We recommend you keep the burner and pilot assembly clean and free of dust and dirt.

To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home

center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don't fol- low directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for

at least thirty minutes.

2 . Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (See Figure 23).

3 . B l o w a i r t h r o u g h t h e ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yel- low tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 24). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if com- pressed air is not available.

Figure 24 - Pilot Air Inlet Hole

MAINBURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

CABINET

Air Passageways

Use a vacuum cleaner or pressur- ized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

Logs

If you remove logs for cleaning, re- fer to Installing Logs to properly re- place logs.

Replace logs if broken or chipped (dime size or larger).

Figure 25 - Override Control System Diagram

Figure 23 - Burner Primary Air

Inlet

15

Image 15
Contents Installer Please leave these instructions with the consumer What to do if YOU Smell GASWATERVAPORABY-PRODUCTOFUNVENTED Room Heaters Table of Contents Do not place Propane/LP supply tank Product Identification Product FeaturesLocal Codes UnpackingUnusually Tight Construction AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationVentilation Air From Outdoors Ventilation Air From lnside BuildingCheck GAS Type InstallationConnecting to GAS Supply Installation Items NeededMinimum Wall and Ceiling Clearances Checking GAS Connections Test Pressures In Excess Of 1/2 PSIG3.5kPaTest Pressures Equal To or Less Than 1/2 PSIG3.5 kPa Place log 4 on log 1 and log 3, as shown LOG PlacementFor Your Safety Read Before Lighting Operating HeaterRemotecontrol Operating Instruction Manual Operating Instructions Operating FANManual Lighting Procedure match lightCleaning and MAIN- Tenance Exterior CabinetMainburner Air PassagewaysReplacement Parts SpecificationsBefore servicing. Only a qualified TroubleshootingService person should service Observed Problem Possiblecause RemedyClean burner see Cleaning Observed Problem Possiblecause Illustrated Parts Breakdown Part Number DescriptionQTY QTY