Napoleon Fireplaces GDS 28-N, GS 28-P Do not Kink Flexible Connector, Tion. do not USE Open Flame

Page 13

GAS INSTALLATION

13

Read the section on opening the door in "Finishing" prior to proceeding to prevent damaging the unit.

Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base.

Install rigid black pipe, or 1/2" type L copper tubing with a shutoff valve to the stove.

Seal and tighten the gas line securely to the flex connector supplied.

DO NOT KINK FLEXIBLE CONNECTOR.

Mark the appropriate boxes on the rating plate label to indi- cate the model type depending on the installation (direct vent or B-vent).

CERTIFIED UNDER: CSA 2.33A-M98, ANSI Z21.88A-1998VENTED GAS FIREPLACE HEATER. APPLIANCE MUST BE INSTALLED USING

 

 

 

 

 

BURNER KIT: GDS28BN-KT,OR GDS28BP-KT.

 

 

 

 

 

 

 

 

 

HOMOLOGUE SELON LES NORMES: CSA

2.33A-M98, ANSI Z21.88A-1998FOYER DE CHAUFFAGE AU GAZ AVEC EVACUA-

 

 

TION. CET APPAREIL DOIT ETRE INSTALLE EN UTILISANT UN ENSEMBLE DU BRULEUR: GDS28BN-KT,OU GDS28BP-KT.

 

 

 

 

 

0-4500ft (0-1370m)

 

 

ALTITUDE/ELEVATION

 

0-4500ft (0-1370m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30,000 BTU/h

 

 

INPUT/ALIMENTATION

 

 

26,000 BTU/h

 

 

 

 

 

 

18,000 BTU/h

 

REDUCEDINPUT/ALIMENTATIONREDUITE

 

15,000 BTU/h

 

 

 

 

 

 

 

 

 

 

 

22,500 BTU/h

 

OUTPUT (CDVS280/GDS28)RENDEMENT

 

19,500 BTU/h

 

 

 

24,000 BTU/h

 

OUTPUT (CS280/GS28) RENDEMENT

 

20,800 BTU/h

#37

 

 

ORIFICE/INJECTEUR

 

#53

 

 

 

 

 

 

 

 

 

 

 

DIRECTVENTMODEL

 

 

 

 

 

 

 

 

 

 

CDVS280-N

 

GDS28-N

‘B’VENTMODEL

GDS28-P

 

CDVS280-P

 

 

 

 

 

CS280-N

 

GS28-N

 

GS28-P

 

CS28-P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE28

MODEL GDS28 ONLY: Attach the two leads from the on/ off switch to terminals 1 and 3 located on the gas valve.

FIGURE 29

OL

 

 

HI

O

F

 

 

 

O

 

 

N

F

TOLIP

TOLIP

Do not connect either the wall switch, thermostat or gas valve to electricity (110 volts).

MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP)

PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU(GN)

10" D'UNE COLONNE D'EAU (PG)

MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)

PRESSIOND'ALIMENTATIONMIN:4.5"D'UNECOLONNED'EAU (GN)

11" D'UNE COLONNE D'EAU (PG)

MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)

PRESSIOND'ALIMENTATIONMAX:7"D'UNECOLONNED'EAU (GN)

13" D'UNE COLONNE D'EAU (PG)

FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.

UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENTAVECCETTEUNITE.

WARNING:DONOTADDANYMATERIALTOTHEAPPLIANCE, WHICHWILLCOMEINCONTACTWITHTHEFLAMES,OTHER THANTHATSUPPLIEDBYTHEMANUFACTURERWITHTHEAP- PLIANCE.

AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.

MINIMUMCLEARANCETOCOMBUSTIBLEMATERIAL/ DEGAGEMENTSMINIMAUXDESMATERIAUXCOMBUSTIBLES:

A

7"

D 17½"

B

2"

E 6¼"

C

1"

F 9½"

20"TOCEILINGFROMSTOVETOP 20"ENTRELEDESSUSDUFOYERETLEPLAFOND ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ

MODEL CS280/GS28 APPROVED FOR BEDROOM, &

BEDSITTINGROOMINSTALLATION. HOMOLOGUE POUR IN- STALLATION DANS UNE CHAMBRE A COUCHER, & UN STUDIO.

STEADY STATE EFFICIENCY (NG): 80% FAN OFF / 82%

FAN ON

STEADY STATE EFFICIENCY (LP): 80% FAN OFF / 83%

FAN ON

EFFICACITE CONSTANTE (GN): 80% VENT. ARRETE 82%VENT.FONCTIONNE

EFFICACITECONSTANTE(GP): 80%VENTILATEURARRETE 83% VENTILATEUR FONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /

L'EFFICACITECONSTANTES'APPLIQUENTSEULEMENTAU CANADA.

AFUE (NG/LP) (GN/GP): 66% / 68%

THISAPPLIANCEMUSTBEINSTALLEDUSINGANADAPTER KITGS-150KT.CETAPPAREILDOITETREINSTALLEENUTILI- SANTUNENSEMBLEADAPTATEURGS-150KT.

NOT FOR USE WITH SOLID FUEL

UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE

AVEC CET APPAREIL

MODEL CDVS280/GDS28 APPROVED FOR BEDROOM, BATH-

ROOM & BEDSITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANU- FACTURED HOME INSTALLATIONS, SITES AND COMMUNI- TIES,ANSI/NFPA501A.

HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON IN- STALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.

