Monessen Hearth KHLDV SERIES manual Final Installation, BRICK, Light BULB, and Lens Placement

Page 30

FINAL INSTALLATION

BRICK, LIGHT BULB, AND LENS PLACEMENT

1.Remove the trapezoidal light shroud located at the back of the firebox by unfastening the three screws.

2.Disassemble the trapezoidal light shroud by unfastening the four screws which secure the front to the back. Set lens with the orange painted surface toward the bottom. Center the lens right to left. Reassemble the front to the back and set the side.

3.Place the right side panel by sliding it at an angle to clear the grate. Set the panel straight up and bring forward until it comes in contact with the reverse bend located at the front of the firebox. Use one of the brackets and screws provided to secure the panel in place.

4.Place the rear lower panel by setting it over the channel behind the light socket. Make sure the grout line lines up with the one on the side.

5.NOTE: Have the left panel bracket and screw handy before installing the rear upper panel in place. Place the rear upper panel in place by resting it over the rear lower panel and sliding it behind the right side panel. While holding the rear upper panel in place, slide the left panel at an angle to clear the grate. Set the left side panel straight up and release the rear upper panel. Secure the left side panel in place using the second bracket and screw provided in the kit.

6.Place the front hearth brick simultaneously and pull toward the front away from the burner. This is critical for balanc- ing air flow around the front burner.

7.Install the halogen light bulb provided with the unit (inside the log set). Do not touch light bulb directly with fin- gers.

8.Replace the trapezoidal light shroud removed in step #1 by sliding it over the light bulb and sockets. Be careful not to damage the light bulb. Align the holes on the deflector with the hole on the rear channel and secure in place.

ROCK WOOL PLACEMENT

1.Place rock wool on the front burner to provide glowing embers. For best results, pull the rock wool apart into dime size pieces and place on top of burner. Also place the same size ember over the carry over parts on the rear burner. Do NOT place embers over open slots on the rear burner.

2.Distribute one layer of rock wool to cover the burner. See Figure 34 and next page.

3.Place the logs on the burner. See Log Placement below. Light unit and after 15 minutes, check burner flame and glow. See Burner Flame, page 40.

LIGHT

 

RHEOSTAT

LIGHT

 

 

 

 

TERMINAL

 

 

BLOCK

 

 

CK

WHITE

BLACK

BLA

BLACK

JUNCTION

 

 

 

BOX

 

WHITE

BLUE

 

 

 

 

WHITE

 

 

LIGHT

Figure 33 - Light wiring diagram

WARNING

Do not use the entire bag of rock wool

 

 

to cover the burner. This could cause

 

the flame to burn poorly and may lead

 

to sooting.

 

 

Figure 34 - Rockwool placement

30

73D0024

Image 30
Contents Khldv Series Direct Vent GAS Fireplace Contents Important Safety Information InstallerOwner Gas is commonly known as Never connect unit to privateNon-utility gas wells. This Wellhead gasCode Approval Product Features and Code ApprovalProduct Specifications Listed Vented GAS Fireplace HeaterOrifice SIZES, Pressures and BTUs PRE-INSTALLATION InformationInstalling Above 2000 Feet Before YOU StartFirebox Framing Fireplace Dimensions Fireplace DimensionsCold Climate Insulation Fireplace LocationClearances Clearances to CombustiblesMantel Clearances Securing Fireplace to Floor or Framing Securing Fireplace to Floor and Framing StudsInstallation Precautions Installation InformationVent Installation Finishing MaterialVent Installation Combustible Clearances for Vent PipeFor Horizontal Termination Installation PlanningInstalling a Vent System in AN Outside Chase For Vertical TerminationHorizontal Vent Termination Location Minimum DistancesHOW to USE the Vent Graph FeetVERTICAL/HORIZONTAL Termination Configurations Maximum Three 3 90 ElbowsVERTICAL/HORIZONTAL Termination Configurations Horizontal Run ReductionBelow Grade Installations Below Grade InstallationVertical THROUGH-THE-ROOF Applications Support Straps for Horizontal RunsInstallation for Vertical Termination Flat Ceiling InstallationTermination Heights for Vents Above Flat or Sloped Roofs Roof PitchFireplace Installation Installing GAS Piping to Fireplace / Burner System LocationCheck GAS Type Only persons licensed to work with Gas piping may make the necessaryGas connections to this appliance Do not use open flame to check for Checking GAS Pressure and Electrical InstallationElectrical Wiring Gas leaksRemote Wall Switch Installation Remote Wall Mounted SwitchOptional FAN/BLOWER System Junction Box Wiring Diagram Optional FAN/BLOWER SystemBlower Access Plates Glass Removal Glass Frame RemovalFinal Installation BRICK, Light BULB, and Lens PlacementRock Wool Placement LOG Placement Burner Grate Assembly StepFinal Installation What to do if YOU Smell GAS Leak TestingOperating Instructions MILLI-VOLT Initial LightingApproved Leak Testing Method Main Burner Switch Lighting the BurnerPilot Position Pilot Flame Cleaning and MaintenanceBURNER, Pilot and Control Compartment BurnerLogs Vent SystemGlass Door Rock WoolTroubleshooting Symptom Possible Cause ActionStanding Pilot Ignition Troubleshooting Illustrated Parts Lists Firebox Components and AccessoriesDescription Qty Standing Pilot Millivolt Control KHLDV400NV KHLDV400PV KHLDV500NV KHLDV500PV Illustrated Parts List Vent Components for 5 XLogs Special Requirements Special Requirements 73D0024 73D0024 73D0024 73D0024 Lifetime Warranty Five Year WarrantyBasic Warranty

KHLDV SERIES specifications

The Monessen Hearth KHLDV Series is a standout line of direct vent gas fireplaces designed to elevate both the aesthetics and functionality of residential spaces. Distinguished by their contemporary design and impressive heating capabilities, these units cater to homeowners seeking a modern solution for efficient warmth and ambiance.

One of the primary features of the KHLDV Series is its versatile design options. Available in various sizes and styles, these fireplaces can seamlessly integrate into diverse interior décor themes. The clean face design allows for a wide viewing area of the flames, providing an unobstructed view that enhances the overall experience. The elegant finish options, ranging from sleek black to decorative trim, make it easy for consumers to customize their unit to suit their personal style.

The KHLDV Series is also noted for its advanced heating technology. Utilizing direct venting, it ensures efficient operation while minimizing heat loss. This technology allows the fireplace to draw air from outside for combustion, which not only improves energy efficiency but also maintains optimal indoor air quality by preventing the depletion of oxygen in the living area. The balanced flue design further ensures that harmful gases are vented safely outside, giving homeowners peace of mind.

Control is another significant advantage of the KHLDV Series. Equipped with a multi-function remote control system, users can easily adjust the flame height and heat output to achieve their desired ambiance and comfort levels. This intuitive control system enhances the overall user experience, allowing homeowners to create a cozy environment with minimal effort.

Safety features are also a crucial consideration in the design of the KHLDV Series. Each unit comes with a built-in safety pilot system that ensures the fireplace operates reliably and safely, providing an additional layer of security for families. The high-quality materials used in construction further enhance durability, ensuring that the fireplace can withstand the test of time.

In summary, the Monessen Hearth KHLDV Series is a perfect blend of style, efficiency, and safety. With its sleek design, advanced heating technology, user-friendly control, and robust safety features, this series transforms any living space into a warm and inviting sanctuary. Ideal for modern homes, the KHLDV Series stands out as a compelling choice for those looking to enhance their home with a functional and elegant fireplace.