaning glass may cause a permanent white lm on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white fi lm.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional

12 hours.

Refer to maintenance instructions.

Page 42

Quadra-Fire · Garnet-T · 7016-127F

August 1, 2008

Image 42
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Hot glass will cause burnsSerial Number Model Name Test Lab & Report No Manufactured DateTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Tools will apply to every installation Getting StartedTools and Supplies Needed Selecting Appliance Location Clearances4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Measuring Standards Vent InformationVenting Components Use of Elbows Do not USE FIELD-FABRICATED VentingHow to Use the Vent Graph Venting Guidelines Exceptions For Horizontal InstallationsType B Rear Installations for Use with Rear Vent Kit StepFire Risk. Explosion Risk. Combustion Fume Risk 203mm Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type BCap Retro Connector Before YOU Begin Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble Assembling Slim Line Trim Ring and Heat ShieldTrim Ring Converting to LP Gas Gas InformationFuel Conversions Propane Natural GASValve Regulator Replacement Mounting Screws Pressure Regulator Tower DiaphragmGas Pressures Gas Connection PressureCheck for GAS Leaks Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthIgnition Module Remove Shipping Materials Appliance SetupFlue Restrictor Installation Leg Leveling SystemAccessories Positioning the LogsMineral Wool Glass Replacement Blower InstallationKIT Contents Snap Disc White Ignition Module Access and Battery Replacement Shutter AdjustmentIntake Damper Operation Operating Instructions Before Lighting ApplianceControls For Your Safety Read Before Lighting Lighting ApplianceFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram SL-D Series Vent ComponentsVent Components List HHT SL-PTermination Caps & Kits GARNET-T DescriptionService Parts List cont’d. GARNET-T Service Parts List cont’d. GARNET-T Accessories Service And Maintenance Log Date of Service Performed By Description of ServiceHomeowner’s Notes Homeowner’s Notes Lifetime Warranty Warranty PolicyGarnet-T Contact InformationDealer Telephone

GARNET-D-CSB, GARNET-D-CWL, GARNET-MBK, GARNET-D-MBK, GARNET-D-PMH specifications

Quadra-Fire has long been a notable name in the realm of hearth products, and their GARNET series exemplifies the brand's commitment to quality, innovation, and performance. The GARNET series includes models such as the GARNET-D-CWL, GARNET-MBK, GARNET-D-CSB, GARNET-D-PMH, and GARNET-D-MBK, each designed to meet diverse consumer needs while maintaining the distinctive Quadra-Fire qualities.

The GARNET-D-CWL model is renowned for its clean, contemporary aesthetic, making it suitable for modern living spaces. Its powerful heating capabilities stem from advanced combustion technology, which ensures efficient fuel usage while maximizing warmth. The integration of an adjustable air control system provides users with the ability to manage the burning rate, allowing for customized heating experiences.

The GARNET-MBK variant is designed specifically with versatility in mind, offering a multi-fuel option that accommodates wood, pellets, and biofuels. This flexibility ensures that users can adapt their heating method based on availability and preference. The model also includes a large viewing window, providing an unobstructed view of the mesmerizing flames, making it a captivating focal point in any room.

For those seeking traditional aesthetics with modern efficiency, the GARNET-D-CSB model combines classic design elements with cutting-edge technology. This model emphasizes enhanced heat distribution through its efficient heat exchanger system, ensuring that warmth is spread evenly throughout the space. It also features a low-emission combustion system that meets the strictest environmental guidelines.

The GARNET-D-PMH model stands out with its programmable thermostat feature, allowing homeowners to set desired temperatures for different times of the day. This smart technology not only ensures comfort but also contributes to energy savings by reducing unnecessary fuel consumption. The GARNET-D-PMH further enhances user convenience with its easy-to-use control panel.

Lastly, the GARNET-D-MBK model is geared towards those who value efficiency without compromising style. It boasts a robust build designed for durability, coupled with high-efficiency ratings that significantly lower heating costs. Its sleek finish complements any decor, making it an ideal choice for both contemporary and traditional settings.

Together, the GARNET series from Quadra-Fire represents a fusion of style, efficiency, and advanced technology. With various models designed to cater to different preferences and needs, Quadra-Fire continues to lead the market in creating exceptional hearth solutions that enhance both comfort and ambiance in homes.