Napoleon Fireplaces Comprehensive Guide to BGD40 Napoleon Fireplace Installation and Operation

Page 26

26

OPTIONAL BLOWER INSTALLATION

INSTALLATION TO BE DONE BY A QUALIFIED IN- STALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

Remove the "Z" shaped mounting bracket secured to the burner, by the pilot. Remove the thermodisc from the bracket supplied in the blower kit and attach to

Remove the blower from its mounting bracket and attach to the bracket supplied with the fireplace. This bracket is found secured on the mounting stud located at the bot- tom of the vent side wall.

b l

a

c

k

 

d

 

re

white

FIGURE58

the mounting bracket. Attach the connectors from the black and white wires to the

thermodisc.FIGURE62

Do not overtighten thermodisc or distort housing.

Attach the connectors from the black and red wires to the blower. Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle.

FIGURE63

FIGURE59

FIGURE60

The blower bracket contains two holes that allow the blower to be positioned away from the intended gas supply hole.

Position the vibration reducing pad, centred, onto the threaded stud, piercing a hole into the pad. The blower must be able to be positioned entirely onto the pad.

Tilt the blower onto its side and slide it past the controls. Position the blower under the clip and onto the stud. Se- cure with a wing nut.

The wire harness provided in this kit is a universal har- ness. When installed, ensure that any excess wire is contained, preventing it from making contact with mov- ing or hot objects.

Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.

Because the blower is thermally activated, when turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run for approximately 30 - 45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat.

FIGURE61

W415-0299 /C / 03.12.03

Image 26
Contents GAS Fired Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information IntroductionGeneral Instructions Care of GLASS, and Plated PartsDimensions Venting Venting LengthsAIR Terminal Installations Venting Application Flowchart Horizontal Termination VerticalPeriscope Termination Typical Vent InstallationsSpecial Vent Installations Horizontal Termination Definitions Elbow Vent Length ValuesFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet Example Vertical Termination 90 H2 45 H1Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Venting Peninsula Installation ProcedureCountertop / BAR Installation FramingFinishing Brick Panel InstallationFacing OPEN-END Installation Procedure = 25¼ minus finishing material thickness each sideSEE-THROUGH Installation Procedure Venting FacingVent Framing Dimensions Horizontal Vent Off Fireplace Vertical Vent Off FireplaceVertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Fireplace Vent ConnectionFinishing GAS InstallationMantle Installation LOG Placement Locating PinsGvfl Installation Glowing Embers Door InstallationLogo Placement Charcoal EmbersL36 Louvre Installation END Door Installation Steel LIP DoorOptional Blower Installation Do not overtighten thermodisc or distort housingOperation / Maintenance MaintenanceVenturi Adjustment AdjustmentsPilot Burner Adjustment Restricting Vertical VentsReplacements Components Common to ALL UnitsW415-0299 /C Accessories Trouble Shooting Guide Symptom Problem Test SolutionProblem Test Solution Refer to Main Burner Goes OUT Pilot Stays onWolf Steel Fireplace Service History W415-0299/C/03.12.03 W415-0299/C/03.12.03
Related manuals
Manual 36 pages 35.09 Kb

BGD40-P, BGD40-N specifications

Napoleon Fireplaces has long been a name synonymous with quality and innovation in the realm of hearth products. Among its impressive lineup, the BGD40-N and BGD40-P models stand out for their blend of performance, aesthetics, and technology, making them ideal choices for homeowners seeking both efficiency and style.

The BGD40-N is a natural gas fireplace, designed with an emphasis on creating a warm and inviting atmosphere. One of its main features is the glass front that enhances its visual appeal while providing a clear view of the mesmerizing flames. This model is equipped with Napoleon's patented PHAZER log set, which mimics the appearance of real wood, further enriching the realistic ambiance.

In contrast, the BGD40-P is a propane version of the fireplace, offering similar design aesthetics and functionality tailored to propane users. Both models boast a high-efficiency rating, which means they maximize heat output while minimizing gas consumption. This efficiency not only reduces energy costs but also makes them environmentally friendly options for home heating.

One of the standout technologies featured in the BGD40 series is the advanced electronic ignition system. This system ensures that igniting the fireplace is a hassle-free experience, even during power outages when using the optional battery backup. Furthermore, the exclusive Heat Management System provides optimal airflow and distribution of heat, ensuring that living spaces are warmed effectively and consistently.

Safety features are paramount in both models, with a built-in safety shut-off system that enhances peace of mind for users. Additionally, the adjustable flame height allows homeowners to customize their experience, ranging from a gentle glow to a roaring fire.

The design flexibility of the BGD40-N and BGD40-P allows them to fit seamlessly into various home décors, complementing both modern and traditional interiors. With their sleek lines and customizable options, including different media choices, these fireplaces serve as focal points in any room.

Installation is straightforward, with options available for both vented and direct vent configurations. This versatility means they can be installed in various locations, making them suited for new builds or retrofitting into existing structures.

In summary, Napoleon Fireplaces' BGD40-N and BGD40-P models deliver on aesthetics, efficiency, and innovative technology. With their realistic flame effects, user-friendly features, and commitment to safety, they are excellent choices for those seeking to enhance the comfort and ambiance of their homes.