STEADY STATE EFFICIENCY (NG):75% FAN OFF / 78% FAN ON

STEADYSTATEEFFICIENCY(LP):75% FAN OFF / 79% FAN ON

EFFICACITE CONSTANTE (GN): 75% VENT. ARRETE

78% VENT. FONCTIONNE

EFFICACITE CONSTANTE (GP): 75% VENTILATEUR ARRETE 79%VENTILATEURFONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /

L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA.

AFUE (NG/LP) (GN/GP): 64% / 65%

MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT.

THE APPLIANCE MUST BE VENTED USING THE APPROPRI- ATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLA- TION AND RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.

L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR AS- SURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.

WOLF STEEL LTD

BARRIE, ONTARIO CANADA

MADE IN CANADA / FABRIQUE AU CANADA

SERIALNUMBER GDS28

NO.DESERIE

WS-385-165

Check for gas leaks by brushing on a soap and water solu-

tion. DO NOT USE OPEN FLAME.

For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route a double strand of solid core millivolt wire from the gas stove to the wall switch / millivolt ther- mostat. The recommended maximum lead length de-

pends on the wire size:

WIRE SIZE

MAX. LENGTH

 

 

14

gauge

100 feet

16

gauge

60 feet

18

gauge

40 feet

DIRECT VENT MODEL GDS28: Disconnect the exist- ing wires from terminals 1 and 3 (from the on/off switch) and replace with the leads from the wall switch/millivolt thermostat.

B-VENT MODEL GS28: Disconnect the on/off switch wire from terminal 3 on the valve and the second switch wire from the terminal block. Replace each connection using the wires from the wall switch/millivolt thermostat.

W415-0153 / A / 10.29.01

Image 13
Contents For Your Safety Table of Contents Conditions and Limitations Napoleon GAS Fireplace Presidents Lifetime Limited WarrantyGeneral Instructions Do not clean glass when hotGeneral Information Care of GLASS, and Plated PartsVenting Lengths and AIR TERMI- NAL Locations GDS28 and GS28Offset Installation Example Special Installation Example40 ft. maximum vertical run length Feet InchesFeet FEET† FEET‡Wall and Ceiling Protection Horizontal Venting Installation Vertical Venting InstallationStove Vent Connection Mobile Home InstallationInstalling B Vent Chimney InstallationVent Adaptations Three Types Chimney Systems MAY be Used with This StoveVent Model GS28 only Installing Flashing and Storm CollarCombustion AIR Adding Vent SECWire Size Do not Kink Flexible ConnectorTion. do not USE Open Flame MAX. LengthDoor Closing and Opening LOG Placement InstructionsImpingement and carboning Damage, personal injury or loss of life Operating InstructionsWhat to do if YOU Smell GAS Lighting Instructions Maintenance InstructionsTo Turn OFF GAS Installation Through the Rear Panel For Model GDS28 Installation Through the FIRE- BOXReplacement blower access gasket is required For Model GS28Venturi Adjustment Pilot Burner AdjustmentReplacement Parts Ordering Replacement PartsGDS28 / GS28 Termination Kits ALL KIT DescriptionAccessories / Options Description Replacement PartsW135-0061 W135-0059 W135-0060 W135-0058Model GS28 only Symptom Problem Test SolutionMODELGDS28ONLY Model GDS28 onlyWolf Steel Fireplace Service History W415-0153 / a

GDS 28-N, GDS 28-P, GS 28-P, GS 28-N specifications

Napoleon Fireplaces has established a reputation for manufacturing high-quality, innovative heating solutions that combine efficiency with elegance. Among their impressive lineup, the GDS 28-P, GS 28-P, GS 28-N, and GDS 28-N models are standout options for homeowners seeking both warmth and style. These gas fireplaces excel in functionality while enhancing the aesthetic appeal of any room.

The GDS 28-P and GDS 28-N models are part of Napoleon’s Direct Vent Gas Fireplace series, designed to provide efficient heating without compromising on style. One of the key features of these units is their advanced heating technology. They utilize a direct vent system that draws fresh air from outside while expelling combustion gases safely outdoors. This ensures improved air quality and boosts energy efficiency, heating spaces effectively without depleting indoor oxygen levels.

Both models are equipped with Napoleon’s patented Clean Face Design, which minimizes the frame’s appearance, allowing for an expansive view of the flames. This feature not only enhances the visual appeal of the fireplace but also allows for customizable media options, including decorative glass, logs, or pebbles, giving homeowners the flexibility to create the ambiance they desire.

The GS 28-P and GS 28-N variants, on the other hand, offer a traditional look with modern efficiency. They boast a user-friendly electronic ignition system, ensuring reliable lighting every time. With adjustable flame settings, users can easily control the heat output, making it possible to create the perfect atmosphere for any occasion.

Moreover, all four models are designed with a high efficiency rating, making them an environmentally responsible choice. They are also equipped with Napoleon's advanced safety features, including a safety screen and automatic shut-off, ensuring peace of mind for families.

Durability is another hallmark of Napoleon fireplaces. Constructed with high-quality materials, these models promise longevity and performance, ensuring they remain a centerpiece in the home for years to come. Additionally, the contemporary designs of the GDS 28-P and GS 28-N, alongside the classic aesthetics of the GS 28-P and GS 28-N, allow them to seamlessly integrate into any decor style.

In summary, the Napoleon GDS 28-P, GS 28-P, GS 28-N, and GDS 28-N gas fireplaces stand out for their innovative technologies, user-friendly features, and classic aesthetics. Whether looking for modern elegance or traditional charm, these fireplaces offer a perfect solution, providing warmth and comfort with unparalleled style.