SYSTEM TROUBLE ERROR CODES

Trouble

System Trouble

Action

Indication

Condition

 

E-11-NN

Keypad Tamper

A keypad has been removed for the wall. Call installing company for service if problem cannot be

 

 

repaired.

E-12-NN

Expansion Zone

Call installing company for service.

 

Module Response

 

 

Failure

 

E-13-NN

Expansion Module

The cover has been removed from a zone expansion module. A problem has been detected with an

 

Tamper

Expansion Module. Call installing company for service.

 

 

 

E-14-NN

Relay Board Response

NN= Relay Board Number. Call installing company for service.

 

Failure

 

 

 

 

E-15-NN

RF Transmitter Tamper

Wireless Transmitter Tamper Cover removed. NN=Transmitter Number. Call installing company for

 

 

service.

 

 

 

E-16-NN

Wireless Receiver Jam

A problem has been detected with the wireless receiver. Call installing company for service.

 

 

 

E-17-NN

Receiver Tamper

Call installing company for service.

 

Condition

 

 

 

 

E-18-NN

KeyFob Transmitter

The batteries (2) in the wireless KeyFob transmitter indicated are low and should be replaced. The

 

Low Battery

replacement battery is the #386 watch battery.

 

 

Warning: Replace batteries only with the same type as specified above. Use of another battery may

 

 

present a risk of fire or explosion. Do not recharge or disassemble battery, or dispose of in fire.

29

Image 29
Contents Operating Guide for your GEM-K4 and GEM-K4RF Keypads Important Test Your System Weekly IntroductionTable of Contents Keypad Controls & Indicators TROUBLE, INSTANT, INTERIOR, CANCELLED, and Bypass Arming the System Arming AW AY Setting the Alarm When LeavingPriority Arming Selectively Bypassing ZonesArea Arming Optional Managers ModeInstant Protection Arming in Stay ModeArming Stay Protecting Yourself AT Home Stay Disarming the System Turning OFF the AL ARM Disarming When ReturningAlarm Indication / Silencing an Alarm Fire-Zone Trouble Fire ProtectionImportant! Read Carefully Preparing a Fire Escape PlanFamily Rehearsal Floorplan Limitations of Fire Alarm Warning System Function Menu P9600 and GEM-P3200 control panels only Function Menu Function Menu Relay Group Central Station Monitoring Communicator FeaturesSecurity Bypass/Unbypass Advanced FeaturesExit-Delay Restart Programming User Codes Entering the User Program ModeProgramming / Reprogramming a User Code Erasing a User CodeProgramming Example Exiting the User Program ModeArming/Disarming Turning the system on or off, as follows GlossaryGlossary Priority Zone with Bypass a Priority Zone that can be Trouble System Trouble Action Indication Condition System Trouble Error Codes06-NN 12-NN E19-00 What do I do if For more info TroubleshootingCorrectly without charge to the original purchaser or user Napco Limited Warranty

GEM-K4RF, GEM-K4 specifications

Napco Security Technologies has long been a reputable player in the security industry, and the GEM-K4 and GEM-K4RF panels are prime examples of the company’s commitment to delivering advanced security solutions. The GEM-K4 panel is designed to cater to the needs of both residential and commercial applications, offering a blend of reliability, flexibility, and ease of use.

At the core of the GEM-K4 system is its user-friendly interface, which features a clear 32-character display and an intuitive keypad. Users can easily manage their security system with simple commands, allowing for quick access to essential functions. The panel supports up to 64 zones, accommodating a wide range of sensors and detectors, making it suitable for a variety of settings.

The GEM-K4RF version includes the added benefit of wireless technology, enabling security professionals to install the system with less disruption to existing structures. This wireless feature allows for the integration of up to 16 wireless zones, which can be particularly advantageous in environments where running wires is impractical. The RF capability ensures compatibility with a range of wireless devices, including motion detectors, door/window contacts, and key fobs, enhancing the overall functionality of the security package.

In terms of communication, the GEM-K4 is equipped with a built-in telephone line communicator, facilitating easy connection to monitoring services. Additionally, it supports various communication protocols, including ContactID, enabling seamless integration with central stations for alarm monitoring. This connectivity ensures that users receive prompt notifications and responses in case of alarms or system status updates.

Another significant characteristic of the GEM-K4 and GEM-K4RF systems is their programmability. Users can customize settings through the panel’s programming options or remotely via a compatible application. This allows for tailored functionality according to specific security needs, such as setting schedules for arming or disarming the system and configuring reports for events.

The durability and reliability of the GEM-K4 series are enhanced by its ability to support backup power systems, ensuring that the security features remain operational during power outages. This critical feature is essential for maintaining the safety and security of monitored assets.

Overall, Napco's GEM-K4 and GEM-K4RF panels embody the modern evolution of security technology, combining advanced features with user-centered design to deliver an effective and reliable security solution that meets the diverse needs of users. With its robust capabilities, the GEM-K4 series continues to be a top choice for security professionals looking to enhance the safety of their environments.