Napoleon Fireplaces BGD40-N, BGD40-P manual OPEN-END Installation Procedure

Page 16

16

OPEN-END INSTALLATION PROCEDURE

VENTING

Refer to pages 6-13. All venting must have a minimum clearance of 1" to combustible.

FRAMING

See Page 18 for additional framing dimensions. Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.

It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes.

FIGURE20

A

A = 25¼" minus finishing material thickness each side.

NOTE: LEFT CORNER UNIT ILLUSTRATED

To install the fireplace face flush with the finished wall, position the framework to accommodate the thickness of the finished wall.

BRICK PANEL INSTALLATION

Install the base panels as illustrated in steps 1-4 on page

15.The side panel sits under the bracket tab. Holding the side panel in position, bend down the tab to secure. DE- TAIL 6.

FIGURES21a-c

STEP 5

RETAINER

DETAIL6STEP 6

FACING

Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.

It is not necessary to install a hearth extension with this fireplace system.

When roughing in the fireplace, raise the fireplace to ac- commodate for the thickness of the finished floor materi- als, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower access door and

the installation of many decorative flashing accessories.

Objects placed in front of the fireplace should be kept a minimum of 48" away from the glass front faces.

FINISHING

Refer to pages 22-25 for complete instructions regarding mantle requirements and installations, log placement, glass door and upper and lower louvre attachments.

FIGURE22

DRYWALL

DRYWALL

 

5" MIN

W415-0299/C/03.12.03

Image 16
Contents GAS Fired Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Introduction General InstructionsGeneral Information Care of GLASS, and Plated PartsDimensions Venting Venting LengthsAIR Terminal Installations Venting Application Flowchart Horizontal Termination VerticalSpecial Vent Installations Typical Vent InstallationsPeriscope Termination Horizontal Termination Definitions Elbow Vent Length ValuesFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet Example Vertical Termination 90 H2 45 H1Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Peninsula Installation Procedure Countertop / BAR InstallationVenting FramingFacing Brick Panel InstallationFinishing OPEN-END Installation Procedure = 25¼ minus finishing material thickness each sideSEE-THROUGH Installation Procedure Venting FacingVent Framing Dimensions Horizontal Vent Off Fireplace Vertical Vent Off FireplaceHorizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Fireplace Vent ConnectionMantle Installation GAS InstallationFinishing LOG Placement Locating PinsGlowing Embers Door Installation Logo PlacementGvfl Installation Charcoal EmbersL36 Louvre Installation END Door Installation Steel LIP DoorOptional Blower Installation Do not overtighten thermodisc or distort housingOperation / Maintenance MaintenanceAdjustments Pilot Burner AdjustmentVenturi Adjustment Restricting Vertical VentsReplacements Components Common to ALL UnitsW415-0299 /C Accessories Trouble Shooting Guide Symptom Problem Test SolutionProblem Test Solution Refer to Main Burner Goes OUT Pilot Stays onWolf Steel Fireplace Service History W415-0299/C/03.12.03 W415-0299/C/03.12.03
Related manuals
Manual 36 pages 35.09 Kb

BGD40-P, BGD40-N specifications

Napoleon Fireplaces has long been a name synonymous with quality and innovation in the realm of hearth products. Among its impressive lineup, the BGD40-N and BGD40-P models stand out for their blend of performance, aesthetics, and technology, making them ideal choices for homeowners seeking both efficiency and style.

The BGD40-N is a natural gas fireplace, designed with an emphasis on creating a warm and inviting atmosphere. One of its main features is the glass front that enhances its visual appeal while providing a clear view of the mesmerizing flames. This model is equipped with Napoleon's patented PHAZER log set, which mimics the appearance of real wood, further enriching the realistic ambiance.

In contrast, the BGD40-P is a propane version of the fireplace, offering similar design aesthetics and functionality tailored to propane users. Both models boast a high-efficiency rating, which means they maximize heat output while minimizing gas consumption. This efficiency not only reduces energy costs but also makes them environmentally friendly options for home heating.

One of the standout technologies featured in the BGD40 series is the advanced electronic ignition system. This system ensures that igniting the fireplace is a hassle-free experience, even during power outages when using the optional battery backup. Furthermore, the exclusive Heat Management System provides optimal airflow and distribution of heat, ensuring that living spaces are warmed effectively and consistently.

Safety features are paramount in both models, with a built-in safety shut-off system that enhances peace of mind for users. Additionally, the adjustable flame height allows homeowners to customize their experience, ranging from a gentle glow to a roaring fire.

The design flexibility of the BGD40-N and BGD40-P allows them to fit seamlessly into various home décors, complementing both modern and traditional interiors. With their sleek lines and customizable options, including different media choices, these fireplaces serve as focal points in any room.

Installation is straightforward, with options available for both vented and direct vent configurations. This versatility means they can be installed in various locations, making them suited for new builds or retrofitting into existing structures.

In summary, Napoleon Fireplaces' BGD40-N and BGD40-P models deliver on aesthetics, efficiency, and innovative technology. With their realistic flame effects, user-friendly features, and commitment to safety, they are excellent choices for those seeking to enhance the comfort and ambiance of their homes.