Quadra-Fire 32198A installation instructions Clearances, TOP Vent Installations

Page 8

R

Cape Cod Wood Stove

CLEARANCES

TOP VENT INSTALLATIONS

MINIMUM CLEARANCES TO COMBUSTIBLES (In inches and millimeters.)

FIGURES 1, 2 & 3

SINGLE WALL: Six inch (6") diameter single wall, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built chimney suitable for use with solid fuels, or a masonry chimney, and the following clearances:

A

B

C

D

E

F

G

H

I

16"(406)

16"(406)

31.5"(800)

22"(558)

16"(406)

21"(533)

55"(1397)

18"(457)

16"(406)

DOUBLE WALL & MOBILE. HOME: Six inch (6") diameter double wall air insulated connector pipe with listed factory-

built Class “A” chimney, or a masonry chimney, (Mobile Home must be equipped with a spark arrestor), and the following clearances: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double wall connector pipe. (Mobel Home must equipped with a spark arrestor), and teh following clearances:

A

B

C

D

E

F

G

H

I

12"(305)

12"(305)

27.5"(698)

18"(457)

12"(305)

17"(431)

55"(1397)

18"(457)

12”(305) /6"*(152)

IN AN ALCOVE: Six (6") inch diameter double wall air insulated connector pipe with listed factory-built Class “A” chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Additionally, maximum depth of alcove shall be no more than 38"(965mm), and a minimum of 55"(1397mm) high above stove top to a combustible. The following clearances apply:

A

B

C

D

E

F

G

H

I

14"(355)

14"(355)

27.5"(698)

18"(457)

N/A

N/A

55"(1397)

18"(457)

14"(355)

*With 52" high x 42" wide wall protection spaced 1" from combustible surface. .

WALL PROTECTOR SPECIFICATIONS: MUST BE A MINIMUM OF 24 GAUGE

SHEET METAL WITH A 1" (25MM) AIR SPACE BETWEEN SHEET METAL AND

COMBUSTIBLE WALL. SHEET METAL MAY THEN BE COVERED WITH BRICK

OR TILE.

A

B

C

E

 

F

 

F

D

E

FIGURE 1

FIGURE 2

H

G

I

FIGURE 3

Page 8

32198A February 15, 2002

Image 8 Contents
Cape Cod Woodstove Cape Cod Wood Stove Welcome Contents Listings Listings & Code AprovalsSafety Label Label Location Back of StoveSide View DimensionsFront View TOP Vent Installations ClearancesRear Vent Installations Minimum Clearances to CombustiblesFloor Protection USA Minimum Floor ProtectorAccessories By the regulatory authority having jurisdictionInstallation Chimney Height RequirementsFlue & Venting Systems Venting SystemMasonry Chimney Installation Installation Chimney Connector Masonry CHIMNEY,Connection to a Masonry Fireplace Connection to a Metal Prefabricated Chimney Connection to AN Interior Metal Prefabricated Chimney Connection to AN Exterior Metal Prefabricated Chimney Mobile Home Installation Reversible Flue Collar AssemblyFirebrick Placement Outside AIR KIT Installation Blower Installation & Operation Blower Operating InstructionsOperation PRE-USE CheckBurning PROCESS, Wood Selection and StorageAIR Controls Primary AIR SystemTable a Heat Output Settings Operating TipsBuilding a Fire BREAK-IN PeriodMaintenance ASH RemovalChimney Cleaning Creosote -- Formation and Need For RemovalChimney CLEANING, Glass Care & Replacement Door & Gasket Kaowool Insulating Baffle BlanketTROUBLE- Shooting Draft ProblemsTroubleshooting Checklist Trouble Shooting Flue DraftPlease Contact Your Dealer to Order Replacement Parts PartsWarranty Cape Cod Woodstove