10 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

Wire the appliance junction box to 110-120 VAC. This is required for use of optional accessories (standing pilot ignition).

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.

This appliance uses a standing pilot ignition system.

Open the control access panel.

A red or black ignitor button (as shown in Figure 10.1) indicates this appliance is standing pilot ignition.

IGNITOR BUTTON

Figure 10.1 Location of Ignitor Button

B. Standing Pilot Ignition System Wiring

The standing pilot ignition system wiring DOES NOT require a 110 VAC supply to operate.

A 110 VAC junction box MUST be installed for use with a fan or remote control. See Figure 10.3 for junction box wiring. Keep wire lengths short as possible.

NOTICE: DO NOT wire 110 VAC to the millivolt valve! This will damage the valve.

If using a thermostat use one compatible with a millivolt gas valve system:

-Install the thermostat in the location as indicated in the thermostat instructions to ensure proper operation of appliance.

-Use low resistance thermostat wire for wiring from ignition system to the wall switch and thermostat.

-Keep wire lengths short as possible by removing any excess wire length.

ON/OFF Switch

An ON/OFF switch is included with appliance and should attached to surround/facing. (See Installation instructions for remote control).

If desired an additional wall switch or thermostat may be added to system as shown in Figure 10.2).

STANDING

 

 

PILOT

 

 

 

 

 

REMOTE SWITCH

 

 

 

PIGTAIL

 

 

ON

 

 

 

OFF

 

 

VALVE

ON/OFF

 

 

SWITCH

 

 

 

 

 

WHT

 

 

 

RED

 

OPTIONAL WALL SWITCH,

 

 

 

THERMOSTAT OR REMOTE

Figure 10.2

Standing Pilot Ignition Wiring Diagram

 

 

 

Quadra-FireQVI-35FB-S2178-900 Rev. B • 12/08

25

Image 25
Contents What to do if you smell gas Model QVI-35FB-SHOT Surfaces Homeowner Reference Information CongratulationsXxxxxxxx User Guide Table of ContentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyClear Space Decorative Doors, Fronts and SurroundsFinal inspection by Standing Pilot IgnitionWhat to do if YOU Smell GAS Issue Solutions Frequently Asked QuestionsAfter Appliance is Lit Maintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianLogs FireboxStanding Pilot Flame Patterns Typical Appliance System Getting StartedTypical System-Vent Pipe Tools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size QVI-35FB-SClearances to Mantels or other Combustibles above Appliance Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsAIR Passage Slide Plate Handle #8 Screw Slide Plate Bracket Placing, Securing and Leveling the Appli- anceMasonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationGas Pressure Gas ConnectionStanding Pilot Ignition System Wiring Wiring RequirementsON/OFF Switch Electrical InformationFan Replacement Junction Box InstallationOptional Accessories Variable Speed Control Junction BOX Blkblk BLK Finishing Appliance Setup Log Set QVI35FB-S Shown Install the Log AssemblyLOG Number 3 SRV768-705 Position log #3 LOG Number 2 SRV768-704 Position log #2Quadra-Fire QVI-35FB-S 2178-900 Rev. B 12/08 Air Shutter Settings Air Shutter SettingSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingModel Dimensions Appliance Dimension DiagramReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsService Parts Log Set AssemblyPart number list on following Stocked Service Parts ListAt Depot QVI-35FB-S Contact Information

QVI-35FB-S specifications

The Quadra-Fire QVI-35FB-S is a state-of-the-art pellet stove designed to provide efficient heating while enhancing the aesthetic of any living space. With a sleek design and robust performance, this model stands out in the realm of home heating solutions.

One of the key features of the QVI-35FB-S is its impressive heating capacity. It can produce up to 35,000 BTUs, making it suitable for heating areas up to 1,600 square feet. This capability ensures that even larger spaces can be effectively warmed, providing consistent comfort during harsh winter months.

The stove’s clean-burning technology is another highlight. It utilizes a highly efficient combustion process, which not only maximizes heat output but also minimizes emissions. This environmentally conscious approach makes the QVI-35FB-S an excellent choice for eco-friendly homeowners who prioritize sustainability without sacrificing comfort.

The design of the QVI-35FB-S is both functional and stylish. It features a large viewing window framed by a sleek, contemporary design that allows for a full view of the flickering flames. This visual appeal is enhanced by the option of various finishes, allowing homeowners to choose a look that complements their interior décor.

Incorporating advanced features, the QVI-35FB-S includes an automated feed system and a programmable thermostat, providing users with greater control over their heating preferences. The automated feed ensures that the pellets are delivered consistently, maintaining a steady heat output. Meanwhile, the programmable thermostat allows for temperature adjustments throughout the day, promoting energy efficiency.

Safety is also a top priority in the design of the QVI-35FB-S. It comes equipped with a built-in safety shut-off system that activates in the event of overheating, providing peace of mind for users. Additionally, the stove includes a heat shield and other safety features to prevent accidents, making it a family-friendly option.

Installation is straightforward, thanks to the versatile venting options available with the QVI-35FB-S. Homeowners can choose direct vent installation, allowing for efficient exhalation of exhaust gases while drawing in fresh air from outside. This feature expands placement possibilities in various rooms.

Overall, the Quadra-Fire QVI-35FB-S combines modern design with superior performance and safety features, making it a compelling addition to any home heating system. Its blend of style, efficiency, and technology position it as a leader in the pellet stove market, meeting the diverse needs of today’s homeowners.