4 GENERAL INSTRUCTIONS

THIS GAS STOVE SHOULD BE INSTALLED AND SERV- ICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area, ie: in Massachusetts State:

The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert.

The appliance off valve must be a “T” handle gas cock.

The flexible connector must not be longer than 36 inches.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct-vent.

In absence of local codes, install to the current CAN1- B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1-1988, and NFPA 54-1988 in the United States. Mobile home installation must conform with local codes or in the absence of local codes, install to the current standard for gas equipped mobile housing CAN/CSA Z240 MH Series in Canada or ANSI Z223.1- 1988 and NFPA 54-1988 in the United States.

Purge all gas lines with the glass door of the stove opened. Assure that a continuous gas flow is at the burner before closing the door.

Under extreme vent configurations, allow several min- utes (5-15) for the flame to stabilize after ignition.

For optimum performance, it is recommended that all horizontal runs have a ¼ inch rise per foot.

Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.

The stove and its individual shutoff valve must be discon- nected from the gas supply piping system during any pres- sure testing of that system at test pressures in excess of

½psig (3.5 kPa). The stove must be isolated from the gas supply piping system by closing its individual manual shut- off valve during any pressure testing of the gas supply pip- ing system at test pressures equal to or less than ½ psig (3.5 kPa)

The stove, when installed with a blower, must be electri- cally connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRICAL CODE in the United States. The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug.

GENERAL INFORMATION

For your satisfaction, this stove has been test-fired to assure its operation and quality!

Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. When the valve is set to "HI", the manifold pres- sure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane. When the fireplace is installed at elevations above 4,500 ft., and in the absence of specific recommendations from the lo- cal authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000 ft.

Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion / con- traction noises during heating up and cooling down cycles are normal and to be expected.

GDS28: Maximum input is 30,000 BTU/hr for natural gas and 26,000 BTU/hr for propane. Maximum output for natural gas is 25,500 BTU/hr at an efficiency of 85% with the fan on and 75% with the fan off. Maximum output for propane is 22,360 BTU/hr at an efficiency of 86% with the fan on and 76% with the fan off. Maximum A.F.U.E. (annual fuel utilization efficiency) rating is 76% for natural gas and 77% for propane. This stove is not approved for closet or recessed installations. It is approved for bathroom, bed- room and bed-sitting room installations.

This stove may be installed in an aftermarket permanently located, manufactured mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

GS28: Maximum input is 30,000 BTU/hr for natural gas and 26,000 BTU/hr for propane. Maximum

output for natural gas is 24,600 BTU/hr at an efficiency of 82% with the fan on and 80% with

the fan off; and 21,600 BTU/hr for propane at an efficiency of 83% with the fan on and 80% with the fan off. This stove is approved for bedroom and bed-sitting room installations.

CARE OF GLASS, AND PLATED PARTS

Do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth.

The glass is 3/16" ceramic glass available from your Na- poleon / Wolf Steel Ltd. dealer.

Do not substitute materials.

Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as required.

Do not clean glass when hot!

If the glass is not kept clean permanent discolouration and / or blemishes may result.

W415-0153 / A / 10.29.01

Image 4
Contents For Your Safety Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Conditions and LimitationsDo not clean glass when hot General InstructionsGeneral Information Care of GLASS, and Plated PartsGDS28 and GS28 Venting Lengths and AIR TERMI- NAL LocationsOffset Installation Example Special Installation Example40 ft. maximum vertical run length Inches FeetFeet FEET† FEET‡Wall and Ceiling Protection Vertical Venting Installation Horizontal Venting InstallationMobile Home Installation Stove Vent ConnectionChimney Installation Installing B VentVent Adaptations Three Types Chimney Systems MAY be Used with This StoveInstalling Flashing and Storm Collar Vent Model GS28 onlyCombustion AIR Adding Vent SECDo not Kink Flexible Connector Wire SizeTion. do not USE Open Flame MAX. LengthDoor Closing and Opening LOG Placement InstructionsImpingement and carboning Damage, personal injury or loss of life Operating InstructionsWhat to do if YOU Smell GAS Lighting Instructions Maintenance InstructionsTo Turn OFF GAS Installation Through the FIRE- BOX Installation Through the Rear Panel For Model GDS28Replacement blower access gasket is required For Model GS28Pilot Burner Adjustment Venturi AdjustmentOrdering Replacement Parts Replacement PartsGDS28 / GS28 Termination Kits ALL KIT DescriptionDescription Replacement Parts Accessories / OptionsW135-0061 W135-0059 W135-0060 W135-0058Symptom Problem Test Solution Model GS28 onlyModel GDS28 only MODELGDS28ONLYWolf Steel Fireplace Service History W415-0153 / a

GDS 28-N, GDS 28-P, GS 28-P, GS 28-N specifications

Napoleon Fireplaces has established a reputation for manufacturing high-quality, innovative heating solutions that combine efficiency with elegance. Among their impressive lineup, the GDS 28-P, GS 28-P, GS 28-N, and GDS 28-N models are standout options for homeowners seeking both warmth and style. These gas fireplaces excel in functionality while enhancing the aesthetic appeal of any room.

The GDS 28-P and GDS 28-N models are part of Napoleon’s Direct Vent Gas Fireplace series, designed to provide efficient heating without compromising on style. One of the key features of these units is their advanced heating technology. They utilize a direct vent system that draws fresh air from outside while expelling combustion gases safely outdoors. This ensures improved air quality and boosts energy efficiency, heating spaces effectively without depleting indoor oxygen levels.

Both models are equipped with Napoleon’s patented Clean Face Design, which minimizes the frame’s appearance, allowing for an expansive view of the flames. This feature not only enhances the visual appeal of the fireplace but also allows for customizable media options, including decorative glass, logs, or pebbles, giving homeowners the flexibility to create the ambiance they desire.

The GS 28-P and GS 28-N variants, on the other hand, offer a traditional look with modern efficiency. They boast a user-friendly electronic ignition system, ensuring reliable lighting every time. With adjustable flame settings, users can easily control the heat output, making it possible to create the perfect atmosphere for any occasion.

Moreover, all four models are designed with a high efficiency rating, making them an environmentally responsible choice. They are also equipped with Napoleon's advanced safety features, including a safety screen and automatic shut-off, ensuring peace of mind for families.

Durability is another hallmark of Napoleon fireplaces. Constructed with high-quality materials, these models promise longevity and performance, ensuring they remain a centerpiece in the home for years to come. Additionally, the contemporary designs of the GDS 28-P and GS 28-N, alongside the classic aesthetics of the GS 28-P and GS 28-N, allow them to seamlessly integrate into any decor style.

In summary, the Napoleon GDS 28-P, GS 28-P, GS 28-N, and GDS 28-N gas fireplaces stand out for their innovative technologies, user-friendly features, and classic aesthetics. Whether looking for modern elegance or traditional charm, these fireplaces offer a perfect solution, providing warmth and comfort with unparalleled style.