2 MAKE WATER SUPPLY CONNECTIONS
Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies. Connection on fitting supplies are 3/8" compression. Connect left supply (Marked with a Red Stripe) to Hot and right supply (Marked with Blue Stripe) to Cold wall supply. Use adjustable wrench to tighten connections. Do not over tighten.
Faucet supplies are
B L U E
R E DS T R I P E S T R I P E
2
Note: If additional supply length is required, installer must
purchase additional parts1 COLD separately.
Important: If SUPPLY HOSES
(1, 2) are too long, loop asHOT illustrated to avoid kinking.
3 TEST INSTALLED FAUCET
Move HANDLE (1) into "off" position.
Unthread AERATOR (2) from SPOUT (3).
Turn on water supplies and check connections for leaks.
Operate HANDLE (1) on and off, hot and cold to flush water lines thoroughly. Replace AERATOR (2).
Check all drain connections for leaks.
Move HANDLE (1) to "off" position.
3
2
1
HOT & COLD SUPPLIES
M 9 6 8 5 7 6