Procom MN060HPA, MN100TPA, MN100HPA NTO Turn OFFn, GAS to Appliance, Shutting Off Heater

Page 11

OPERATING YOUR HEATER

Manual Control Models

nLIGHTINGn

INSTRUCTIONS

1.STOP! Read the safety information on the side of

heater.

2.Check that gas supply to heater is on.

3.Push in gas control knob

slightly and turn clockwise to the OFF position (see Figures 15&16).

4.Wait five (5) minutes to clear out any air. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of the heater. If you do not smell gas, go to the next step.

5.Push in gas control knob slightly and turn counter-

clockwise to“PILOT/IGN” and depress for five(5) seconds

NOTE: The first time that the heater

is operated after

connecting

the gas supply , the

control knob

should be depressed for about thirty (30) seconds. This will allow air to

b l e e d

f r o m

t h e

g a s

system.

 

 

 

6.With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights.

7.Keep control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 5,6 and 7.

8.To select the desired heating level, partially press down the control knob slightly and rotate

counterclockwise . Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between locked positions.

nTO SELECTn

HEATING LEVEL

WARNING: When running heater,set control knob at ON, LOW, or HIGH locked positions(see Figures 18 & 19). Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Slightly press in control knob and turn counterclockwise to the ON, LOW or HIGH positions (see Figures 18 & 19).

Figure 15 - Control Knob In The OFF Position (MN060HPA)

Figure 16 - Control Knob In The OFF Position (MN100HPA)

Figure 17 - Pilot

MN060HPA

Figure 18 - Burner Patterns

Figure 19 - Burner Patterns

nTO TURN OFFn

GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise

to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (Pilot Stays Lit)

Turn control knob clockwise to the PILOT/IGN position.

nMANUAL LIGHTINGn

PROCEDURE

1.Remove lower front panel (see Figure 6 page 7)

2.Follow steps 1 through 5 under Lighting Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.Follow step 8 under Lighting Instructions.

5.Replace lower front panel.

1 1

Image 11
Contents MN060HPA MN100HPA MN100TPA OWNER’S Operation and Installation ManualSafety Information Product Features Determining if You Have Confined or Unconfined Space Fresh AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationIng the space of the adjoining AIR for Combustion VentilationVentilation AIR Locating Heater Installation Check GAS TypeInstallation Needs Ventilation AIRMethods For Attaching Mounting Bracket To Wall InstallationFastening Heater to Wall Mounting Bracket Removing Lower Front Panel Of HeaterPlacing Heater on Mounting Bracket Installing Bottom Mounting ScrewsTypical Inlet Pipe Diameters Connecting to GAS SupplyImportant Install Read Before Lighting NFOR Your SAFETYnOperating Your Heater Checking GAS Connections Shutting Off Heater MN060HPANTO Turn OFFn GAS to ApplianceRead Before Lighting Operating Your HeaterOperating Heater Cleaning MaintenanceInspecting Burner Observed Problem Possible Cause Remedy TroubleshootingPossible Cause Remedy Observed ProblemHeater produces unwanted odors Models MN060HPA,MN100HPA, MN100TPA SpecificationsParts Under Warranty MN060HPA MN100HPAMN060HPA Illustrated Parts BreakdownODS Parts List MN060HPAKEY Part NO. Number Description QTYMN100HPA NRV81FI-6 Parts List MN100HPAKEY Part Number Description QTY MN100TPA Part Description Number QTY Part List MN100TPA