GE Monogram ZTD910, ZKD910 Installation Below Wall Ovens, Design Information, Warming Drawer

Models: ZKD910 ZTD910

1 8
Download 8 pages 49.27 Kb
Page 6
Image 6
Installation

Design Information

Warming Drawer

Installation

Below

Wall Ovens

INSTALLATION

BELOW A

SINGLE OVEN

2x2 or 2x4 Anti-Tip Block Against Rear Wall, 9" From Floor to Bottom of Block

23-1/2" Min.

Inside

Oven

Cutout

9"

9-1/4"

A

1" Min. Above Toekick or Adjust to Oven Installation Height

NOTE: Additional clearance between cutouts may be required. Check to be sure that oven supports above the Warming Drawer location does not obstruct the required interior 23-1/2” depth and 9-1/4” height.

2" Min.

 

Allow 5/8"

 

Overlap on

 

All Sides

23-1/4"

10-1/2"

B

INSTALLATION

BELOW A

DOUBLE OVEN

23-1/2" Min.

Inside

Oven

Cutout

2x2 or 2x4

 

Anti-Tip Block

 

Against Rear

 

Wall, 9" From

 

Floor to

9"

Bottom of

 

Block9-1/4"

A

1" Min. Above Toekick

Dim. A

Dim. B

ZTD910 28-1/2” 30”

ZKD910 25-1/2” 26-3/4”

 

 

NOTE: Additional clearance between

 

Allow 5/8"

cutouts may be required. Check to be

 

Overlap on

sure that oven supports above the

 

All Sides

Warming Drawer location does not

 

 

 

 

obstruct the required interior 23-1/2”

2" Min.

depth and 9-1/4” height.

 

 

 

23-1/4"

 

 

 

 

 

 

10-1/2"

 

 

B

When installed under a wall oven:

Warming drawers are approved for installation below only certain specified wall oven models. See the label attached to the top of the warming drawer for approved models.

When installed, the front face of the drawer will be nearly flush with adjacent cabinetry doors.

Drawer overlaps will conceal cut edges on all sides of the opening.

The rough opening for the drawer must be:

Depth: 23-1/2" min. from inside back to front of cabinet frame.

Width: 25-1/2" for 27" wide models, 28-1/2" for 30" wide models.

Height: 9-1/4".

Allow 2" min. between oven and drawer

cutouts for clearance of overlaps.

NOTE: If you are installing in frameless cabinets, it may be necessary to install 1/2” wide cleats to accept drawer mounting screws. See drawer for mounting screw locations.