TROUBLESHOOTING

 

 

 

 

 

STANDING PILOT IGNITION

 

 

SYMPTOM

POSSIBLE CAUSE

ACTION

 

4.

Frequent pilot outage

A. Pilot flame may be too high or

A. Clean and adjust the pilot flame for maximum flame impinge-

 

 

 

problem.

 

too low, causing pilot safety

ment on thermocouple.

 

 

 

 

 

to drop out

 

 

 

 

 

 

 

5. The pilot and main

A. Inner vent pipe leaking

A. Check for flue product leak. Replace defective pipe section.

 

 

 

burner extinguish

 

exhaust gases back into

 

 

 

 

while in operation

 

system

 

 

 

 

 

B.

Horizontal vent improperly

B. Check horizontal-venting piping is running upward 1/4" per foot.

 

 

 

 

 

pitched

Do not run the pipe level or downward.

 

 

 

 

C.

Improper vent cap installation

C. Check for proper installation and freedom from debris or

 

 

 

 

 

 

blockage.

 

 

 

 

 

 

 

6.

Glass Soots

A. Flame impingement on logs

A. Install log set per the instructions

 

 

 

 

 

 

Inspect the injector and air intake area. Make sure this area does

 

 

 

 

 

 

not have any blockage from debris and clean.

 

 

 

 

 

 

Check gas supply.

 

 

 

 

 

 

7. Flame burn blue and

A. Insufficient oxygen being

A. Ensure that the vent cap is installed properly and free of debris.

 

 

 

lifts off burner (ghost-

 

supplied

Ensure that the vent system joints are tight and have no leaks.

 

 

 

ing)

 

 

Ensure that no debris has been blocking the inner air intake at the

 

 

 

 

 

 

bottom back of the combustion chamber. Ensure that the glass is

 

 

 

 

 

 

properly secure and latch.

 

 

 

 

 

 

 

 

73D0024

39

Image 39
Contents Khldv Series Direct Vent GAS Fireplace Contents Important Safety Information InstallerOwner Wellhead gas Never connect unit to privateNon-utility gas wells. This Gas is commonly known asListed Vented GAS Fireplace Heater Product Features and Code ApprovalProduct Specifications Code ApprovalBefore YOU Start PRE-INSTALLATION InformationInstalling Above 2000 Feet Orifice SIZES, Pressures and BTUsFirebox Framing Fireplace Dimensions Fireplace DimensionsFireplace Location Cold Climate InsulationClearances Clearances to CombustiblesMantel Clearances Securing Fireplace to Floor and Framing Studs Securing Fireplace to Floor or FramingFinishing Material Installation InformationVent Installation Installation PrecautionsCombustible Clearances for Vent Pipe Vent InstallationFor Vertical Termination Installation PlanningInstalling a Vent System in AN Outside Chase For Horizontal TerminationMinimum Distances Horizontal Vent Termination LocationFeet HOW to USE the Vent GraphMaximum Three 3 90 Elbows VERTICAL/HORIZONTAL Termination ConfigurationsHorizontal Run Reduction VERTICAL/HORIZONTAL Termination ConfigurationsBelow Grade Installation Below Grade InstallationsSupport Straps for Horizontal Runs Vertical THROUGH-THE-ROOF ApplicationsFlat Ceiling Installation Installation for Vertical TerminationRoof Pitch Termination Heights for Vents Above Flat or Sloped RoofsFireplace Installation Installing GAS Piping to Fireplace / Burner System LocationCheck GAS Type Only persons licensed to work with Gas piping may make the necessaryGas connections to this appliance Gas leaks Checking GAS Pressure and Electrical InstallationElectrical Wiring Do not use open flame to check forRemote Wall Switch Installation Remote Wall Mounted SwitchOptional FAN/BLOWER System Optional FAN/BLOWER System Junction Box Wiring DiagramBlower Access Plates Glass Frame Removal Glass RemovalFinal Installation BRICK, Light BULB, and Lens PlacementRock Wool Placement Burner Grate Assembly Step LOG PlacementFinal Installation Initial Lighting Leak TestingOperating Instructions MILLI-VOLT What to do if YOU Smell GASApproved Leak Testing Method Main Burner Switch Lighting the BurnerPilot Position Burner Cleaning and MaintenanceBURNER, Pilot and Control Compartment Pilot FlameRock Wool Vent SystemGlass Door LogsTroubleshooting Symptom Possible Cause ActionStanding Pilot Ignition Troubleshooting Firebox Components and Accessories Illustrated Parts ListsDescription Qty Standing Pilot Millivolt Control KHLDV400NV KHLDV400PV KHLDV500NV KHLDV500PV Vent Components for 5 X Illustrated Parts ListLogs Special Requirements Special Requirements 73D0024 73D0024 73D0024 73D0024 Lifetime Warranty Five Year WarrantyBasic Warranty

KHLDV SERIES specifications

The Monessen Hearth KHLDV Series is a standout line of direct vent gas fireplaces designed to elevate both the aesthetics and functionality of residential spaces. Distinguished by their contemporary design and impressive heating capabilities, these units cater to homeowners seeking a modern solution for efficient warmth and ambiance.

One of the primary features of the KHLDV Series is its versatile design options. Available in various sizes and styles, these fireplaces can seamlessly integrate into diverse interior décor themes. The clean face design allows for a wide viewing area of the flames, providing an unobstructed view that enhances the overall experience. The elegant finish options, ranging from sleek black to decorative trim, make it easy for consumers to customize their unit to suit their personal style.

The KHLDV Series is also noted for its advanced heating technology. Utilizing direct venting, it ensures efficient operation while minimizing heat loss. This technology allows the fireplace to draw air from outside for combustion, which not only improves energy efficiency but also maintains optimal indoor air quality by preventing the depletion of oxygen in the living area. The balanced flue design further ensures that harmful gases are vented safely outside, giving homeowners peace of mind.

Control is another significant advantage of the KHLDV Series. Equipped with a multi-function remote control system, users can easily adjust the flame height and heat output to achieve their desired ambiance and comfort levels. This intuitive control system enhances the overall user experience, allowing homeowners to create a cozy environment with minimal effort.

Safety features are also a crucial consideration in the design of the KHLDV Series. Each unit comes with a built-in safety pilot system that ensures the fireplace operates reliably and safely, providing an additional layer of security for families. The high-quality materials used in construction further enhance durability, ensuring that the fireplace can withstand the test of time.

In summary, the Monessen Hearth KHLDV Series is a perfect blend of style, efficiency, and safety. With its sleek design, advanced heating technology, user-friendly control, and robust safety features, this series transforms any living space into a warm and inviting sanctuary. Ideal for modern homes, the KHLDV Series stands out as a compelling choice for those looking to enhance their home with a functional and elegant fireplace.