Monessen Hearth KHLDV SERIES manual Cold Climate Insulation, Fireplace Location

Page 9

PRE-INSTALLATION INFORMATION

NOTE

COLD CLIMATE INSULATION

If you live in a cold climate, seal all cracks around your appliance, and wherever cold air could enter the room, with noncombustible material. It is especially important to insulate the outside chase cavity between the studs and under the floor on which the appliance rests, if the floor is above ground level.

FIREPLACE LOCATION

Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspec- tions.

The following factors should be taken into consideration:

Clearance to side-wall, ceiling, woodwork, and windows. Minimum clearances to combustibles must be maintained.

This fireplace may be installed along a wall, across a corner, or use an exterior chase. See Figure 4 for suggested loca- tions.

Location should be out of high traffic areas and away from furniture and draperies due to heat from appliance.

Never obstruct the front opening of the fireplace.

Do not install in the vicinity where gasoline or other flammable liquids may be stored.

Vent pipe routing. See Venting section found in this manual for allowable venting configurations.

These units can be installed in a bedroom. See National Fuel Gas Code ANSI Z233.1/NFPA 54 — (current edition), the Uniform Mechanical Code — (current edition), and Local Building Codes for specific installation requirements.

These units can be installed in a bathroom.

A

Flat on Wall

B

Cross Corner

C

Island**

D

Room Divider*

E

Flat on Wall Corner*

F

Chase Installation

Y

6" Minimum

 

 

E

A

B

Y

 

 

 

 

 

X

 

 

C

D

 

 

Y

 

 

 

F

 

Figure 4 - Locating Gas Fireplace

**Island (C) and room divider (D) installation is possible as long as the horizontal portion of vent system (X) does not exceed 20'. See Installing Horizontal Termination Configuration on pages 18 and 19.

*When you install your fireplace in (D) room divider or (E) flat on wall corner positions (Y), a minimum of 6" clearance must be maintained from perpendicular wall and front of fireplace.

73D0024

9

Image 9
Contents Khldv Series Direct Vent GAS Fireplace Contents Important Safety Information InstallerOwner Non-utility gas wells. This Never connect unit to privateGas is commonly known as Wellhead gasProduct Specifications Product Features and Code ApprovalCode Approval Listed Vented GAS Fireplace HeaterInstalling Above 2000 Feet PRE-INSTALLATION InformationOrifice SIZES, Pressures and BTUs Before YOU StartFirebox Framing Fireplace Dimensions Fireplace DimensionsFireplace Location Cold Climate InsulationClearances Clearances to CombustiblesMantel Clearances Securing Fireplace to Floor and Framing Studs Securing Fireplace to Floor or FramingVent Installation Installation InformationInstallation Precautions Finishing MaterialCombustible Clearances for Vent Pipe Vent InstallationInstalling a Vent System in AN Outside Chase Installation PlanningFor Horizontal Termination For Vertical TerminationMinimum Distances Horizontal Vent Termination LocationFeet HOW to USE the Vent GraphMaximum Three 3 90 Elbows VERTICAL/HORIZONTAL Termination ConfigurationsHorizontal Run Reduction VERTICAL/HORIZONTAL Termination ConfigurationsBelow Grade Installation Below Grade InstallationsSupport Straps for Horizontal Runs Vertical THROUGH-THE-ROOF ApplicationsFlat Ceiling Installation Installation for Vertical TerminationRoof Pitch Termination Heights for Vents Above Flat or Sloped RoofsFireplace Installation Installing GAS Piping to Fireplace / Burner System LocationCheck GAS Type Only persons licensed to work with Gas piping may make the necessaryGas connections to this appliance Electrical Wiring Checking GAS Pressure and Electrical InstallationDo not use open flame to check for Gas leaksRemote Wall Switch Installation Remote Wall Mounted SwitchOptional FAN/BLOWER System Optional FAN/BLOWER System Junction Box Wiring DiagramBlower Access Plates Glass Frame Removal Glass RemovalFinal Installation BRICK, Light BULB, and Lens PlacementRock Wool Placement Burner Grate Assembly Step LOG PlacementFinal Installation Operating Instructions MILLI-VOLT Leak TestingWhat to do if YOU Smell GAS Initial LightingApproved Leak Testing Method Main Burner Switch Lighting the BurnerPilot Position BURNER, Pilot and Control Compartment Cleaning and MaintenancePilot Flame BurnerGlass Door Vent SystemLogs Rock WoolTroubleshooting Symptom Possible Cause ActionStanding Pilot Ignition Troubleshooting Firebox Components and Accessories Illustrated Parts ListsDescription Qty Standing Pilot Millivolt Control KHLDV400NV KHLDV400PV KHLDV500NV KHLDV500PV Vent Components for 5 X Illustrated Parts ListLogs Special Requirements Special Requirements 73D0024 73D0024 73D0024 73D0024 Lifetime Warranty Five Year WarrantyBasic Warranty

KHLDV SERIES specifications

The Monessen Hearth KHLDV Series is a standout line of direct vent gas fireplaces designed to elevate both the aesthetics and functionality of residential spaces. Distinguished by their contemporary design and impressive heating capabilities, these units cater to homeowners seeking a modern solution for efficient warmth and ambiance.

One of the primary features of the KHLDV Series is its versatile design options. Available in various sizes and styles, these fireplaces can seamlessly integrate into diverse interior décor themes. The clean face design allows for a wide viewing area of the flames, providing an unobstructed view that enhances the overall experience. The elegant finish options, ranging from sleek black to decorative trim, make it easy for consumers to customize their unit to suit their personal style.

The KHLDV Series is also noted for its advanced heating technology. Utilizing direct venting, it ensures efficient operation while minimizing heat loss. This technology allows the fireplace to draw air from outside for combustion, which not only improves energy efficiency but also maintains optimal indoor air quality by preventing the depletion of oxygen in the living area. The balanced flue design further ensures that harmful gases are vented safely outside, giving homeowners peace of mind.

Control is another significant advantage of the KHLDV Series. Equipped with a multi-function remote control system, users can easily adjust the flame height and heat output to achieve their desired ambiance and comfort levels. This intuitive control system enhances the overall user experience, allowing homeowners to create a cozy environment with minimal effort.

Safety features are also a crucial consideration in the design of the KHLDV Series. Each unit comes with a built-in safety pilot system that ensures the fireplace operates reliably and safely, providing an additional layer of security for families. The high-quality materials used in construction further enhance durability, ensuring that the fireplace can withstand the test of time.

In summary, the Monessen Hearth KHLDV Series is a perfect blend of style, efficiency, and safety. With its sleek design, advanced heating technology, user-friendly control, and robust safety features, this series transforms any living space into a warm and inviting sanctuary. Ideal for modern homes, the KHLDV Series stands out as a compelling choice for those looking to enhance their home with a functional and elegant fireplace.