Procom ML100HPA, ML060HPA, ML100TPA installation manual Heater produces unwanted odors

Page 16

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

 

POSSIBLE CAUSE

 

 

REMEDY

 

 

 

 

 

 

 

 

 

Heater produces unwanted odors.

1.

Heater

is burning vapors

from

1.

Ventilate room. Stop using odor

 

 

paint,

hair

spray,

glues,

etc.

 

causing products while heater

 

 

(See

IMPORTANT

statement

 

is running.

 

 

 

 

 

above).

 

 

 

 

2.

Locate and correct all leaks(see

 

2 . Gas

leak .

See

Warning

 

Checking Gas Connections,

 

 

Statement at top of page.

 

 

page 10).

 

 

 

 

3.

Low fuel supply.

 

 

3.

Refill supply tank.

 

 

 

 

 

 

 

 

 

 

Heater shuts off in use (ODS operates).

1.

Not enough fresh air is available.

1.

Open window

and/or

door

for

 

 

 

 

 

 

 

 

ventilation.

 

 

 

 

2.

Low line pressure.

 

 

2.

Contact local

propane/LP

gas

 

 

 

 

 

 

 

 

company.

 

 

 

 

3.

ODS/pilot is

partially clogged

3.

Clean ODS/pilot (see

Cleaning

 

 

 

 

 

 

 

 

page 13).

 

 

 

Gas odor exists even when control knob is in OFF position.

1. Gas leak. See Warning

1.

Locate and correct all leaks(see

Statement at top of page.

 

Checking Gas

Connections,

 

 

page 10).

 

2. Control valve defective.

2.

Replace control

valve.

Gas odor during combustion.

1.

Foreign matter between

control

1.

Take

apart

gas tubing

and

 

 

valve and burner.

 

 

remove foreign matter.

 

 

2.

Gas leak. See Warnin

State-

2.

Locate

and

correct all

leaks

 

 

ment at top of page.

 

 

(see

 

Checking

Gas

 

 

 

 

 

Connections, page 10).

 

 

 

 

 

 

Moisture/condensation noticed on

1.

Not enough combustion/ventilation

1.

Refer to Air for Combustion and

windows.

 

air.

 

 

Ventilation requirements ,page

 

 

 

 

 

4.

 

 

 

1 6

Image 16
Contents OWNER’S Operation and Installation Manual ML060HPA ML100HPA ML100TPAP O R TA N T Read this Carbon Monoxide PoisoningProduct Identification Fresh AIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Determining if you have a Confined or Unconfined SpaceAIR for Combustion Ventilation Ventilation AIR Ventilation Air from Inside BuildingInstallation Installation NeedsVentilation AIR Locating HeaterInstallation Fastening Heater to Wall Mounting BracketRemoving Lower Front Panel Of Heater Methods For Attaching Mounting Bracket To WallInstalling Bottom Mounting Screw Attaching to Wall Anchor MethodImportant Install Connecting to GAS SupplyTypical Inlet Pipe Diameters For Your Safety Read Before Lighting Checking GAS ConnectionsOperating Your Heater PILOT/IGNTo Turn OFF GAS to Appliance Shutting Off HeaterShutting Off Burner Only pilot OFFStays lit Inspecting Burner Cleaning MaintenanceOperating Heater Troubleshooting Observed Problem Possible Cause RemedyMaintenance Page 13 or Heater produces unwanted odors Parts Under Warranty SpecificationsModels ML060HPA,ML100HPA, ML100TPA Illustrated Parts Breakdown ML060HPA Parts List ML060HPA KEY Part Number Description QTYODS Parts Available not ShownIllustrated Parts Breakdown ML100HPAParts List ML100HPA ML100TPA Part List ML100TPA

ML060HPA, ML100TPA, ML100HPA specifications

Procom's ML100TPA, ML100HPA, and ML060HPA are cutting-edge amplifiers designed to enhance communication capabilities across various applications. These models are particularly popular in the fields of radio and communication technology, providing reliable performance and superior signal quality.

The ML100TPA is a high-performance, compact transmitter amplifier. It boasts an impressive power output of up to 100 watts, making it suitable for long-range communications. One of its standout features is its wide frequency range, accommodating multiple bands, which allows users to switch between applications seamlessly. The built-in thermal management system ensures stable operation even under heavy loads, preventing overheating and enhancing durability.

The ML100HPA is another powerful offering from Procom, specifically tailored for high-power applications. With a power output similar to the ML100TPA, this amplifier delivers robust performance while maintaining a compact form factor. It includes advanced features such as automatic gain control, ensuring consistent output levels regardless of input variations, which is essential for maintaining signal integrity. Additionally, the ML100HPA integrates an innovative protection circuit that safeguards against mismatches and overloads, enhancing reliability in demanding environments.

On the other hand, the ML060HPA is designed for applications where size and weight are critical considerations without compromising on performance. This model offers a power output of 60 watts, making it ideal for portable setups and mobile operations. Despite its smaller size, the ML060HPA does not skimp on features, including a high-efficiency design that maximizes battery life in mobile applications. It is also equipped with advanced filtering technologies to minimize harmonic distortion and maintain clear communication.

All three models leverage Procom's proprietary technologies, ensuring that they meet the stringent requirements of modern communication systems. They are built with high-quality components to ensure longevity and consistent performance in various environments, from urban settings to remote locations. Moreover, each model is user-friendly, with easy setup and configuration options, making them accessible for both novice and seasoned users.

In summary, the Procom ML100TPA, ML100HPA, and ML060HPA amplifiers represent the pinnacle of communication technology, each offering unique features tailored to specific user needs. Their combination of power, efficiency, and advanced technology makes them invaluable tools for enhancing communication capabilities across a wide range of applications. Whether for broadcasting, emergency communications, or mobile operations, Procom's amplifiers provide the quality and reliability needed to keep users connected.