OPERATING YOUR HEATER
THERMOSTAT MODEL
MN100TPA
nFOR YOUR SAFETYn
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
4.Wait five(5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of heater. If you don’t smell gas, go to the next step.
5.Turn control knob counterclock-
wise to the PILOT position.
WHAT TO DO IF YOU SMELL GAS | qualified | service | person | or gas |
|
|
|
|
|
| ||||||||||||||||
supplier for | repairs. |
|
|
|
|
|
|
|
|
| ||||||||||||||||
• | Do not try | to light any appliance. |
|
|
|
|
|
|
|
|
| |||||||||||||||
6. With | control |
| knob | pressed in, |
|
|
|
|
|
| ||||||||||||||||
• | Do | not | touch | any | electric | push | down | and | release | ignitor |
|
|
|
|
|
| ||||||||||
| switch, do | not use any phone |
|
|
|
|
|
| ||||||||||||||||||
| button. This | will | light | pilot. The |
|
|
|
|
|
| ||||||||||||||||
| in your building. |
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
| pilot is attached to the front of |
|
|
|
|
|
| |||||||||||||||
• | Immediately | call |
| your | gas | burner. If | needed, keep | press- | Figure 22 - Burner | Partterns | ||||||||||||||||
| supplier from a neighbor’s | ing | ignitor button until pilot lights. | |||||||||||||||||||||||
| nTHERMOSTAT CONTROL OPERATIONn | |||||||||||||||||||||||||
| phone . Follow the gas | Note: If | pilot | does not | stay | lit, refer | ||||||||||||||||||||
| supplier’s | instructions. |
|
| to Troubleshooting, pages 14 | The thermostatic control used on this | ||||||||||||||||||||
• | If you | cannot | reach | your gas | through 16. | Also | contact | a | quali- | model | differs | from | standard | |||||||||||||
| supplier, call the fire |
|
|
| fied | service person | or gas | sup- | thermostats. Standard | thermostats | ||||||||||||||||
|
|
|
| simply | turn on and off | the burner. The | ||||||||||||||||||||
| department. |
|
|
|
|
| plier | for | repairs. Until repairs are | thermostat used on this heater senses | ||||||||||||||||
C. | Use only | your hand to push in | m a de , | l ig ht |
| pi lot |
| w i t h | the room temperature. | At times the | ||||||||||||||||
or turn the gas control knob. |
| Never | match.To light | pilot | with match, | room may exceed the set temperature. | ||||||||||||||||||||
| see Manual Lighting Procedure. | If so,the burner will shut | off. The burner | |||||||||||||||||||||||
use tools. If the knob will |
| not push | ||||||||||||||||||||||||
| 7. Keep control knob pressed in for | will cycle back on when room tempera- | ||||||||||||||||||||||||
in or turn | by hand, don’t try to | repair | 30 seconds after lighting pilot.After | ture drops below the set temperature. | ||||||||||||||||||||||
it , call a qualified service technician | 30 seconds, release control knob. | The control knob can be set t o any | ||||||||||||||||||||||||
or gas supplier. Force or attempted | • | If | control | knob | does | not | comfort level between HI and LO. | |||||||||||||||||||
repair may result in a fire or explosion. | pop | up when | released, contact a | Note: The thermostat |
| sensing bulb | ||||||||||||||||||||
D. | Do not use | this | appliance if | qualified | service | person | or | gas | measures the temperature of air near | |||||||||||||||||
the heater cabinet.This may not always | ||||||||||||||||||||||||||
any part has been under water. | supplier for | repairs. |
|
|
| |||||||||||||||||||||
|
|
| agree with room temperature |
| ||||||||||||||||||||||
Immediately call a qualified service | Note: If pilot | goes | out,repeat steps 3 | (depending on housing | construction, | |||||||||||||||||||||
technician to inspect the appliance | through 7.This |
| heater has a safety | installation location, | room | size, | ||||||||||||||||||||
and to replace any part of | the control | interlock system. Wait one(1) | open | air temperatres,etc.) | Frequent | |||||||||||||||||||||
system and any gas control | which | minute before lighting pilot again. | use of your heater will let you deter- | |||||||||||||||||||||||
mine your own comfort levels. |
1. STOP! Read | the safety |
information on the side of heater.
2.Make sure equipment shutoff valve is fully open.
3.Turn control knob clockwise to the OFF position.
wise to desired seating level. The main burner should light. Set control knob to any heat level between HI and LO. (see Figure 22)
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
nTO TURN OFFn
GAS TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2.Turn off all electric power to the appliance if service is to be performed.
Shutting Off Burner Only (pilot |
|
stays lit ) |
|
Turn control knob clockwise | to |
the PILOT position. |
|
1 2