Quadra-Fire QVI-35FB-S Installing Vent Pipe and Appliance, Vent Limits, Venting Components

Page 21

8 Installing Vent Pipe and Appliance

A. Vent Limits

The abbreviations listed in this vent table key are used in the vent diagrams.

Description

Minimum Vertical Run Length 14 ft.

Maximum Vertical Run Length 50 ft.

Horizontal venting is NOT allowed.

Vertical terminations are measured to top of chimney.

This appliance is listed for use with LINK-DV systems and components only. It is permissible to extend venting above existing chimney (within specified maximum verti- cal limits) using SL-D series or Dura Vent GS series 4 in. x 6-5/8 in. gas direct-vent pipe. Connection is made us- ing SRVLINK-ADP. The vent must be terminated with the cap supplied with the LINK-series vent kit.

WARNING! Risk of Fire/Explosion/Asphyxiation! Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

Vent this appliance directly outside.

Use separate vent system for this appliance.

CAUTION! ALL vent specifications MUST be followed. This product is tested and listed to these specifications. Appliance performance will suffer if specifications are not followed.

B. Venting Components

CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

The vertical vent termination system installed on this model includes:

One 3-foot section stainless steel flexible pipe (included with insert).

Flexible vent pipe for exhaust air (included with vent kit).

One length of 3-inch flexible vent pipe for combustion air (included with vent kit).

One pipe-to-cap adaptor (included with vent kit).

One vertical termination cap (included with vent kit).

C. Connecting Vent Pipe

Reference instructions in the termination kit.

Install the 3-inch flexible vent pipe(s) down through the chimney.

Secure the exhaust flexible vent pipe to the 3 foot section stainless steel flexible vent pipe using the factory- installed 3-inch collar in the stainless steel section of pipe (see Figure 8.1).

Use 3 screws to attach either a 4 foot or 30 foot section of inlet air vent to the inlet collar on the collar slide plate (see Figure 8.1). NOTE: The collar slide plate may be removed from appliance to aid installation.

Note: To achieve optimum performance of insert, minimize or avoid bends in exhaust vent pipe.

TERMINATION

CAP

ADAPTOR

EXHAUST COLLAR

INLET AIR COLLAR

EXHAUST

VENT PIPE

V= 14 FT. MINIMUM 50 FT. MAXIMUM

3 INCH COLLAR

(Factory installed to

stainless steel section)

WARNING: DO NOT

BLOCK PIPE END WITH

INSULATION OR ANY OTHER

SEALING MATERIAL

STAINLESS STEEL

PIPE - 3 FT. MIN.

REQUIRED (INCLUDED)

INLET AIR

VENT PIPE

COLLAR ATTACHMENT

BRACKET

Figure 8.1

Quadra-FireQVI-35FB-S2178-900 Rev. B • 12/08

21

Image 21
Contents Model QVI-35FB-S What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationXxxxxxxx User Guide Table of ContentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyClear Space Decorative Doors, Fronts and SurroundsStanding Pilot Ignition Final inspection byWhat to do if YOU Smell GAS Frequently Asked Questions Issue SolutionsAfter Appliance is Lit Maintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianLogs FireboxStanding Pilot Flame Patterns Typical Appliance System Getting StartedTypical System-Vent Pipe Design and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size QVI-35FB-SClearances to Mantels or other Combustibles above Appliance Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsAIR Passage Slide Plate Handle #8 Screw Slide Plate Bracket Placing, Securing and Leveling the Appli- anceMasonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationGas Pressure Gas ConnectionStanding Pilot Ignition System Wiring Wiring RequirementsON/OFF Switch Electrical InformationJunction Box Installation Fan ReplacementOptional Accessories Variable Speed Control Junction BOX Blkblk BLK Finishing Appliance Setup Log Set QVI35FB-S Shown Install the Log AssemblyLOG Number 3 SRV768-705 Position log #3 LOG Number 2 SRV768-704 Position log #2Quadra-Fire QVI-35FB-S 2178-900 Rev. B 12/08 Air Shutter Settings Air Shutter SettingTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingAppliance Dimension Diagram Model DimensionsReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsPart number list on following Service Parts List StockedAt Depot QVI-35FB-S Contact Information

QVI-35FB-S specifications

The Quadra-Fire QVI-35FB-S is a state-of-the-art pellet stove designed to provide efficient heating while enhancing the aesthetic of any living space. With a sleek design and robust performance, this model stands out in the realm of home heating solutions.

One of the key features of the QVI-35FB-S is its impressive heating capacity. It can produce up to 35,000 BTUs, making it suitable for heating areas up to 1,600 square feet. This capability ensures that even larger spaces can be effectively warmed, providing consistent comfort during harsh winter months.

The stove’s clean-burning technology is another highlight. It utilizes a highly efficient combustion process, which not only maximizes heat output but also minimizes emissions. This environmentally conscious approach makes the QVI-35FB-S an excellent choice for eco-friendly homeowners who prioritize sustainability without sacrificing comfort.

The design of the QVI-35FB-S is both functional and stylish. It features a large viewing window framed by a sleek, contemporary design that allows for a full view of the flickering flames. This visual appeal is enhanced by the option of various finishes, allowing homeowners to choose a look that complements their interior décor.

Incorporating advanced features, the QVI-35FB-S includes an automated feed system and a programmable thermostat, providing users with greater control over their heating preferences. The automated feed ensures that the pellets are delivered consistently, maintaining a steady heat output. Meanwhile, the programmable thermostat allows for temperature adjustments throughout the day, promoting energy efficiency.

Safety is also a top priority in the design of the QVI-35FB-S. It comes equipped with a built-in safety shut-off system that activates in the event of overheating, providing peace of mind for users. Additionally, the stove includes a heat shield and other safety features to prevent accidents, making it a family-friendly option.

Installation is straightforward, thanks to the versatile venting options available with the QVI-35FB-S. Homeowners can choose direct vent installation, allowing for efficient exhalation of exhaust gases while drawing in fresh air from outside. This feature expands placement possibilities in various rooms.

Overall, the Quadra-Fire QVI-35FB-S combines modern design with superior performance and safety features, making it a compelling addition to any home heating system. Its blend of style, efficiency, and technology position it as a leader in the pellet stove market, meeting the diverse needs of today’s homeowners.