Napoleon Fireplaces GS 28-N manual Operating Instructions, Damage, personal injury or loss of life

Page 15

OPERATION / MAINTENANCE 15

Purge all gas lines with the glass door open. As- sure that a continuous gas flow is at the burner before closing the door. Allow several minutes (5-15) for the flame to stabilize after ignition.

MODEL GS28 ONLY: SPILL SWITCH

This is a thermally activated switch, attached to the back of the chimney adapter, which senses the change in temperature and shuts down the gas valve in the event of a severe downdraft of air or a blocked or disconnected vent. It acts as a safety shutoff to prevent a build up of carbon monoxide or an explosion of unburnt gases dur-

ing start up. If the flue is blocked or has no "draw", the spill switch will automatically shut off the supply of gas within about 5-10 minutes.

TAMPERING WITH THE SWITCH CAN RESULT IN CAR- BON MONOXIDE (CO) POISONING AND POSSIBLE DEATH.

MODEL GS28 ONLY: VENTING ACTION

CHECK

A check for correct venting action must be made before the installed stove is left with the customer. Test in the following manner:

1. Close all doors and windows in the room / start exhaust fans in the home / turn fire-

place blower off (if equipped).

2. Set controls to "high" and light

the unit.

 

3. Wait 5 minutes. Light a match

 

and extend it 1" into the hole located

 

above the spill switch bracket on the

 

adapter.

 

4. Venting action is satisfactory if

 

the flame stays lit. Venting action is

FIGURE 32

unsatisfactory if the flame extin-

guishes.

 

5.If venting action is unsatisfactory, turn the unit off, wait 10 minutes and try again. If the match does not stay lit, turn the unit off and check for vent blockage or restric- tion. If necessary, consult with a qualified inspector.

OPERATING INSTRUCTIONS

The on-off switch is located on the back of the unit at the top left corner on models GDS28 and GS28.

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions ex- actly, a fire or explosion may result causing property

damage, personal injury or loss of life.

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

C. Use only your hand to turn the gas control knob / manual shutoff knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service tech- nician. Force or attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de- partment.

W415-0153 / A / 10.29.01

Image 15
Contents For Your Safety Table of Contents Conditions and Limitations Napoleon GAS Fireplace Presidents Lifetime Limited WarrantyCare of GLASS, and Plated Parts Do not clean glass when hotGeneral Instructions General InformationVenting Lengths and AIR TERMI- NAL Locations GDS28 and GS28Special Installation Example Offset Installation Example40 ft. maximum vertical run length FEET‡ InchesFeet Feet FEET†Wall and Ceiling Protection Horizontal Venting Installation Vertical Venting InstallationStove Vent Connection Mobile Home InstallationThree Types Chimney Systems MAY be Used with This Stove Chimney InstallationInstalling B Vent Vent AdaptationsAdding Vent SEC Installing Flashing and Storm CollarVent Model GS28 only Combustion AIRMAX. Length Do not Kink Flexible ConnectorWire Size Tion. do not USE Open FlameLOG Placement Instructions Door Closing and OpeningImpingement and carboning Operating Instructions Damage, personal injury or loss of lifeWhat to do if YOU Smell GAS Maintenance Instructions Lighting InstructionsTo Turn OFF GAS For Model GS28 Installation Through the FIRE- BOXInstallation Through the Rear Panel For Model GDS28 Replacement blower access gasket is requiredVenturi Adjustment Pilot Burner AdjustmentDescription Ordering Replacement PartsReplacement Parts GDS28 / GS28 Termination Kits ALL KITW135-0059 W135-0060 W135-0058 Description Replacement PartsAccessories / Options W135-0061Model GS28 only Symptom Problem Test SolutionMODELGDS28ONLY Model GDS28 onlyWolf Steel Fireplace Service History W415-0153 / a

GDS 28-N, GDS 28-P, GS 28-P, GS 28-N specifications

Napoleon Fireplaces has established a reputation for manufacturing high-quality, innovative heating solutions that combine efficiency with elegance. Among their impressive lineup, the GDS 28-P, GS 28-P, GS 28-N, and GDS 28-N models are standout options for homeowners seeking both warmth and style. These gas fireplaces excel in functionality while enhancing the aesthetic appeal of any room.

The GDS 28-P and GDS 28-N models are part of Napoleon’s Direct Vent Gas Fireplace series, designed to provide efficient heating without compromising on style. One of the key features of these units is their advanced heating technology. They utilize a direct vent system that draws fresh air from outside while expelling combustion gases safely outdoors. This ensures improved air quality and boosts energy efficiency, heating spaces effectively without depleting indoor oxygen levels.

Both models are equipped with Napoleon’s patented Clean Face Design, which minimizes the frame’s appearance, allowing for an expansive view of the flames. This feature not only enhances the visual appeal of the fireplace but also allows for customizable media options, including decorative glass, logs, or pebbles, giving homeowners the flexibility to create the ambiance they desire.

The GS 28-P and GS 28-N variants, on the other hand, offer a traditional look with modern efficiency. They boast a user-friendly electronic ignition system, ensuring reliable lighting every time. With adjustable flame settings, users can easily control the heat output, making it possible to create the perfect atmosphere for any occasion.

Moreover, all four models are designed with a high efficiency rating, making them an environmentally responsible choice. They are also equipped with Napoleon's advanced safety features, including a safety screen and automatic shut-off, ensuring peace of mind for families.

Durability is another hallmark of Napoleon fireplaces. Constructed with high-quality materials, these models promise longevity and performance, ensuring they remain a centerpiece in the home for years to come. Additionally, the contemporary designs of the GDS 28-P and GS 28-N, alongside the classic aesthetics of the GS 28-P and GS 28-N, allow them to seamlessly integrate into any decor style.

In summary, the Napoleon GDS 28-P, GS 28-P, GS 28-N, and GDS 28-N gas fireplaces stand out for their innovative technologies, user-friendly features, and classic aesthetics. Whether looking for modern elegance or traditional charm, these fireplaces offer a perfect solution, providing warmth and comfort with unparalleled style.