Quadra-Fire 32198A installation instructions Assembly, Reversible Flue Collar, Firebrick Placement

Page 23

R

Cape Cod Wood Stove

ASSEMBLY

INSTALLATION

1Place the unit in a location near the final installation area and follow the procedures below:

2Open the stove and remove all the parts and articles packed inside. Inspect all the parts and cast iron body for shipping damage. Contact your dealer if any irregularities are noticed.

3Install floor protection if the heater is being placed on a combustible floor. Refer to the section on floor protectors for required materials and sizes on page 10.

4REMOVE ANY LABELS FROM GLASS.

5DO NOT TILT THE UNIT ON THE CAST IRON LEGS: Lift the unit upright and place it into position on the floor protector.

6Ensure that the kaowool insulation is positioned snugly against the rear of the unit, (see page 33, for kaowool blanket location). This eliminates any unburned gases from escaping prior to burning.

REVERSIBLE FLUE COLLAR

The Cape Cod flue collar is reversible for either a top or rear venting installation. The unit is shipped with the flue collar in the top vent position. For rear vent installations adjust the flue collar as follows:

1.Remove 6 Phillips head screws from the vent collar shield, remove shield and discard.

2.Remove bolts from each side of the flue transition (2 total). (Place your free hand in flue opening to locate and retrieve nuts attached to bolts.)

3.Turn vent. Replace bolts and nuts.

FIREBRICK PLACEMENT

Ensure that the firebricks are correctly positioned as referenced by diagram below, and that the firebox does not contain any broken brick prior to operating the unit.

1

2

6.00

54.50

3

4

6.00

2.00

6

7

8

 

 

 

 

 

 

 

4.50

Part Numbers

 

 

834-3870 Brick Set

9

9.00

832-0550 Individual Brick

2.50 10

4.50

9.00 8.25

11

12

3.75

4.50

l m

n

o

 

 

p

 

 

 

 

s

 

13

15

16

9.00

 

1.35

 

8.50

 

 

14

 

 

 

3.00

 

 

 

6.31

18

7.50

9.00

 

 

 

 

 

17

 

 

 

1.35

4.50

 

 

 

 

 

k

11

12

q

 

 

 

13

14

 

j

 

 

r

 

15

 

18

 

16

17

 

32198A February 15, 2002

Page 23

Image 23 Contents
Cape Cod Woodstove Cape Cod Wood Stove Welcome Contents Listings & Code Aprovals ListingsLabel Location Back of Stove Safety LabelSide View DimensionsFront View Clearances TOP Vent InstallationsMinimum Clearances to Combustibles Rear Vent InstallationsUSA Minimum Floor Protector Floor ProtectionBy the regulatory authority having jurisdiction AccessoriesChimney Height Requirements InstallationVenting System Flue & Venting SystemsMasonry Chimney Installation Installation Masonry CHIMNEY, Chimney ConnectorConnection to a Masonry Fireplace Connection to a Metal Prefabricated Chimney Connection to AN Interior Metal Prefabricated Chimney Connection to AN Exterior Metal Prefabricated Chimney Mobile Home Installation Reversible Flue Collar AssemblyFirebrick Placement Outside AIR KIT Installation Blower Operating Instructions Blower Installation & OperationPRE-USE Check OperationWood Selection and Storage Burning PROCESS,Primary AIR System AIR ControlsOperating Tips Table a Heat Output SettingsBREAK-IN Period Building a FireASH Removal MaintenanceCreosote -- Formation and Need For Removal Chimney CleaningChimney CLEANING, Glass Care & Replacement Kaowool Insulating Baffle Blanket Door & GasketTROUBLE- Shooting Draft ProblemsTroubleshooting Checklist Flue Draft Trouble ShootingParts Please Contact Your Dealer to Order Replacement PartsWarranty Cape Cod Woodstove