Monessen Hearth BTU/Hr installation manual Mounting Heater to Optional Mantel

Page 16

INSTALLATION

Continued

Mounting Heater to Optional Hearth Base

1.Lay heater on its back on a table with the bottom of heater overhanging the edge of the table.

2.Remove 2 shipping screws in bottom of heater. Discard shipping screws.

3.Line up mounting holes on top of hearth base with holes in bottom of heater (see Figure 11).

4.Using a Phillips screwdriver, secure hearth base to heater with four sheet metal screws (see Figure 11).

5.Stand heater up on base.

6.Place hearth insert in hearth base as shown in Figure 12.

7.Assemble brass trim (see steps 1 through 7 under “Assembling and Attaching Brass Trim,” page 7).

8.Slide base trim on heater base. Attach brass trim to base with two brass screws included as shown in Figure 12.

Securing Hearth Base to Floor

Bottom of Heater

Shipping Screw

 

Mounting

Holes for

Holes

Sheet Metal

Securing Heater

to Floor

Screws

Figure 11 - Attaching Heater to Hearth Base

1.Position hearth base in desired location. Mark holes for drilling (See Figure 11). Remove hearth base.

2.For carpeted floor, make a small cut with a sharp knife at marked locations before drilling. If securing to a wood floor, drill a 3/4" deep hole using a 1/8" diameter drill bit. Do not use anchors in wood floors. If securing to a concrete floor, drill a 1 3/8" deep hole using a 5/32" diameter concrete drill bit. Completely insert anchors into each hole.

3.Mount heater to hearth base following steps under Mounting Heater to Optional Hearth Base. After mount- ing heater, position heater and hearth base over drilled holes. With slotted screwdriver, secure hearth base to floor with four wood screws.

Screw

Brass Base

Trim

C. MOUNTING HEATER TO OPTIONAL MANTEL.

Figure 12 - Placing Hearth Insert on Heater

Base and Attaching Brass Base Trim

See Instructions Included With Mantel Kit.

 

IMPORTANT: Only use the optional mantels specified in this manual. See “Accessories,” pages 28 and 29 for proper mantel kits. This heater is only approved for use with mantels designed for this heater. Do not use these mantels with any other product.

16

49D0090

Image 16
Contents Read and Save These Instructions DHHP/NTWhat to do if YOU Smell GAS Contents Important Safety Information Installer OwnerImportant Safety Information Specifications and Local Codes Natural GASPROPANE/LPG Local CodesAssembly Installing Hood Product Identification and AssemblyUnpacking Assembly Installing LogsAttaching Brass Front Trim to Front PanelFresh AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if YOU have a Confined or Unconfined SpaceFrom Inside Building Ventilation AIRVentilation AIR from Outdoors Installation Installation ItemsLocating Heater Mounting Clearances As Viewed From Front of Heater Installation Options Maintain minimum clearances shown . If you can, provide greaterClearances from floor and joining wall Mounting Heater to WallMounting Heater Onto Mounting Bracket Mounting Heater to Optional Mantel Mounting Heater to Optional Hearth BaseConnecting to GAS Supply Pressure Testing Gas Supply Piping System Checking GAS ConnectionsOperating Instructions What to do if YOU Smell GASDo not try to adjust heating levels by Using the equipment shutoff valveShutting OFF Heater Shutting OFF Burner only Pilot Stays LITPilot Flame Pattern Inspecting HeaterBurner Flame Pattern Troubleshooting Observed Problem Possible Cause RemedyTroubleshooting Observed Remedy Problem Possible CauseTroubleshooting Cleaning and Maintenance Cleaning Burner Injector Holder Pilot AIR Inlet HoleCleaning Turn off heater and let cool beforeIllustrated Parts List Description QTY Dhhnt DhhptAccessories Brass Louvers LbhhHearth Base HHB Corner Surrounds With HearthThermostat Forced AIR Blower Blohh 49D0090 49D0090 Five Year Warranty Lifetime WarrantyBasic Warranty