Procom SSU320RHL-S, SSU320RHN-GB Illustrated Parts Breakdown, Part Number Description, Qty

Page 20

ILLUSTRATED

PARTS BREAKDOWN

SSU320RHN-GB SSU320RHL-GB

SSU320RHN-B SSU320RHL-B

SSU320RHN-G SSU320RHL-G

SSU320RHN-S SSU320RHL-S

Key No.

Part Number

Description

QTY

 

 

NG

LP

 

 

 

 

 

 

 

 

 

 

1

SLU35A410(NG)

BURNER

ASSEMBLY

1

 

 

 

 

 

 

 

2

SLU35A410(LP)

BURNER

ASSEMBLY

 

1

 

 

 

 

 

 

3

SLU35A420

BURNER

ASSEMBLY

1

1

 

 

 

 

 

 

4

ML091-05

INJECTOR

 

1

 

 

 

 

 

 

 

5

ML091-10

INJECTOR

 

 

1

 

 

 

 

 

6

ML056-04

CONNECTOR

1

1

 

 

 

 

 

7

SLU35A031

OUTLET TUBE

1

1

 

 

 

 

 

8

NAY03-05-01

IGNITOR CABLE

1

1

 

 

 

 

 

 

9

AL092-01

IGNITOR

 

1

1

 

 

 

 

 

 

10

QL027-02

INJECTOR

 

1

 

 

 

 

 

 

 

11

QL028-02

INJECTOR

 

 

1

 

 

 

 

 

 

12

ND4703X400-RH

ODS

 

1

 

 

 

 

 

 

 

13

ND4908X400-RH

ODS

 

 

1

 

 

 

 

 

 

14

MCL08-01

KNOB

 

1

1

 

 

 

 

 

15

SL035A032

ODS INLET TUBE

1

1

 

 

 

 

 

16

NV2020-22

GAS VALVE

1

1

 

 

 

 

 

17

SLU35A020

INLET TUBE ASSEMBLY

1

1

 

 

 

 

 

18

NRV82FB-4

REGULATOR

1

 

 

 

 

 

 

19

NRV82FB-9

REGULATOR

 

1

 

 

 

 

 

20

NAYB02-00

ELECTRONIC MODULE

1

1

 

 

 

 

 

21

NAYB01-00

REMOTE CONTROL

1

1

 

 

 

 

 

 

20

Image 20
Contents WATERVAPORABY-PRODUCTOFUNVENTED Room Heaters Installer Please leave these instructions with the consumerWhat to do if YOU Smell GAS Table of Contents Do not place Propane/LP supply tank Product Features Local CodesUnpacking Product IdentificationAIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater LocationProviding Adequate Ventilation Unusually Tight ConstructionVentilation Air From lnside Building Ventilation Air From OutdoorsInstallation Check GAS TypeMinimum Wall and Ceiling Clearances Connecting to GAS SupplyInstallation Items Needed Test Pressures Equal To or Less Than 1/2 PSIG3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 PSIG3.5kPa LOG Placement Place log 4 on log 1 and log 3, as shownRemotecontrol Operating Instruction For Your Safety Read Before LightingOperating Heater Operating FAN Manual Operating InstructionsProcedure match light Manual LightingCleaning and MAIN- Tenance Cabinet MainburnerAir Passageways ExteriorSpecifications Replacement PartsTroubleshooting Service person should serviceObserved Problem Possiblecause Remedy Before servicing. Only a qualifiedClean burner see Cleaning Observed Problem Possiblecause QTY Illustrated Parts BreakdownPart Number Description QTY