B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).

Clearance to combustible material under the insert is 1/4 inch (6 mm). Clearance to sides of fireplace opening to combustibles is 6 inches (152 mm). Clearance from top of fireplace opening (152 mm) to combustibles extending 1 inch is 6 inches. Clearance from top of fireplace opening for combustibles extending 1 inch to 12 inches max. is 12 inches.

Use leveling legs to raise insert minimum 1/4 inch (6 mm) above combustible material or outer wrap of factory built firebox.

Combustible facings must not extend behind the insert surround.

Note: All measurements in inches.

INLET AIR

12 in. MAX.

EXHAUST VENT PIPE

 

VENT PIPE

 

 

MANTEL

12 in. MIN.

MEASUREMENTS FROM

TOP EDGE OF UNIT

Figure 5.2 Clearances to Mantels or other Combustibles above Appliance

18

Quadra-FireQVI-35FB-S2178-900 Rev. B • 12/08

Image 18
Contents Model QVI-35FB-S What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationXxxxxxxx Table of Contents User GuideCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Decorative Doors, Fronts and SurroundsStanding Pilot Ignition Final inspection byWhat to do if YOU Smell GAS Frequently Asked Questions Issue SolutionsAfter Appliance is Lit Maintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxStanding Pilot Flame Patterns Getting Started Typical Appliance SystemTypical System-Vent Pipe Design and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Minimum Fireplace Size Fireplace Size RequirementsMinimum Fireplace Opening QVI-35FB-SMantel and Wall Projections Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appli- ance AIR Passage Slide Plate Handle #8 Screw Slide Plate BracketFactory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressure Gas InformationFuel Conversion Gas ConnectionON/OFF Switch Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationJunction Box Installation Fan ReplacementOptional Accessories Variable Speed Control Junction BOX Blkblk BLK Finishing Appliance Setup Install the Log Assembly Log Set QVI35FB-S ShownLOG Number 2 SRV768-704 Position log #2 LOG Number 3 SRV768-705 Position log #3Quadra-Fire QVI-35FB-S 2178-900 Rev. B 12/08 Air Shutter Setting Air Shutter SettingsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionAppliance Dimension Diagram Model DimensionsReference Materials Vent Kits Components Direct Vent Flex Liner KitsLog Set Assembly Service PartsPart number list on following Service Parts List StockedAt Depot QVI-35FB-S Contact Information

QVI-35FB-S specifications

The Quadra-Fire QVI-35FB-S is a state-of-the-art pellet stove designed to provide efficient heating while enhancing the aesthetic of any living space. With a sleek design and robust performance, this model stands out in the realm of home heating solutions.

One of the key features of the QVI-35FB-S is its impressive heating capacity. It can produce up to 35,000 BTUs, making it suitable for heating areas up to 1,600 square feet. This capability ensures that even larger spaces can be effectively warmed, providing consistent comfort during harsh winter months.

The stove’s clean-burning technology is another highlight. It utilizes a highly efficient combustion process, which not only maximizes heat output but also minimizes emissions. This environmentally conscious approach makes the QVI-35FB-S an excellent choice for eco-friendly homeowners who prioritize sustainability without sacrificing comfort.

The design of the QVI-35FB-S is both functional and stylish. It features a large viewing window framed by a sleek, contemporary design that allows for a full view of the flickering flames. This visual appeal is enhanced by the option of various finishes, allowing homeowners to choose a look that complements their interior décor.

Incorporating advanced features, the QVI-35FB-S includes an automated feed system and a programmable thermostat, providing users with greater control over their heating preferences. The automated feed ensures that the pellets are delivered consistently, maintaining a steady heat output. Meanwhile, the programmable thermostat allows for temperature adjustments throughout the day, promoting energy efficiency.

Safety is also a top priority in the design of the QVI-35FB-S. It comes equipped with a built-in safety shut-off system that activates in the event of overheating, providing peace of mind for users. Additionally, the stove includes a heat shield and other safety features to prevent accidents, making it a family-friendly option.

Installation is straightforward, thanks to the versatile venting options available with the QVI-35FB-S. Homeowners can choose direct vent installation, allowing for efficient exhalation of exhaust gases while drawing in fresh air from outside. This feature expands placement possibilities in various rooms.

Overall, the Quadra-Fire QVI-35FB-S combines modern design with superior performance and safety features, making it a compelling addition to any home heating system. Its blend of style, efficiency, and technology position it as a leader in the pellet stove market, meeting the diverse needs of today’s homeowners.