Quadra-Fire QVI-35FB-S owner manual Termination Locations, Vent Termination Minimum Clearances

Page 19

6 Termination Locations

A. Vent Termination Minimum Clearances

WARNING

Fire Risk.

Maintain vent clearance to combustibles as specified.

DO NOT pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause fire.

 

 

HORIZONTAL

 

 

OVERHANG

2 FT.

20 INCHES MIN.

VERTICAL

MIN.

 

 

WALL

 

LOWEST

 

 

 

DISCHARGE

 

 

OPENING

 

GAS DIRECT VENT

 

 

TERMINATION CAP

 

 

 

 

X

 

 

12

 

 

ROOF PITCH

 

 

IS X/ 12

 

H (MIN.) - MINIMUM HEIGHT FROM ROOF

 

TO LOWEST DISCHARGE OPENING

Roof Pitch

 

H (Min.) Ft.

Flat to 6/12...........................................................1.0*

Over 6/12 to 7/12.................................................1.25*

Over 7/12 to 8/12.................................................1.5*

Over 8/12 to 9/12.................................................2.0*

Over 9/12 to 10/12...............................................2.5

Over 10/12 to 11/12 .............................................3.25

Over 11/12 to 12/12 .............................................4.0

Over 12/12 to 14/12.............................................5.0

Over 14/12 to 16/12.............................................6.0

Over 16/12 to 18/12.............................................7.0

Over 18/12 to 20/12.............................................7.5

Over 20/12 to 21/12.............................................8.0

* 3 foot minimum in snow regions

Figure 6.1 Minimum Height From Roof To Lowest Discharge

Opening

 

 

A

B

6 in. (minimum) up to 20 in.

18 in. minimum

152 mm/508 mm

457 mm

20 in. and over

0 in. minimum

Gas, Wood or Fuel Oil

Termination Cap

B

A *

Gas

Termination

Cap **

*If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover.

**In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap.

Figure 6.2 Staggered Termination Caps

Quadra-FireQVI-35FB-S2178-900 Rev. B • 12/08

19

Image 19
Contents What to do if you smell gas Model QVI-35FB-SHOT Surfaces Homeowner Reference Information CongratulationsXxxxxxxx User Guide Table of ContentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Decorative Doors, Fronts and Surrounds Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceFinal inspection by Standing Pilot IgnitionWhat to do if YOU Smell GAS Issue Solutions Frequently Asked QuestionsAfter Appliance is Lit Maintenance and Service Firebox Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsStanding Pilot Flame Patterns Typical Appliance System Getting StartedTypical System-Vent Pipe Tools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components QVI-35FB-S Fireplace Size RequirementsMinimum Fireplace Opening Minimum Fireplace SizeClearances to Mantels or other Combustibles above Appliance Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsAIR Passage Slide Plate Handle #8 Screw Slide Plate Bracket Placing, Securing and Leveling the Appli- anceDamper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsStanding Pilot Ignition System Wiring ON/OFF SwitchFan Replacement Junction Box InstallationOptional Accessories Variable Speed Control Junction BOX Blkblk BLK Finishing Appliance Setup Log Set QVI35FB-S Shown Install the Log AssemblyLOG Number 3 SRV768-705 Position log #3 LOG Number 2 SRV768-704 Position log #2Quadra-Fire QVI-35FB-S 2178-900 Rev. B 12/08 Air Shutter Settings Air Shutter SettingSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingModel Dimensions Appliance Dimension DiagramReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsService Parts Log Set AssemblyPart number list on following Stocked Service Parts ListAt Depot QVI-35FB-S Contact Information

QVI-35FB-S specifications

The Quadra-Fire QVI-35FB-S is a state-of-the-art pellet stove designed to provide efficient heating while enhancing the aesthetic of any living space. With a sleek design and robust performance, this model stands out in the realm of home heating solutions.

One of the key features of the QVI-35FB-S is its impressive heating capacity. It can produce up to 35,000 BTUs, making it suitable for heating areas up to 1,600 square feet. This capability ensures that even larger spaces can be effectively warmed, providing consistent comfort during harsh winter months.

The stove’s clean-burning technology is another highlight. It utilizes a highly efficient combustion process, which not only maximizes heat output but also minimizes emissions. This environmentally conscious approach makes the QVI-35FB-S an excellent choice for eco-friendly homeowners who prioritize sustainability without sacrificing comfort.

The design of the QVI-35FB-S is both functional and stylish. It features a large viewing window framed by a sleek, contemporary design that allows for a full view of the flickering flames. This visual appeal is enhanced by the option of various finishes, allowing homeowners to choose a look that complements their interior décor.

Incorporating advanced features, the QVI-35FB-S includes an automated feed system and a programmable thermostat, providing users with greater control over their heating preferences. The automated feed ensures that the pellets are delivered consistently, maintaining a steady heat output. Meanwhile, the programmable thermostat allows for temperature adjustments throughout the day, promoting energy efficiency.

Safety is also a top priority in the design of the QVI-35FB-S. It comes equipped with a built-in safety shut-off system that activates in the event of overheating, providing peace of mind for users. Additionally, the stove includes a heat shield and other safety features to prevent accidents, making it a family-friendly option.

Installation is straightforward, thanks to the versatile venting options available with the QVI-35FB-S. Homeowners can choose direct vent installation, allowing for efficient exhalation of exhaust gases while drawing in fresh air from outside. This feature expands placement possibilities in various rooms.

Overall, the Quadra-Fire QVI-35FB-S combines modern design with superior performance and safety features, making it a compelling addition to any home heating system. Its blend of style, efficiency, and technology position it as a leader in the pellet stove market, meeting the diverse needs of today’s homeowners.