This application occurs
FIGURE 11

8WALL AND CEILING PROTECTION

For safe and proper operation of the stove, follow the venting instructions exactly.

HORIZONTAL INSTALLATION: when venting through an exterior wall. FIGURES

4, 5, & 11. Having deter- mined the air terminal lo- cation, cut and frame a hole

in an exterior wall with a minimum square or round opening of 9". (As an alter-

native to framing, a vent pipe shield may be in-

stalled, ensuring a 1" clear- ance to combustibles. See Figure 12.)

For optimum performance, the stove pipe should rise ¼" per foot of run.

1.Mark and cut the vent pipe shield to the determined depth of the combustible wall. Apply a bead of caulking (not supplied) to the framework or to the shield plate (in the case of a finished wall) and secure the shield through the opening to the interior wall. The final location of the vent pipe shield should maintain the required clearance to the 7" vent pipe. Do not fill this cavity with any type of material. Apply a bead of caulking all around and place a firestop spacer over the vent shield to restrict cold air from being drawn into the room or around the stove. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe is installed in its final position, apply sealant between the pipe and the firestop spacer.

OR

FIGURE 12

VERTICAL INSTALLATION: This application occurs when venting through a roof. FIGURE 3.

Installation kits for vari-

FIGURE 13

 

ous roof pitches are

 

available from your Na-

 

poleon dealer. See Ac-

 

cessories to order the

 

specific kit required.

 

1.Determine the air terminal location and move the stove into position. Cut and frame 9 inch openings in the ceiling and the roof to provide the minimum 1 inch clearance be- tween the stove pipe and any combustible material. Try to

 

center the exhaust

 

pipe location midway

 

between two joist to

FIGURE 14

prevent having to cut

them. Use a plumb

 

 

bob to line up the

 

center of the open-

 

ings.

DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL.

A vent pipe shield will prevent any materials such as insu- lation, from filling up the 1" air space around the pipe. FIGURE 15. Nail headers between the joist for extra sup- port.

2.Apply a bead of caulking (not supplied) to the frame- work or to the Wolf Steel vent pipe shield plate or equiva- lent (in the case of a finished ceiling), and secure over the opening in the ceiling. FIGURE 14. A firestop must be placed on the bottom of each framed opening in a roof or ceiling that the venting system passes through. FIGURE 13. Apply a bead of caulking all around and place a firestop spacer over the vent shield to restrict cold air from being drawn into the room or around the stove. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe is installed in its final position, apply sealant between the pipe and the firestop

spacer.

VENT

3. In the attic, after the pipe

PIPE

has been installed, slide the

vent pipe collar down to cover

COLLAR

up the open end of the shield

VENT PIPE

and tighten. This will prevent any

SHIELD

materials, such as insulation,

 

from filling up the 1" air space

 

around the pipe.

FIGURE 15

 

W415-0153 / A / 10.29.01

Image 8
Contents For Your Safety Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Conditions and LimitationsDo not clean glass when hot General InstructionsGeneral Information Care of GLASS, and Plated PartsGDS28 and GS28 Venting Lengths and AIR TERMI- NAL Locations40 ft. maximum vertical run length Special Installation ExampleOffset Installation Example Inches FeetFeet FEET† FEET‡Wall and Ceiling Protection Vertical Venting Installation Horizontal Venting InstallationMobile Home Installation Stove Vent ConnectionChimney Installation Installing B VentVent Adaptations Three Types Chimney Systems MAY be Used with This StoveInstalling Flashing and Storm Collar Vent Model GS28 onlyCombustion AIR Adding Vent SECDo not Kink Flexible Connector Wire SizeTion. do not USE Open Flame MAX. LengthImpingement and carboning LOG Placement InstructionsDoor Closing and Opening What to do if YOU Smell GAS Operating InstructionsDamage, personal injury or loss of life To Turn OFF GAS Maintenance InstructionsLighting Instructions Installation Through the FIRE- BOX Installation Through the Rear Panel For Model GDS28Replacement blower access gasket is required For Model GS28Pilot Burner Adjustment Venturi AdjustmentOrdering Replacement Parts Replacement PartsGDS28 / GS28 Termination Kits ALL KIT DescriptionDescription Replacement Parts Accessories / OptionsW135-0061 W135-0059 W135-0060 W135-0058Symptom Problem Test Solution Model GS28 onlyModel GDS28 only MODELGDS28ONLYWolf Steel Fireplace Service History W415-0153 / a

GDS 28-N, GDS 28-P, GS 28-P, GS 28-N specifications

Napoleon Fireplaces has established a reputation for manufacturing high-quality, innovative heating solutions that combine efficiency with elegance. Among their impressive lineup, the GDS 28-P, GS 28-P, GS 28-N, and GDS 28-N models are standout options for homeowners seeking both warmth and style. These gas fireplaces excel in functionality while enhancing the aesthetic appeal of any room.

The GDS 28-P and GDS 28-N models are part of Napoleon’s Direct Vent Gas Fireplace series, designed to provide efficient heating without compromising on style. One of the key features of these units is their advanced heating technology. They utilize a direct vent system that draws fresh air from outside while expelling combustion gases safely outdoors. This ensures improved air quality and boosts energy efficiency, heating spaces effectively without depleting indoor oxygen levels.

Both models are equipped with Napoleon’s patented Clean Face Design, which minimizes the frame’s appearance, allowing for an expansive view of the flames. This feature not only enhances the visual appeal of the fireplace but also allows for customizable media options, including decorative glass, logs, or pebbles, giving homeowners the flexibility to create the ambiance they desire.

The GS 28-P and GS 28-N variants, on the other hand, offer a traditional look with modern efficiency. They boast a user-friendly electronic ignition system, ensuring reliable lighting every time. With adjustable flame settings, users can easily control the heat output, making it possible to create the perfect atmosphere for any occasion.

Moreover, all four models are designed with a high efficiency rating, making them an environmentally responsible choice. They are also equipped with Napoleon's advanced safety features, including a safety screen and automatic shut-off, ensuring peace of mind for families.

Durability is another hallmark of Napoleon fireplaces. Constructed with high-quality materials, these models promise longevity and performance, ensuring they remain a centerpiece in the home for years to come. Additionally, the contemporary designs of the GDS 28-P and GS 28-N, alongside the classic aesthetics of the GS 28-P and GS 28-N, allow them to seamlessly integrate into any decor style.

In summary, the Napoleon GDS 28-P, GS 28-P, GS 28-N, and GDS 28-N gas fireplaces stand out for their innovative technologies, user-friendly features, and classic aesthetics. Whether looking for modern elegance or traditional charm, these fireplaces offer a perfect solution, providing warmth and comfort with unparalleled style.