ARMING AW AY: SETTING THE ALARM WHEN LEAVING

Arming the System

1.Check the keypad. The green STATUS light must be on in order to arm.

If the green light is off, the number(s) of any unsecured zone(s) will display in the window. Refer to the pull-up zone list for the location of each problem zone and secure by closing windows, doors, etc.. When all zones are secure, the green STATUS light will come on.

2.Arm the system. Enter your User Code followed by Q. The green STATUS

light will go off, the red ARMED light will come on. Note: If you enter an invalid code, the keypad will beep 4 times, indicating an error. Re-enter your code.

3.Leave the premises. Leave through the exit door before the exit time expires.

Priority Arming

If you attempt to arm the system with a faulted Zone, a 3-second tone will sound at the keypad and “P” will display in the window, indicating that the zones must be secured before the panel can be armed.

Selectively Bypassing Zones

If you cannot locate or repair a faulted zone, it can be removed from the system, or bypassed. Bypass the zone(s) from the system by pressing B, followed by the

zone number (or vice versa). The BYPASS icon will turn on to indicate that the zone has been bypassed. Note: Bypassed zones are unprotected. If a faulted zone cannot be secured, have the system checked as soon as possible. In addition, some systems require a User Code to be entered prior to pressing B(for higher secu-

rity). Please consult with your alarm professional to see if this option is programmed (GEM-P9600/GEM-P3200).

6

Image 6
Contents Operating Guide for your GEM-K4 and GEM-K4RF Keypads Introduction Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators TROUBLE, INSTANT, INTERIOR, CANCELLED, and Bypass Priority Arming Arming AW AY Setting the Alarm When LeavingArming the System Selectively Bypassing ZonesManagers Mode Area Arming OptionalArming in Stay Mode Arming Stay Protecting Yourself AT HomeInstant Protection Stay Turning OFF the AL ARM Disarming When Returning Alarm Indication / Silencing an AlarmDisarming the System Fire Protection Fire-Zone TroublePreparing a Fire Escape Plan Family RehearsalImportant! Read Carefully Floorplan Limitations of Fire Alarm Warning System Function Menu P9600 and GEM-P3200 control panels only Function Menu Function Menu Relay Group Communicator Features Central Station MonitoringAdvanced Features Exit-Delay RestartSecurity Bypass/Unbypass Programming / Reprogramming a User Code Entering the User Program ModeProgramming User Codes Erasing a User CodeExiting the User Program Mode Programming ExampleGlossary Arming/Disarming Turning the system on or off, as followsGlossary Priority Zone with Bypass a Priority Zone that can be System Trouble Error Codes Trouble System Trouble Action Indication Condition06-NN 12-NN E19-00 Troubleshooting What do I do if For more infoNapco Limited Warranty Correctly without charge to the original purchaser or user

GEM-K4RF, GEM-K4 specifications

Napco Security Technologies has long been a reputable player in the security industry, and the GEM-K4 and GEM-K4RF panels are prime examples of the company’s commitment to delivering advanced security solutions. The GEM-K4 panel is designed to cater to the needs of both residential and commercial applications, offering a blend of reliability, flexibility, and ease of use.

At the core of the GEM-K4 system is its user-friendly interface, which features a clear 32-character display and an intuitive keypad. Users can easily manage their security system with simple commands, allowing for quick access to essential functions. The panel supports up to 64 zones, accommodating a wide range of sensors and detectors, making it suitable for a variety of settings.

The GEM-K4RF version includes the added benefit of wireless technology, enabling security professionals to install the system with less disruption to existing structures. This wireless feature allows for the integration of up to 16 wireless zones, which can be particularly advantageous in environments where running wires is impractical. The RF capability ensures compatibility with a range of wireless devices, including motion detectors, door/window contacts, and key fobs, enhancing the overall functionality of the security package.

In terms of communication, the GEM-K4 is equipped with a built-in telephone line communicator, facilitating easy connection to monitoring services. Additionally, it supports various communication protocols, including ContactID, enabling seamless integration with central stations for alarm monitoring. This connectivity ensures that users receive prompt notifications and responses in case of alarms or system status updates.

Another significant characteristic of the GEM-K4 and GEM-K4RF systems is their programmability. Users can customize settings through the panel’s programming options or remotely via a compatible application. This allows for tailored functionality according to specific security needs, such as setting schedules for arming or disarming the system and configuring reports for events.

The durability and reliability of the GEM-K4 series are enhanced by its ability to support backup power systems, ensuring that the security features remain operational during power outages. This critical feature is essential for maintaining the safety and security of monitored assets.

Overall, Napco's GEM-K4 and GEM-K4RF panels embody the modern evolution of security technology, combining advanced features with user-centered design to deliver an effective and reliable security solution that meets the diverse needs of users. With its robust capabilities, the GEM-K4 series continues to be a top choice for security professionals looking to enhance the safety of their environments.