Napco Security Technologies GEM-K4RF manual Troubleshooting, What do I do if For more info

Page 31

TROUBLESHOOTING

What do I do if...

For more info...

I try to arm my system but the keypad just displays a P and beeps at me.

 

If the green STATUS light is off, a zone is open. Refer to the Pull Up Zone Directory and find

See Page 6

and secure the open window or door.

 

I try to arm my system but the keypad displays a P and beeps at me. The TROUBLE icon is lit

 

and numbers start scrolling in the display.

 

A System Trouble has been detected. Note the scrolling error codes, which represent the

See Page 7 & 27

trouble. Press Cand you will now be able arm to the system , but the trouble must be

 

fixed as soon as possible.

 

The Fire Alarm is sounding and I don’t know how to turn it off.

 

If a fire is in progress, evacuate the premises immediately! If necessary, call the Fire

See Page 9

Department from an outside telephone. If there is no evidence of a fire, enter your code and

 

press Uto silence the alarm. Note the number of the Zone flashing in the window. Check

 

the smoke detector(s). If a smoke detector tripped, its red alarm indicator light will be on.

 

Press Cto silence the keypad sounder.

 

31

Image 31
Contents Operating Guide for your GEM-K4 and GEM-K4RF Keypads Important Test Your System Weekly IntroductionTable of Contents Keypad Controls & Indicators TROUBLE, INSTANT, INTERIOR, CANCELLED, and Bypass Selectively Bypassing Zones Arming AW AY Setting the Alarm When LeavingArming the System Priority ArmingArea Arming Optional Managers ModeArming Stay Protecting Yourself AT Home Arming in Stay ModeInstant Protection Stay Alarm Indication / Silencing an Alarm Turning OFF the AL ARM Disarming When ReturningDisarming the System Fire-Zone Trouble Fire ProtectionFamily Rehearsal Preparing a Fire Escape PlanImportant! Read Carefully Floorplan Limitations of Fire Alarm Warning System Function Menu P9600 and GEM-P3200 control panels only Function Menu Function Menu Relay Group Central Station Monitoring Communicator FeaturesExit-Delay Restart Advanced FeaturesSecurity Bypass/Unbypass Erasing a User Code Entering the User Program ModeProgramming User Codes Programming / Reprogramming a User CodeProgramming Example Exiting the User Program ModeArming/Disarming Turning the system on or off, as follows GlossaryGlossary Priority Zone with Bypass a Priority Zone that can be Trouble System Trouble Action Indication Condition System Trouble Error Codes06-NN 12-NN E19-00 What do I do if For more info TroubleshootingCorrectly without charge to the original purchaser or user Napco Limited Warranty

GEM-K4RF, GEM-K4 specifications

Napco Security Technologies has long been a reputable player in the security industry, and the GEM-K4 and GEM-K4RF panels are prime examples of the company’s commitment to delivering advanced security solutions. The GEM-K4 panel is designed to cater to the needs of both residential and commercial applications, offering a blend of reliability, flexibility, and ease of use.

At the core of the GEM-K4 system is its user-friendly interface, which features a clear 32-character display and an intuitive keypad. Users can easily manage their security system with simple commands, allowing for quick access to essential functions. The panel supports up to 64 zones, accommodating a wide range of sensors and detectors, making it suitable for a variety of settings.

The GEM-K4RF version includes the added benefit of wireless technology, enabling security professionals to install the system with less disruption to existing structures. This wireless feature allows for the integration of up to 16 wireless zones, which can be particularly advantageous in environments where running wires is impractical. The RF capability ensures compatibility with a range of wireless devices, including motion detectors, door/window contacts, and key fobs, enhancing the overall functionality of the security package.

In terms of communication, the GEM-K4 is equipped with a built-in telephone line communicator, facilitating easy connection to monitoring services. Additionally, it supports various communication protocols, including ContactID, enabling seamless integration with central stations for alarm monitoring. This connectivity ensures that users receive prompt notifications and responses in case of alarms or system status updates.

Another significant characteristic of the GEM-K4 and GEM-K4RF systems is their programmability. Users can customize settings through the panel’s programming options or remotely via a compatible application. This allows for tailored functionality according to specific security needs, such as setting schedules for arming or disarming the system and configuring reports for events.

The durability and reliability of the GEM-K4 series are enhanced by its ability to support backup power systems, ensuring that the security features remain operational during power outages. This critical feature is essential for maintaining the safety and security of monitored assets.

Overall, Napco's GEM-K4 and GEM-K4RF panels embody the modern evolution of security technology, combining advanced features with user-centered design to deliver an effective and reliable security solution that meets the diverse needs of users. With its robust capabilities, the GEM-K4 series continues to be a top choice for security professionals looking to enhance the safety of their environments.