2.CODES

The water heater and burner must be installed in accordance with those installation regulations in force in the local area where the installation is to be made. Authorities having jurisdiction must be consulted before installation is made. In the absence of such requirements, the installation shall be in accordance with the instructions in this manual, the water heater Installation and Maintenance manual, appliance markings and supplemental instructions and in compliance with the Standard for Installation of Domestic Gas Conversion Burners and the latest edition of the National Fuel Gas Code, ANSI Z223.1. Where required by the Canadian authority having jurisdiction, the equipment must be installed in accordance with the latest edition of the Installation Code for Gas Burner Appliances and Equipment CAN/CSA B149.1 and/or B149.2 and applicable Provincial Regulations.

3.ELECTRICAL SPECIFICATIONS

SU-3 Electrical Specifications

Primary Electric Input

Secondary Electric Input

Total Watts

Total Amps

 

 

 

 

120 Volt, 60 Hz, 1 Ph

24 Volts

150 Max

3 or less

 

 

 

 

Electric Wiring

See appliance rating decal for electrical service requirements. The appliance must be electrically supplied and grounded in accordance with the requirements of the authority having jurisdiction or in the absence of such requirements, with the latest edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, the electrical service must conform to local electrical codes and/or CSA C22.1, Canadian Electrical Code, Part 1.

Connect multi-pin connector at end of flexible conduit from the water heater to the multi-pin plug on the burner control box.

To avoid serious damage, DO NOT energize the unit until the system and appliance is full of water.

The burner is grounded through the electrical connection to the water heater. Be certain the water heater has been properly grounded.

Refer to the burner control wiring diagram below and located inside the burner control cabinet for further information.

Blower Motor - 120 Volt/ 60 Hz/1 Phase, 1/6 HP PSC motor.

SU-3 Wiring Diagram

4

PV500-56 06/12

Image 4
Contents Installation & Maintenance Manual Table of Contents Safety Considerations For Your SafetyElectrical Specifications CodesCombustion and Ventilation AIR  All Air From OutdoorsVenting GAS Supply and PipingInlet Pressure NAT. GASGas Burner Piping Burner Operation Electrode and Flame Sensor PositioningBurner Setup and Adjustment SU3 Gas ManifoldCommissioning Checklist PV500-56 06/12 Maintenance Instructions Troubleshooting Condition SolutionsMaterials List PartPV500-56 06/12